The ECO dMEV may also operate at high 

speed  that  is  activated  by:  an  external 

switch  live  or  light  switch  (

S,  T  and  HT 

versions

)  an  integral  humidity  sensor 

(

HT  and  HTP  versions

)  or  an  internal 

pull cord switch (

HTP version

). 

 

ECO dMEV S

 

The  ECO  dMEV  S  can  operate  in  two 

modes: 

1. Continuous operation on trickle setting 

only (Fig. 3). Once the air volume is set 

the fan is connected to the mains and 

the unit will operate continuously at this 

air volume. 

2. Continuous  operation  on  trickle  with 

the ability to boost on high speed. 

The  ECO  dMEV  is  connected  to  an 

external switch or light switch. 

When  the  switch  is  pressed,  the  fan 

operates  on  full  speed  (not  constant) 

until the switch is turned off (light off): 

Fig.4- Wiring diagram to boost the fan 

with the light switch. 

Fig.5- Wiring diagram to  boost the fan 

with a separate switch 

 
ECO dMEV T

 

This model is provided with an adjustable 

over-run  timer.  The  timer  allows  the  fan 

to  continue  to  operate  for  the  selected 

period  after  the  switch  has  been  turned 

off (fig.5). 

 

Fig.4 shows how to connect the fan with 

timer  through  using  the  same  switch  as 

the  lighting  circuit  to  allow  the  fan to be 

boosted. 

 

To  set  the  timer,  turn  the  potentiometer 

“P2”

 on the printed circuit board as (fig. 

7). 

-  Manufacture setting:1 minute 

-  To  reduce  the  "run  on"  time,  turn 

anticlockwise (min: 1 minute) 

-  To  increase  the  "run  on"  time,  turn 

clockwise (max: 30 minutes). 

 

ECO dMEV HT

 

Models  provided  with  an  electronic 

humidity  sensor  which  can  be  adjusted 

from 60% to 90 % RH (relative humidity) 

and  with  a  timer,  adjustable  between  1 

and 30 minutes.  

 

Operation 

Case 

1: Automatic operation (fig.3) 

In  automatic  operation,  the  extract  fan 

operates  continuously  on  the  trickle 

setting speed. When the humidity level in 

the room is higher than the set level the 

fan  will  boost  to  high  speed.  When  the 

humidity  drops  below  the  selected  level 

and  after  the  selected  period  set  on  the 

timer  the  fan  automatically  returns  to 

trickle. 

 

Case 

2: Automatic operation as in case 1 

with  the  facility  to  override  the  humidity 

sensor  by  means  of  an  external  switch 

(fig.5)  or  light  switch  (fig.4),  when  the 

humidity  level  in  the  room  is  lower  than 

the  selected  level.    In  this  case,  the 

extract  fan  continues  to  operate  for  the 

selected period set on the timer after the 

light switch has been turned off. 

 

Содержание ECO DMEV SELV

Страница 1: ... env1rovent ECO DMEV ECO DMEV SELV Instruction leaflet ...

Страница 2: ...Fig 1 6 7 P2 P3 P1 SW1 1 SW1 2 SW1 3 SW1 4 SW1 5 1 2 3 4 5 ...

Страница 3: ...Fig 2 ...

Страница 4: ...Fig 3 L N J2 GND LS J1 LS N L 17V L N ECO dMEV 230Vac 50 60Hz CT 17 18 230Vac 50 60Hz 0 17V DC ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 5: ...Fig 4 J2 GND LS J1 LS N L 17V CT 17 18 230Vac 50 60Hz L N 230Vac 50 60Hz N L 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 6: ...Fig 5 J2 GND LS J1 LS N L 17V CT 17 18 230Vac 50 60Hz L N 230Vac 50 60Hz N L 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 7: ...Fig 6 L N J2 GND LS J1 LS N L 17V L N 230Vac 50 60Hz CT 17 18 230Vac 50 60Hz 0 17V DC ECO dMEV ECO dMEV SELV TIME DELAY FUSE 125 mA MAX ...

Страница 8: ...Fig 8 Fig 7 P2 min P3 HR P2 min ...

Страница 9: ...r wall or ceiling mounting and can either extract directly to the outside or through a ducted system see Fig 2 Make a Ø105 mm hole in the wall or ceiling If the unit is to be installed with ducting use a standard Ø100 mm duct Remove the front grille 1 and the protection cover 2 The unit can be mounted on the wall or ceiling using the 4 raw plugs and the screws provided Ensure that there are no obs...

Страница 10: ...en turned off fig 5 Fig 4 shows how to connect the fan with timer through using the same switch as the lighting circuit to allow the fan to be boosted To set the timer turn the potentiometer P2 on the printed circuit board as fig 7 Manufacture setting 1 minute To reduce the run on time turn anticlockwise min 1 minute To increase the run on time turn clockwise max 30 minutes ECO dMEV HT Models prov...

Страница 11: ...midity sensor has been set to maximum Change the setting The level of humidity in the room is below 60 RH If the fan always runs at boost The setting of the humidity sensor has been set to the minimum Change the setting The level of humidity in the room is above 90 RH ECO dMEV HTP ECO dMEV version similar to H model fitted with a manual pull cord to operate the boost when the humidity level is bel...

Страница 12: ...EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 www envirovent com info envirovent com Ref 9023025202 ...

Отзывы: