Initial Installation
QUALIFIED INSTALLERS ONLY
h
oRizontaL
t
eRmination
- R
eaR
v
ent
:
12” (31 cm) Max. vent length
Max. 1 x 45
˚
Elbow
Figure 32. Corner Rear Vent
Approved through wall thimble
Figure 33. Flat to Wall Rear Vent
6” (15 cm) Min. vent length
18” (46 cm) Max. vent length
Approved through wall thimble
Note:
For every 12” (305mm)
of horizontal venting travel there
should be at least 1/4: (6.4mm) of
vertical travel.
DATE: 8/8/2014
BY
SHERWOOD INDUSTRIES LTD.
INTERNAL ASSEMBLY MANUAL
STATION:
THIS DRAWING IS THE PROPERTY OF SHERWOOD INDUSTRIES LTD. AND MAY NOT BE COPIED, REPRODUCED, OR OTHERWISE DISCLOSED WITHOUT THE PRIOR APPROVAL OF SHERWOOD INDUSTRIES LTD.
STEP:
1 of 1
SHEET:
PART NUMBER:
UPDATED: ----/--/--
BY --
STATION 1
STATION 3
STATION 4
STATION 2
The Q2LI / Q2LID can be installed as a natural gas Appliance in rear vent applications with no vertical
rise within the parameters as shown in Figures 32 and 33. If any vertical rise is required a top vent
configuration should be used.
* For optimal performance when rear venting (Propane or Natural Gas) use of a 14” snorkel termination
is strongly recommended: M&G DuraVent #46DVA-SNK14, ICC ExcelDirect #ST14,
Selkirk Direct Temp#4DT-ST14
Approved horizontal termination*
[See boxed statement]
Approved horizontal termination*
[See boxed statement]