Removing the cover from the vaporiser tank
1. CAUTION! Check if the mains connection
has been disconnected and close the water
supply. Allow the steam generator to cool
for approx. 30–45 minutes. Wear gloves.
2. Unplug the connections (A) from the hea-
ting coils.
3. Mark the lines so that you maintain the cor-
rect sequence when you plug them back in.
4. CAUTION! The descaler hose has descaler
residue. Wear gloves. Remove the descaler
hose and place it in a bucket so that the de-
scaler can drain.
5. Remove the descaler hose (B) and place it
in a bucket so that the descaler can drain.
6. Remove the capillary tube sensor (C) from
the intake pipe.
7. Carefully lay the capillary tube sensor to the
side.
8. The capillary tube may not be kinked, jam-
med, or damaged. The capillary tube sensor
may not be damaged.
9. Loosen the 2 hose clamps (D) at the double
valve and remove the flexible water supply
lines.
10. Loosen the steam supply (E) at the housing
floor.
11. Loosen the 2 screws (F) for the steam pipe
on the carrier plate.
10.3 Dismantle the vaporiser tank with heating spirals
If necessary, the vaporiser tank can be opened as follows:
G
D
E
F
F
12.
Disconnect the connection line (G) of the
water level control on the main board („Wa-
terlevel“ terminal).
A
A
B
A