Installation
H
oRizontaL
e
XHauSt
t
HRougH
W
aLL
i
nStaLLation
:
Vent installation: install vent at clearances specified by the vent manufacturer.
A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces,
or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired,
the installation shall conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning Appliances and
Equipment. Only use venting of L or PL type with an inside diameter of 3 or 4 inches (7.6 or 10.1 cm).
1. Choose a location for your stove that meets
the requirements stated in this manual and
allows installation with the least amount of
interference to house framing, plumbing,
wiring, etc.
2. Install a non-combustible hearth pad
(where necessary).
3. Place the appliance 15” (37.5 cm) away
from the wall. If the stove is to be set on
a hearth pad, set the unit on it, and adjust
the leveling legs.
4. Locate the center of the exhaust pipe on
the stove. Extend that line to the wall.
Once you have located the center point on
the wall, refer to pellet vent manufacturer
installation instructions for correct hole
size and clearance to combustibles.
5. Install the wall thimble as per the
instructions written on the thimble.
Figure 25: Straight through wall Installation.
Non-combustible
floor protection.
Existing floor
(combustible)
6"
(15 cm)
4"
(10 cm)
Wall
thimble
45°
elbow
12"
(30.5 cm)
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
MODE
Exhaust Tube
3" (75mm) or 4" (100mm) "PL" or "L" vent
Wall Thimble
45° Elbow with screen or
Termination Cap
High Temperature RTV
Silicone Required
Fresh Air Intake Tube
ROO
M A
IR
FAN
ON
/OFF
ON/O
FF
FEE
D R
ATE
TRIM
COM
BUS
TIO
N
BLO
WER
TRIM
HEA
T LE
VEL
AUT
O/O
FF
HIG
H/LO
W
MAN
UAL
AUG
ER
MOD
E
Figure 26: Venting to use with straight through wall Installation.
Maintain an effective vapour
barrier in accordance with
local building codes.
6. Install a length of 3” (75
mm) or 4” (100 mm) vent
pipe into the wall thimble.
The pipe should install easily
into the thimble.
7. Connect the exhaust vent
pipe to the exhaust pipe on
the stove. Seal the connection
with
high
temperature
silicone.
8. Push the stove straight back,
leaving a minimum of 4” (10
cm) clearance from the back
of the stove to the wall. Seal
the vent pipe to the thimble
with
high
temperature
silicone.
20