stallation  or  set-up  in  a  niche,  under  a 
bench or under a sloping roof.

• 

Do not put the sauna heater into operation 
when the air intake is closed.

• 

The cabin lighting and the corresponding 
installation  must  correspond  with  the 
"splash  protected"  version  in  accordance 
with  DIN  EN VDE  0100 T  703. Therefore, 
only VDE-tested sauna light with max. 40 
Watt may be installed in connection with 
the sauna heater. 

• 

  Only  a  locally  certifi ed  electrician 

may  connect  the  sauna  facility  (sauna 
heater, control unit, lighting etc.) to a fi xed 
mains connection.

• 

All electrical installations and all connec-
tion lines that are installed inside the cab-
in must be suitable for an ambient tem-
perature of at least 170 °C. If single-wire 
cables are used as connection lines, they 
must be protected using a fl exible metal 
tube connected to the equipment ground-
ing conductor. Please see the table for the 
minimum cross-section of the connection 
cable and the suitable cabin size in rela-
tion to the power input in kW.

• 

When installing the sauna heater, please 
ensure  that  the  vertical  clearance  be-
tween  the  sauna  heater  upper  edge  and 
the  sauna  ceiling  is  maintained.  Please 
see  also  the  dimensions  diagram  for  the 
clearance between the lower edge of the 

sauna  heater  and  the  fl oor.  On  heaters 
with  bases,  this  clearance  is  maintained 
via the base or legs of the device. 

• 

Please always ensure that the sauna heat-
er  is  never  placed  on  fl ooring  made  of 
fl ammable  material  (wood,  plastic  fl oor-
ing  etc).  Ceramic  tiles  are  recommended 
as fl oor materials.

• 

Floor heating in the sauna cabin increases 
the surface temperature of the fl ooring.

• 

Please  see  the  dimensions  information 
for  the  respective  sauna  heater  for  the 
clearance  between  the  heater  protective 
grating or the bench and other fl ammable 
materials.  The  heater  protective  grating 
must roughly accord with the front height 
of the sauna heater.

• 

Please  also  observe  the  information  and 
instructions provided by the cabin manu-
facturer.

• 

  Please  take  precautions  when 

cleaning components with sharp edges.

• 

Upright heaters need to be fi tted on site 
with  elements  that  prevent  them  from 
overturning.

• 

 Attention:

 Pour the infusion water 

only  on  the  sauna  rocks  and  never  any-
where else.

• 

When  using  your  sauna  in  a  dry 

Finnish mode never add sauna essences or 

Содержание Finnrock 94.5654

Страница 1: ...INNOVATIVE S AU NA TECH NO LO G Y MADE IN GERMANY IP x4 GB Finnrock Druck Nr 29344535en 45 15 Installation and operation manual Sauna heater...

Страница 2: ...lectrical connection example 7 Internal wiring diagram 7 Technical data 8 Installation of the Finnrock heater 9 Minimum clearances 9 Sauna rocks 10 Maintenance and care 10 Advice for electrical instal...

Страница 3: ...pped the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please...

Страница 4: ...resin untreatedmaterials e g spruce Only a sauna heater with the appropriate power output may be installed in the sau na cabin Please provide air intake and vent ope nings in each sauna cabin The air...

Страница 5: ...hat the vertical clearance be tween the sauna heater upper edge and the sauna ceiling is maintained Please see also the dimensions diagram for the clearance between the lower edge of the sauna heater...

Страница 6: ...hat for safety reasons power ca bles may not be laid visibly on the interior walls of the cabin Most sauna cabins have empty ducts fitted into the wall element with the air intake If no empty ducts ar...

Страница 7: ...ier de commande Saunaheizger t Sauna heater Po le de sauna 5 5 Netz Mains R seau 7 5 9 0 kW 12 kW L1 L2 L3 N Sensor Limiter S1 LSG U V W WB WM N 400 V AC 3N 4 3 2 1 Sensor 4 3 2 1 U V W N L1 L2 L3 N S...

Страница 8: ...ion LSG unit heater 94 5663 7 5 kW 3 x 16 A 5 x 2 5 mm 5 x 1 5 mm 94 5654 9 0 kW 94 5664 12 0 kW 3 x 16 A 5 x 2 5 mm 4 x 1 5 mm 5 x 1 5 mm All cross sections of connection cables are minimum diameters...

Страница 9: ...ng hand ling as the inner parts may have sharp edges Make sure that the heater stands reliably on all four feet Do not load the rocks until the heater is at its final position Make sure to observe the...

Страница 10: ...stones will re heat suffici ently again Never add more essences or volatile oils than advised on the packaging Never use alcohol or undiluted concentrates Cau tion Fire hazard All sauna heating units...

Страница 11: ...l units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the surrounding air It...

Страница 12: ...el name with detailed description of the fault This guarantee covers defective parts and labour but not the defects caused by wear and tear In case of complaint please return the equip ment in its ori...

Страница 13: ...p ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall accept no liability for damage incu...

Отзывы: