MAINTENANCE
TROUBLESHOOTING
CAUTION
REFRIGERATION SYSTEM
- The entire refrigeration system is hermetically sealed.
Should the system fail to operate, contact the manufacturer immediately.
Note: tampering with the refrigeration system in any way may void warranty.
WATER TEMPERATURE CONTROL SCREW
- Located internally on the shelf,
has
been factory set to provide chilled water at approx. 5O
C to 10
OC.
(Thermostat part no: 372540)
BUBBLER STREAM ADJUSTMENT
Operate fountain and determine if the water stream height is satisfactory.
1. If the water stream needs to be reset, the hex cover nut must be unscrewed
from the bubbler body using a suitable spanner. The nut and push button can be
removed to reveal the top of the spring cartridge and the cartridge locking ring.
2. Locate the flow adjustment screw in the top of the cartridge. While pressing
the cartridge to fully on position, using a small slotted screwdriver, screw the
adjustment screw in to reduce stream height, or out to increase stream height.
3. Replace the push button and hex cover nut and tighten.
4. Re-test fountain for correct operation.
Every 6 months or periodically as required, the appliance and its
surronding area should be inspected for water leaks, the bubblers
should be tested for correct operation and external panels should
be given a light wipedown. Filters if used should be replaced,
depending on usage. Water storage tank should be purged by
running the tap for 5 minutes, before installing a new filter.
Every 12 months or as required, the bubbler stream height should
be re-adjusted. If the bubbler or carafe filler is leaking, the cartridge
or carafe filler should be replaced.
The internal condenser and fans should be kept free of dust/lint. It
should be checked periodically and cleaned with a brush or vacuum
cleaner. Water cooler must be disconnected from the power supply
before following this procedure.
CLEANING
Enware Product should be cleaned with a soft damp cloth using
only mild liquid detergent or soap and water. Do not use cleaning
agents containing a corrosive acid, scouring agent or solvent
chemicals. Do not use cream cleaners, as they are abrasive. Epoxy
coated surfaces should only be cleaned with a cloth and clear water
or mild detergent. Use of unsuitable cleaning agents may damage
the surface. Any damage caused in this way will not be covered by
warranty.
Cleaning is not required for internal components of the appliance.
The appliance must not be cleaned by a water jet.
• Mains Power Electrical Components.
For the purpose of
safety and hygiene, access to the internal components of
this appliance is restricted to persons having knowledge and
practical experience of the appliance.
•
Ensure the electrical supply is turned off, before taking the
front panel off to access internal components.
• If the power supply cord is damaged, it must be replaced by
the manufacturer, its service agent or a qualified electrician
in order to avoid a hazard.
•
In order to avoid a hazard due to inadvertent resetting of the
thermal cutout, this appliance must not be supplied through
an external switching device, such as a timer, or connected
to a circuit that is regularly switched on and off by the utility.
•
Do not damage the refrigerant circuit. Care should be taken
not to puncture refrigeration system lines. Some lines
contain gas under high pressure.
•
Keep ventilation openings, in the appliance enclosure or in
the built-in structure, clear of obstruction.
• Do not use mechanical devices or other means to accelerate
the defrosting process, other than those recommended by
the manufacturer.
•
If freezing occurs, do not operate the appliance, until
ambient temperatures is again above 0°C and frozen unit
has completely thawed.
COMPONENTS
PROBLEM
CAUSE
RECTIFICATION
No water at outlets
Water not connected or turned off
Connect and turn on water supply
Water frozen
Adjust water temperature control on thermostat to higher setting. Do
not operate the appliance, until ambient temperature is again above
0°C and frozen unit has completely thawed.
Water not cooled
Power is not connected
Turn power supply on
Fan ventilation not adequate
Ensure there is gap behind back of chiller to allow air flow from vents
Temperature setting too high
Adjust water temperature control on thermostat to lower setting
Poor water flow at
outlets
Bubbler stream is not adjusted
Adjust bubbler stream
Carafe filler handle is too loose
Adjust carafe filler adjusting nut and handle
Carbon filter is blocked
Replace carbon filter
Water leaks at
outlets
Bubbler cartridge is damaged
Replace bubbler cartridge. Ensure water pressure is below 500kPa
Carafe filler handle is too tight
Adjust carafe filler nut and handle
Water tastes foul
Carbon filter has been contaminated Replace carbon filter
Water in tank is stale
Purge water in tank by running the bubbler for 5 minutes
HEX COVER NUT
PUSH BUTTON
CARTRIDGE
LOCKING RING
(RETAINING NUT)
CARTRIDGE
(BUB294)
SPOUT ASSEMBLY
BODY
FLOW
ADJUSTMENT
SCREW
IMAGE 6