E90-803-001-005-01 – Rev 4
- 7 -
Burner installation
Mounting onto the appliance
The burner is mounted onto the appliance by means of a removable 6-bolt
flange.
The gasket needs to be put in place before the flange is fixed onto the
appliance. The burner tube is then inserted through the centre hole after
fitting the O-ring over the the blast tube.
With the burner rotated a few degrees clockwise the flange bolts will pass
through the locating holes. When the burner is twisted into position the top
bolt can then be tightened to secure the burner. If necessary the lower screw
can be adjusted to give a more secure fixing.
If required the burner can be mounted in any position. It is important though
to ensure that the solenoid valve on the oil pump is not inclined below
horizontal.
Electrical connection
The electrical connections to this burner must be carried out by a suitably qualified engineer.
All Electrical connections to the burner must be carried out in accordance with all current applicable IEE Wiring
Regulations.
All connections should be made according to the wiring diagram shown on the supplementary page.
The burner is fitted with a 7-pin socket pre-wired into the burner.
Fuel supply
The burner is usually supplied for two-pipe operation but if required can be converted for a one-pipe gravity
system (details elsewhere in this manual). When used in conjunction with a gravity feed supply the inlet pressure
to the pump MUST NOT exceed 2 bar.
When using a two-pipe system the return line has to be fed back into the tank. Alternatively, a de-aeration device
could be incorporated for ease of installation.
Oil lines must be completely air-tight and constructed in accordance with current standards.
The final connection to the oil pump must be made with the flexible oil line provided.
Air supply
Combustion air and ventilation requirements are detailed in BS5410:Part1. It requires that combustion air must
be provided through purpose-made non-closeable openings, having a total free area of 550mm2 per kW of the
appliance maximum output rating above 5kW.