25
Chapter 4- System Specifications
Size
18.5 x 14.25 x 8.25 in. (470 x 362 x 210 mm).
Weight
19 lbs. (8.6 kg) including battery.
Well Diameter:
2 inch minimum.
Max Pumping rate
Approximately 0.5 g.p.m. (1.9 L./min.) Of low viscosity
NAPL..
Minimum skimming
thickness
0" (will pump some water in this condition).
Pumping head
50 ft. (15.24 m) standard unit. 100 ft (30.48 m) optional.
Pumping time
1 hour continuous pumping per battery charge - approx. 35
gal. (133 L.) of low viscosity NAPL.
Viscosity ranges
The
pump handles water and most hydrocarbons, “floaters
(LNAPLS) or “sinkers” (DNAPLS)- viscosities up to 10 cp
Battery
12 V dc, 5 Amp-hours, sealed lead acid battery. (We
recommend a second battery for a backup on site.)
Battery charger
Optional accessory cigarette lighter socket cable for
charging between sites.
Optional accessory car battery cable with alligator clips for
charging on site.
Probe holder
Holds probe when not in use. Prevents dripping.
Operating temperature
0º to 130º F ambient temperature (-18º to 55º C).
Envirotecnics
Tel: +34 872 080 542