CAUTION:

 

Allow for a gentle curve when using flexible connections to avoid a rigid connection. 

 

 

Support inlet and outlet plumbing in some manner (use pipe hangers) to keep the weight off of the  

 

 

valve fittings.

WARNING:

  

If making any soldered copper connections:

 

 

no heat, Do all sweat soldering before connecting pipes to valve to avoid damage to internal parts.

WARNING:

 

Any pressure on the system exceeding, surging or spiking above 75 psi and any negative pressure  

 

 

due to vacuum break voids the warranty.**

**

An operating pressure reducing valve (PRV) may be required on the main water line and prior to the system to regualte 

pressure. If applicable, a check valve on the main supply before the system or a check valve on the outlet side of the the 

system (water heater will require expansion tank) to prevent backflow and excessive head pressure may be required. 

Location of system on the lowest or highest floor or where home is located at the bottom or top of a hill may create head 

pressure or pressure variances. 

A flexible capability will assist with the installation where the rough plumbing and finish measurements are slightly off. 

WARNING:

  

All threaded connections: 

 

 

do not use pipe joint compound or pipe dope. 

 

 

Use Teflon tape only on all external pipe threads. 

 

 

Hand tighten only. do not overtighten. 

 

 

Make sure any o-rings or gaskets are in place.

valve - big picture of flow direction in & out 

Valve

Back View  - Outlet Side

Outlet 

outgoing 

filtered  water 

to the home

Inlet

incoming 

raw water 

from supply

drain line

Содержание CWL-1354-1.5

Страница 1: ...oming line size Model Numbers Whole Home and Light Commercial Water Filtration Conditioning Systems EWS 1354 1 5 Whole Home and Light Commercial Water Filtration Systems CWL 1354 1 5 Retain this Produ...

Страница 2: ...ss and outgoing valve closed Page 12 6 Allow system to start itself up and self clean the filtration media Page 13 7 Open valve on the outgoing line keep bypass closed and put system in service positi...

Страница 3: ...drain line installation in the Product and Installation Guide depth minimum 22 needed for proper installation Complete setup install and startup of these systems can be found in this Product and Insta...

Страница 4: ...Open Outlet Side of Bypass System Ready for Use Run Water throughout the Home Product Blow Out for illustration purposes 16 Warranty 17 Valve Parts Blow Out 18 Back Cover with EWS Contact Information...

Страница 5: ...d system to conform with all codes and ordinances Installation location Install system in a protected area Always connect the system to the main water supply pipe feeding the entire home before the wa...

Страница 6: ...install a non restrictive spring check valve in drain line within the first 2 of the drain port if drain line exceeds 20 in total length or drain line flows over 5 above the height of the drain port...

Страница 7: ...arts or boxes lying around Once filled with water correcting something can be a problem 5 Locate water line or pipe to be cut and make sure of direction of water flow CAUTION Do not cross connect or p...

Страница 8: ...ve on the main supply before the system or a check valve on the outlet side of the the system water heater will require expansion tank to prevent backflow and excessive head pressure may be required L...

Страница 9: ...less to make the final connections with the valve Configuration may vary recommendation Let s build the bypass against the wall use less space and make the correct connections 1 Build your bypass 2 Se...

Страница 10: ...in drain line within the first 2 of the drain port to prevent possible back flow minimum 1 air gap normal flow 7 Plumb rigid tubing only PVC recommended if code applicable directly to the 3 4 FNPT br...

Страница 11: ...y ground system to conform with all codes and ordinances 4 _ SRV 00 00PM REGEN IN 06 DAYS Set Up Button Adjusts Clock Up Adjusts Other Settings as needed Set Down Button Adjusts Clock Down Adjusts Oth...

Страница 12: ...osed inlet to valve outlet from valve in raw water supply out filtered to home bypass closed valve closed clear the plumbing lines and connections 11 1 Keep the inlet and outlet closed to and from the...

Страница 13: ...et next backwash in 6 days and correct time of day CYCLE 2 00 04 59 BRINE SLOW RINSE CYCLE 3 00 09 59 RAPID RINSE 4 _ SRV 00 00PM REGEN IN 06 DAYS Start Up TO Flush the system 13 Press the Extra Cycle...

Страница 14: ...the drain water remains grey Press the Extra Cycle Button and repeat the flushing sequence until the water from the drain line runs clear minimum 1 air gap look for clear water coming from the drain...

Страница 15: ...oudy Water If water appears cloudy allow to run for several more minutes until all air is expelled or until clear NOTE Pre existing conditions older homes heavy sediment If home is a year or more old...

Страница 16: ...oard Top 1 3 of tank is empty for proper backwash and lift of filtration media for the automatic self cleaning of the system Tank Wrap eco cover for tank with contact infomation and information impor...

Страница 17: ...bsites and in all service guides supplied with all product Limited Warranty EWS Inc a Nevada corporation hereby warrants all products to the original consumer purchaser to be free from defects in mate...

Страница 18: ...18...

Страница 19: ...19 left blank if any adjustments have been made to backwash frequency up to 10 days for a water conservation setting or any other settings this is a good page to write those notes...

Страница 20: ...bing Wholesale Supply Locations and their building plumbing HVAC and service contractors and Authorized Online Distributors EWS is a Proud Contributor and Sponsor of Organizations Dedicated to Improvi...

Отзывы: