8
CAUTION:
Allow for a gentle curve when using flexible connections to avoid a rigid connection.
Support inlet and outlet plumbing in some manner (use pipe hangers) to keep the weight off of the
valve fittings.
WARNING:
If making any soldered copper connections:
no heat, Do all sweat soldering before connecting pipes to valve to avoid damage to internal parts.
WARNING:
Any pressure on the system exceeding, surging or spiking above 75 psi and any negative pressure
due to vacuum break voids the warranty.**
**
An operating pressure reducing valve (PRV) may be required on the main water line and prior to the system to regualte
pressure. If applicable, a check valve on the main supply before the system or a check valve on the outlet side of the the
system (water heater will require expansion tank) to prevent backflow and excessive head pressure may be required.
Location of system on the lowest or highest floor or where home is located at the bottom or top of a hill may create head
pressure or pressure variances.
A flexible capability will assist with the installation where the rough plumbing and finish measurements are slightly off.
WARNING:
All threaded connections:
do not use pipe joint compound or pipe dope.
Use Teflon tape only on all external pipe threads.
Hand tighten only. do not overtighten.
Make sure any o-rings or gaskets are in place.
valve - big picture of flow direction in & out
Valve
Back View - Outlet Side
Outlet
outgoing
filtered water
to the home
Inlet
incoming
raw water
from supply
drain line