![Environmental Water Systems CWL-1354-1.5 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/environmental-water-systems/cwl-1354-1-5/cwl-1354-1-5_product-and-installation-manual_2416120003.webp)
3
installation dimensions
- Model #’s EWS-SPECTRUM, CWL-SPECTRUM, EWS-1035, CWL-1035
For Illustration Purposes Only:
Tank, valve and all contents (as pictured below) for these systems are delivered fully assembled.
Plumber installed bypass is required.
overall
height
63”
height
to center
incomng
56-3/4”
height
to center
outgoing
58”
height
to center
drain
57-5/8”
tank
height
54”
tank width 13”
Flexible Connections Required:
Stainless steel corrugated water connectors, PEX or PVC Sch 40 have a flexible capability that may assist with issues where the
rough and finish measurements are slightly off or where pressure surges/spikes or back pressure occur. This flexible connection may
prevent tank and valve issues where rigid or hard pipe create problems over time. This is a requirement of the tank manufacturer
and is stated on the label affixed to every tank. Perform all plumbing according to state or local codes.
Drain Line Air Gap Required and Spring Check Highly Recommended:
Please see information for proper drain line installation in the Product and Installation Guide
depth: minimum 22” needed for proper installation
Complete setup, install and startup of these systems can be found in this Product and Installation Guide
*Not Supplied:
Due to variations in installations, length and sizing needed for pipe connections to and from the system (see flexible requirement) and drain line are not supplied
For Illustration Purposes only:
Corrugated flexible stainless not supplied
Valve
(front view)
Not pictured:
Electric Transformer,
Bypass Valve and
Adaptors to the rear
of the Valve.
All measurements are
approximates
and system heights
may have
variances up to 1”.
Pictured:
eWs-1354-1.5
CWl-1354-1.5
weight dry: approx 155 lbs
weight wet: approx 370 lbs
CAuTIoN: If installing other equipment in addition to this system - Contact customer service for proper order of installation
Plumber installed
bypass is required
1.5” brass close or shoulder nipples,
1.5” corrugated flexible stainless,
all incoming/outgoing piping and
3 ball valves are not supplied
For Illustration Purposes Only:
This is an example of 3 valve bypass
using corrugated flexible stainless
to make the final connections
with the valve.
Configuration may vary
Содержание CWL-1354-1.5