Install Rear Cover
After pan is levelled, water supply and waste are connected, and the pan is tested and
visually inspected for any leaks, install the rear cover to plug the inspection hole.
Apply silicone sealant around the rear cover to create a thorough seal between the rear cover,
pan and floor. Ensure no gap is left that can let any moisture to get through inside the base of
the pan.
Water Inlet Connection
Flush the water supply line to ensure the line is clear,
and connect water supply to the inlet connection of
the cistern.
The inlet connection requires sealing with a washer.
For hard pipe connection with compression nuts or
thread sealing, use a loose nut extension fitting -
IFOS-009 (Optional).
The inlet connection is flexible. Hold the inlet thread
on the hex with a spanner when making the thread
connection.
Do not use the toilet until the silicone bed has cured.