27
EN
5.6 Mounting the steam pipe
Necessary steps
•
Connecting the steam supply to the housing floor
Ha tools:
•
Ø 35 mm pipe, heat-resistant up to 110°C
•
T-piece: 1 1/4’’ for steam supply, 3/8’’ for essence nozzle
•
Silicone, heat-resistant up to 110°C
•
Spanner 19, 36, 46, 50
NOTICE
Contamination of and damage to the vaporiser tank
After descaling, and once the vaporiser tank is drained, a suction effect can occur, during which
residue of essences from the steam supply can enter the tank.
Oils in the essences, even in small quantities, can create a thick layer of foam on the water‘s surface.
The water level sensor cannot differentiate foam from water, and the actual water level lies signifi-
cantly below the layer of foam. This could cause overheating and an emergency shutdown, which
can lead to various types of damage, e.g. failure of the safety temperature limiter.
Furthermore, the foam can be drawn into the steam supply together with the water from the tank.
The vaporiser tank is drained empty in just a few minutes from this suction. This can cause serious
overheating.
•
Connect the essence line so that it is not possible for condensate with essence to flow back into
the vaporiser tank.
•
Connect the essence line as close to the steam emission nozzle/cabin as possible.