InfraStyle / InfraStyle i - Installation Instructions
57
Installation
5.3 Connection diagram
The relay box is connected with a mains lead to the 230-V supply and fused
separately with 16 A. At minimum, a 16-A cut-out with c characteristic
must be used for fuse protection.
Connection example
To prevent overheating, install only infrared emitters or heating foils that
are designed and installed in such a way that they do not pose a fire hazard
when the unit is operated as intended. Alternately, infrared emitters or
heating foils with overheat protection as per EN 60335-2-53 may be used.
The power supply must be mounted separately and outside of the cabin. It
may not be mounted in the relay box.
IR-Emitter 1
IR-Emitter 2
IR-Emitter 3
230 V AC 50 Hz
230 V AC 50 Hz
N
N
L
IR-1
IR-2
L
LIGHT
MAINS IR-3
L
N
N
N
L
L
Platine
STB
Saunabus
Sensor
24V DC
24V DC