ECO DMEV HTP LC
ECO dMEV LC version similar to
HT
model, fi tted with an internal pull
cord switch to operate the boost when
the humidity level is below the set
point (fi g.5)
When switching off the internal pull
cord switch, the fan continues to
operate on boost for the time set by
the timer, then runs on trickle speed,
unless the humidity level exceeds the
set point.
ECO DMEV DT LC
Models provided with a PIR (passive
infra-red) detector (movement detec-
ted with a maximum distance of 4 me-
tres) and with an adjustable “run on”
timer (1 to 30 minutes).
The selection of the run on time is
done with the dip-switches 6 and 7:
setting between 1, 5, 15 and 30 mi-
nutes:
1. Continuous operation:
The extractor operates conti-
nuously at the setting trickle
speed. When the extractor detects
a movement the fan is boosted to
high speed during the selected pe-
riod set by the over-run timer and
then automatically returns to tric-
kle speed (fi g.3).
2. Intermittent operation:
The unit starts automatically when
a movement is detected and the
unit continues to operate for the
selected period set on the over-run
timer (fi g.3).
FACTORY SETTINGS:
Interval function: OFF
Interval time: 4h
Humidity sensor: 60%HR
Timer: 1 minute
Start-up timer function: OFF
Continuous operation: ON
MAINTENANCE
IMPORTANT:
DISCONNECT FROM
THE MAINS SUPPLY BEFORE CARR-
YING OUT ANY MAINTENANCE
The ECO dMEV extract fan is supplied
with a plastic fi lter.
Performance depends on cleaning
frequency and thus we recommend
cleaning, minimum every two mon-
ths, in accordance with fi g 1a.
The ECO dMEV extract fan must
always be operated with the fi lter fi -
tted.Using the extract fan without the
fi lter invalidates the warranty.
The external surfac e of the fan only
requires periodical cleaning using a
cloth lightly impregnated with a soft
detergent.