background image

6

GB

Electrical connection 

Using the above-mentioned wiring diagram 

and the information on the wiring circuit ad-

hered to the respective control system, your 

electrician will be able to connect the system 

without further instructions.

Please note that, for safety reasons, power ca-

bles may not be laid visibly on the interior walls 

of the cabin. Most sauna cabins have empty 

ducts fitted into the wall element with the air 

intake.
If no empty ducts are available in your cabin, 

drill a sufficiently sized hole in the cabin wall 

directly next to the place where the cable exits 

the sauna heater and guide this cable outside 

through the hole to the control unit. The cable, 

and all other connecting cables (mains power 

cables and cabin lighting), should be instal-

led in installation ducts or also be protected 

against damage on the outside of the cabin e.g. 

by laying them in installation pipes or attaching 

wood cover strips.
The sauna heater may only be used in combina-

tion with a protective cover or S-guard system 

if operated by remote control*

*Remote control = Setting, control and/or regulation of 

the device by means of commands entered when the de-

vice is out of sight. Telecommunication, sound technology 

or bus systems can be used.

Caution!

Dear Customer, 

In compliance with the valid regu-

lations, only certified electricians 

may connect the sauna heater 

and the sauna control system to 

the mains power supply. Please 

note that you must provide a copy 

of the invoice from the electrical 

company who installed the sauna 

in case of a warranty claim.

tion and instructions provided by 

the cabin manufacturer.

• 

 Please take precautions 

when cleaning components with 

sharp edges.

• 

Upright heaters need to be fitted 

on site with elements that pre-

vent them from overturning.

• 

 Attention:

 Pour the infusi-

on water only on the sauna rocks 

and never anywhere else.

• 

When using your sauna in a 

dry Finnish mode never add sau-

na essences or place any herbs 

into the vaporizer holder for es-

sences/herbs. 

Risk of fire!

• 

 Never add more essences or 

volatile oils than advised on the 

packaging. Never use alcohol or 

undiluted concentrates. Caution! 

Fire hazard!

Содержание Mythos S34

Страница 1: ...1 D MADE IN GERMANY Mythos S34 S45 print no 29344483en 05 13 GB Installation and operation manual sauna heater Image above shows optional equipment...

Страница 2: ...S45 Vapor 7 Installation Scope of delivery 8 Specifications 8 Minimum clearances 8 Heater foot sealing installation 9 Cable connections 9 Installation of Cubic stones 9 Dry Finnish sauna operation 10...

Страница 3: ...ed the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please o...

Страница 4: ...resin and untreated materials e g spruce Only one sauna heater with the required heating output may be installed in the sauna cabin Please provide air intake and vent openings in each sauna cabin The...

Страница 5: ...a flexi ble metal tube connected to the equipment grounding conductor Please see the table for the mi nimum cross section of the con nection cable and the suitable cabin size in relation to the power...

Страница 6: ...tion with a protective cover or S guard system if operated by remote control Remote control Setting control and or regulation of the device by means of commands entered when the de vice is out of sig...

Страница 7: ...ater Connection power extension heater Connection controller power extension unit 7 5 kW 3N AC 50 Hz 400 V 3 x 16 5 x 2 5 5 x 1 5 9 0 kW 12 0 kW 3 x 16 5 x 2 5 5 x 1 5 4 x 1 5 15 0 kW All cross sectio...

Страница 8: ...trol unit ECON EMOTEC 4 5 3 optional 5 Netz Main LSG 5 5 5 4 5 4 Saunasteuerger t control unit ECON EMOTEC 3 optional 4 Netz Main 7 5 9 kW 12 15 kW Vaporizer power Electrical connection Vaporizer wate...

Страница 9: ...5 or 9 0 kW Mythos S45 12 0 or15 0 kW depending in the model Height 840 mm Width S35 420 mm S45 500 mm Depth 370 mm Stone filling S35 35 kg S45 45 kg Leakage current max 0 75 mA per kW heating power S...

Страница 10: ...ards and shall be drawn along the foot to the sauna controller LSG unit Illust 4 Illust 3 Mythos S45 Mythos S35 Optional Cubic stone sets For Mythos S35 item 94 5520 For Mythos S45 item 94 5521 The op...

Страница 11: ...an indicated on the pack Never use alcohol or undiluted infusi ons Danger There is a risk of fire Attention Pour the infusion water only on the sauna rocks and never anywhere else When using your saun...

Страница 12: ...tones will re heat suffici ently again Never add more essences or volatile oils than advised on the pa ckaging Never use alcohol or un diluted concentrates Caution Fire hazard All sauna heating units...

Страница 13: ...ical units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the surrounding air...

Страница 14: ...mber and model name with detailed description of the fault This guarantee covers defective parts and la bour but not the defects caused by wear and tear In case of complaint please return the equip me...

Страница 15: ...individual case and try for immedi ate and customer friend ly solution For economic returns within Germany you will get an RMA number from the manufacturer All returns have to be in the original pack...

Отзывы: