ATTENTION:  When  the  humidity  rate 
is  above  the  selected  value,  the 
automatic  option  takes  precedence 
over the manual. 
 
Settings 

The settings at manufacture are 60%HR 

for humidity and 1 minute for timer. 

The desired humidity level is selected by 

means of a potentiometer “

P3

” positioned 

on the printed circuit board (fig.8). 

-  To  reduce  the  humidity  setting  turn 

anticlockwise (min.60 %) 

-  To  increase  the  humidity  setting  turn 

clockwise (max. 90 %) 

 

To  set  the  timer,  turn  the  potentiometer 

P2

” on the printed circuit board (fig.8): 

-  To  reduce  the  "run  on"  time,  turn 

anticlockwise (min. 1 minute) 

-  To  increase  the  "run  on"  time,  turn 

clockwise (max: 30 minutes). 

 

Specific recommendations: 

-  If you change the settings of the extract 

fan  you  have  to  handle  the 

potentiometers  in  the  printed  circuit 

board.  These  potentiometers  are 

fragile and must be handled with care. 

-  Do  not  change  the  setting  of  the 

humidity sensor out of the room where 

the fan will be installed. 

-  If  the  humidity  is  always  above  90% 

RH,  the  fan  will  always  run  at  full 

speed. 

-  If  the  humidity  in  the  room  is  always 

less than 60%, the fan will only operate 

on  trickle  speed  when  running  in 

automatic operation. 

 

If the fan never runs on boost: 

-  The setting of the humidity sensor has 

been  set  to  maximum.  Change  the 

setting 

-  The  level  of  humidity  in  the  room  is 

below 60% RH 

 

If the fan always runs at boost 

-  The setting of the humidity sensor has 

been set to the minimum. Change the 

setting 

-  The  level  of  humidity  in  the  room  is 

above 90% RH 

 

ECO dMEV HTP

 

ECO  dMEV  version  similar  to  H  model, 

fitted  with  a  manual  pull cord to operate 

the  boost  when  the  humidity  level  is 

below the set point (fig.6) 

 

When switching the pull cord off, the fan 

will  continue  to operate on  boost  for  the 

time  set  by  the  timer  then  will  revert  to 

trickle  speed,  unless  the  humidity  level 

exceeds the set point. 

 

Maintenance

 

IMPORTANT: 

DISCONNECT 

FROM 

THE 

MAINS 

SUPPLY 

BEFORE 

CARRYING OUT ANY MAINTENANCE  

 

The  extract  fan  only  requires  periodical 

cleaning using a cloth lightly impregnated 

with a soft detergent. 

 

After Sales Service

  

We  recommend  you  not  to  try  to 

dismantle or remove any other parts than 

those mentioned as any tampering would 

automatically  cancel  the  EnviroVent 

guarantee. If you detect any fault, contact 

EnviroVent on 01423 810810. 

 

If you have any problems, please call our 

dedicated Technical Team on 0845 27 27  

810. 

 

All  EnviroVent  products  are  designed  to 

be  recycled  when  they  reach  the  end  of 

their useful life. To save the environment  

and  to  reduce  landfill,  please  call 

EnviroVent on 01423 810810. 

 

EnviroVent  reserves  the  right  to  alter  specifications 

without notice 

Содержание ECO DMEV SELV

Страница 1: ... env1rovent ECO DMEV ECO DMEV SELV Instruction leaflet ...

Страница 2: ...Fig 1 6 7 P2 P3 P1 SW1 1 SW1 2 SW1 3 SW1 4 SW1 5 1 2 3 4 5 ...

Страница 3: ...Fig 2 ...

Страница 4: ...Fig 3 L N J2 GND LS J1 LS N L 17V L N ECO dMEV 230Vac 50 60Hz CT 17 18 230Vac 50 60Hz 0 17V DC ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 5: ...Fig 4 J2 GND LS J1 LS N L 17V CT 17 18 230Vac 50 60Hz L N 230Vac 50 60Hz N L 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 6: ...Fig 5 J2 GND LS J1 LS N L 17V CT 17 18 230Vac 50 60Hz L N 230Vac 50 60Hz N L 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 7: ...Fig 6 L N J2 GND LS J1 LS N L 17V L N 230Vac 50 60Hz CT 17 18 230Vac 50 60Hz 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 8: ...Fig 8 Fig 7 P2 min P3 HR P2 min ...

Страница 9: ...r wall or ceiling mounting and can either extract directly to the outside or through a ducted system see Fig 2 Make a Ø105 mm hole in the wall or ceiling If the unit is to be installed with ducting use a standard Ø100 mm duct Remove the front grille 1 and the protection cover 2 The unit can be mounted on the wall or ceiling using the 4 raw plugs and the screws provided Ensure that there are no obs...

Страница 10: ...en turned off fig 5 Fig 4 shows how to connect the fan with timer through using the same switch as the lighting circuit to allow the fan to be boosted To set the timer turn the potentiometer P2 on the printed circuit board as fig 7 Manufacture setting 1 minute To reduce the run on time turn anticlockwise min 1 minute To increase the run on time turn clockwise max 30 minutes ECO dMEV HT Models prov...

Страница 11: ...midity sensor has been set to maximum Change the setting The level of humidity in the room is below 60 RH If the fan always runs at boost The setting of the humidity sensor has been set to the minimum Change the setting The level of humidity in the room is above 90 RH ECO dMEV HTP ECO dMEV version similar to H model fitted with a manual pull cord to operate the boost when the humidity level is bel...

Страница 12: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com info envirovent com Ref 9023025202 ...

Отзывы: