ENErgy sAVINg BENEFITs
Your ECO
2
Wall also helps to save energy in the following ways:
Minimum Energy Consumption
Using the latest technology, the units are powered by ultra-low watt motors to achieve low running costs.
Heat Distribution
Warm air accumulates at ceiling level. This air can be up to 7°C higher than the internal air at ground
level. By introducing an air supply, the ECO
2
Wall helps to redistribute heat around the home to further
reduce heating costs.
No need to open windows
To reduce humidity and condensation during the heating season, significant energy loss occurs
by opening windows. The ECO
2
Wall provides fresh, filtered air to the home and reduces humidity
without the need to open windows, saving energy and heat loss.
HEALTH BENEFITs:
Reduces mould spores, a trigger for respiratory problems and allergies
Reduces house dust mite populations by lowering humidity levels - a main trigger for asthma and
allergies
HOW DO I CONTrOL My ECO
2
WALL UNIT?
Standard automatic mode: On auto the flow rate of the unit will be set at the appropriate level for your home
during installation. To enable or disable the heater press the heater enable switch on or off.
WHAT FEATUrEs DOEs My ECO
2
WALL UNIT HAVE?
The intelligent low temperature comfort heater* is designed to temper the air during periods of low external
temperatures. It is capable of holding incoming air temperatures accurately at 10°C. With the function enabled,
the heater may be on 10% of the time, depending on the fan speed setting and only at loft temperatures at
or below 10°C. The unit has an automatic increased airflow setting. This function increases airflow rates per
setting by 10% to deliver additional air into the property at temperatures above 19°C.
*Heater may be omitted on request by the customer.
MAINTENANCE
After 3 years the filter located in the unit must be replaced. Screws located on the edge of the cover must
be removed and the cover loosened and removed. Pull on the foam pad on the side of the unit to remove
the filter. Replace the filter and covers ensuring all duct work is securely in place. Work to be carried out by a
technically competent person. When carrying work out to this unit it should be isolated from the main power
supply at the fuse spur.
HOW MUCH DOEs My ECO
2
WALL UNIT COsT TO rUN?
The ECO
2
Wall is very energy efficient. On a constant medium setting with the heater enabled, the unit will cost
around £30* a year to run. With the heater disabled the unit will cost less than £6* a year.
*Based on an average electricity unit price of 15p.