15
GB
Technical data
Voltage: 230 V 1N 50 Hz
Power input: 300 W
Height: 550 mm
Width: 184 mm
Depth: 65 mm
Weight: approx. 2 kg
radiator front and
side view
cut-out in the wall
Important notice:
Remove the transport stabilisers from the infra-
red ceramic emitter.
Take off the covering grille. Cut open the cable
binds (with side-cutting pliers). Take care not
to damage the ceramic emitter. Remove the U
plates from the sides and discard them.
Fig. 1
Electrical connection
Infrared radia-
tors
Plug adaptor
300 W
300 W
300 W
300 W
300 W
To control
unit
The connection cables should be fed through
concealed ducts or protected from damage in
other appropriate ways.
In order to facilitate the connection of several
IRS3 radiators to one power supply line from
control unit we recommend the optional plug
adaptor (item 942046 - with link cable, item
944960 - adaptor without cable). One adaptor
allows to bundle up to 5 IRS3 radiators.
Connect the IR radiator to the control unit. By
multiple radiators the connection example is
shown on the Fig. 3.
IR radiators feature 3 m pre-mounted cable
with the special plug to facilitate connection.
!
CAUTION!
If the connection cable of this appliance
becomes damaged, it must be replaced by
a special connection cable which can be ob-
tained from the manufacturer or customer
service department.
Fig. 2
Fig. 3
165
550
184
65
530