background image

MAINTENANCE

TROUBLESHOOTING

CAUTION

REFRIGERATION SYSTEM

 - The entire refrigeration system is hermetically sealed. 

Should the system fail to operate, contact the manufacturer immediately. 

 

Note: tampering with the refrigeration system in any way may void warranty.

 

 

WATER TEMPERATURE CONTROL SCREW

 - Located internally on the shelf, 

 

has 

been factory set to provide chilled water at approx. 5O

C to 10

OC.  

 

(Thermostat part no: 372540)

 

BUBBLER STREAM ADJUSTMENT

Operate fountain and determine if the water stream height is satisfactory.
1. If the water stream needs to be reset, the hex cover nut must be unscrewed 

from the bubbler body using a suitable spanner. The nut and push button can be 

removed to reveal the top of the spring cartridge and the cartridge locking ring.
2. Locate the flow adjustment screw in the top of the cartridge. While pressing 

the  cartridge  to  fully  on  position,  using  a  small  slotted  screwdriver,  screw  the 

adjustment screw in to reduce stream height, or out to increase stream height.
3. Replace the push button and hex cover nut and tighten.
4. Re-test fountain for correct operation.

Every 6 months or periodically as required, the appliance and its 

surronding area should be inspected for water leaks, the bubblers 

should be tested for correct operation and external panels  should 

be  given  a  light  wipedown.  Filters  if  used  should  be  replaced, 

depending  on  usage.  Water  storage  tank  should  be  purged  by 

running the tap for 5 minutes, before installing a new filter.

Every 12 months or as required, the bubbler stream height should 

be re-adjusted. If the bubbler or carafe filler is leaking, the cartridge 

or carafe filler should be replaced.

The internal condenser and fans should be kept free of dust/lint. It 

should be checked periodically and cleaned with a brush or vacuum 

cleaner. Water cooler must be disconnected from the power supply 

before following this procedure.

CLEANING

Enware Product should be cleaned with a soft damp cloth using 

only mild liquid detergent or soap and water. Do not use cleaning 

agents containing a corrosive acid, scouring agent or solvent 

chemicals. Do not use cream cleaners, as they are abrasive. Epoxy 

coated surfaces should only be cleaned with a cloth and clear water 

or mild detergent. Use of unsuitable cleaning agents may damage 

the surface. Any damage caused in this way will not be covered by 

warranty. 

Cleaning is not required for internal components of the appliance. 

The appliance must not be cleaned by a water jet.

•  Mains Power Electrical Components. 

For  the  purpose  of 

safety and hygiene, access to the internal components of 

this appliance is restricted to persons having knowledge and 

practical experience of the appliance. 

• 

Ensure the electrical supply is turned off, before taking the 

front panel off to access internal components.

•  If the power supply cord is damaged, it must be replaced by 

the manufacturer, its service agent or a qualified electrician 

in order to avoid a hazard. 

• 

In order to avoid a hazard due to inadvertent resetting of the 

thermal cutout, this appliance must not be supplied through 

an external switching device, such as a timer, or connected 

to a circuit  that is regularly switched on and off by the utility.

• 

Do not damage the refrigerant circuit. Care should be taken 

not  to  puncture  refrigeration  system  lines.  Some  lines 

contain gas under high pressure.

• 

Keep ventilation openings, in the appliance enclosure or in 

the built-in structure, clear of obstruction.

•  Do not use mechanical devices or other means to accelerate 

the defrosting process, other than those recommended by 

the manufacturer.

• 

If  freezing  occurs,  do  not  operate  the  appliance,  until 

ambient temperatures is again above 0°C and frozen unit 

has completely thawed.

COMPONENTS

PROBLEM

CAUSE

RECTIFICATION

No water at outlets

Water not connected or turned off

Connect and turn on water supply

Water frozen

Adjust water temperature control on thermostat to higher setting. Do 

not operate the appliance, until ambient temperature is again above 

0°C and frozen unit has completely thawed.

Water not cooled

Power is not connected

Turn power supply on

Fan ventilation not adequate

Ensure there is gap behind back of chiller to allow air flow from vents

Temperature setting too high

Adjust water temperature control on thermostat to lower setting

Poor water flow at 

outlets

Bubbler stream is not adjusted

Adjust bubbler stream

Carafe filler handle is too loose

Adjust carafe filler adjusting nut and handle

Carbon filter is blocked

Replace carbon filter

Water leaks at 

outlets

Bubbler cartridge is damaged

Replace bubbler cartridge. Ensure water pressure is below 500kPa

Carafe filler handle is too tight

Adjust carafe filler nut and handle

Water tastes foul

Carbon filter has been contaminated Replace carbon filter

Water in tank is stale

Purge water in tank by running the bubbler for 5 minutes

HEX COVER NUT

PUSH BUTTON

CARTRIDGE 

LOCKING RING

(RETAINING NUT)

CARTRIDGE

(BUB294)

SPOUT ASSEMBLY

BODY

FLOW

ADJUSTMENT