Mounting
The following distances must be observed:
3.1.2
Mounting the steam generator
The steam generator is mounted on the wall with four (4) retaining screws
and suitable anchors. Note that the steam generator may vibrate slightly
when the water boils. Ensure that you have sufficient hardware for securing
it if you do not use the supplied screws and anchors.
Necessary steps:
Ha tools:
0.5 m tube with screw, 3/4” female thread
Four 5 x 40 screws; four F6 anchors (included in scope of delivery)
6 mm drill
Phillips screwdriver
Recommendation: 2 persons to mount the steam generator
Preparing for installation
1
NOTICE Ensure that the holes are aligned vertically and horizontally.
Use a spirit level.
Drill two (2) holes above and below.
See
2
Insert the anchors and screw in the top two screws.
Allow the screws to protrude approx. 3 mm so you can hang the
steam generator on them.
Distance between drill holes
Horizontal: 418 mm
Vertical: 240 mm
Distance (side) left and right to the walls
250 mm
Top
Min. 250 mm
Bottom
Approx. 1000 mm