16
f
ueL
c
onveRsion
:
Maintenance And Service
TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY
Please read and understand these instructions before installing.
Warning: This conversion kit shall be installed by a qualified service agency in accordance
with the manufacturer’s instructions and all applicable codes and requirements of the
authority having jurisdiction. If the information in these instructions is not followed
exactly, a fire, explosion or production of carbon monoxide may result causing property
damage, personal injury or loss of life. The qualified service agency is responsible for
the proper installation of this kit. The installation is not proper or complete until the
operation of the converted appliance is checked as specified in the manufacturer’s
instructions supplied with the kit.
Kit Parts List:
1 - Orifice (NG - #46 DMS or LP - 1.2 mm)
1 - Servo Regulator with diaphragm
1 - Installation instruction sheet
1 - Conversion label
Carefully inspect all parts supplied with this conversion kit. If any parts have been damaged or are
missing, contact your dealer, distributor or courier company to have them replaced before starting this
installation.
b
uRneR
R
emovaL
:
The burner may need to be removed for a few reasons, including cleaning under the burner, converting
the unit to a different gas type, or to replace the burner altogether.
Proceed only when the unit has
completely cooled down.
Figure 19. Removing Burner.
1. Remove the glass door as shown in the
m
aIntenance
anD
s
erVIce
- g
lass
D
oor
r
emoVal
.
2. Remove the log set and fire grate as
shown in S
econDary
I
nstallatIon
- f
Ire
g
rate
anD
l
og
s
et
I
nstallaIon
3. Push the air shutter in until it stops
4. Lift the burner straight up then out.
To re-install the burner follow steps 1-4 in
reverse. When placing the burner back in
the unit be sure to adjust the air shutter
back to the correct setting.