background image

FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, 

PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

•  All ENVIRO gas-fired appliances must be installed 

in accordance with their instructions. Carefully read all 

the instructions in this manual first. Consult the building 

authority having jurisdiction to determine the need for 

a permit prior to commencing the installation.
•   

NOTE:

  Failure  to  follow  these  instructions  could 

cause  a  malfunction  of  the  fireplace,  which  could 

result in death, serious bodily injury, and/or property 

damage.
•  Failure to follow these instructions may also void 

your fire insurance and/or warranty.

GENERAL

•  Installation  and  repair  should  be  done  by  a 

qualified  service  person.  The  appliance  should 

be  inspected  before  the  first  use  and,  annually 

thereafter by a qualified service person. More frequent 

cleaning  may  be  required  due  to  excessive  lint  from 

carpeting, bedding material, etc.  It is imperative the 

control  compartments,  burners  and  circulating  air 

passageways of the appliance be kept clean.
•  Due  to  high  temperatures,  the  appliance  should 

be  located  out  of  high  traffic  areas  and  away  from 

furniture and draperies.

Children  and  adults  should  be  alerted  to  the 

hazards  of  high  surface  temperatures  and 

should  stay  away  to  avoid  burns  or  clothing 

ignition.
Young  children  should  be  carefully  supervised 

when  they  are  in  the  same  room  as  the 

appliance.

FOR YOUR SAFETY

•  Installation and service must be performed by a 

qualified installer, service agency or gas supplier.
•  This installation must conform to local codes or, in 

the absence of local codes, to the current CAN/CGA-

B149 installation code (Canada) or National Fuel Gas 

Code ANSI Z223.1.2 (USA).
•  To  prevent  injury,  do  not  allow  anyone  who  is 

unfamiliar with the stove to operate it.

 

To  prevent  injury,  if  the  pilot  or  pilot  and 

burners have gone out on their own, open the 

glass door and wait 5 minutes to air out before 

attempting to re-light the stove.

•  Always keep the area around this appliance clear 

of combustible material, gasoline and other flammable 

liquids and vapours.
•  This  appliance  should  not  be  used  as  a  drying 

rack for clothing or for hanging Christmas stockings/

decorations.
•  Due to the paint curing on the stove, a faint odor 

and  slight  smoking  will  likely  be  noticed  when  the 

stove is first used.  Open a window until the smoking 

stops.
Always connect this gas stove to a vent system and 

vent  to  the  outside  of  the  building  envelope.  Never 

vent to another room or inside the building. Make sure 

the specified vent pipe is used; properly sized and of 

adequate  height  to  provide  sufficient  draft.    Inspect 

the venting system annually for blockage and signs of 

deterioration.

WARNING: 

Failure to position the parts in accordance 

with the diagrams in this booklet, or failure to use only 

parts  specifically  approved  with  this  appliance  may 

result in property damage or personal injury.

WARNING: 

Do  not  operate  with  the  glass  front 

removed,  cracked  or  broken.    Replacement  of  the 

glass must be done by a licensed or qualified service 

person.
•  Never  use  solid  fuels  such  as  wood,  paper, 

cardboard, coal, or any flammable liquids, etc., in this 

appliance.
•  Do not use this heater if any part has been under 

water. Immediately call a qualified service technician 

to inspect the heater and to replace any part of the 

control or gas control systems that have been under 

water.
•  Do not abuse the glass by striking it or slamming 

the door shut.

Safety Precautions

2

Содержание EG28 BV

Страница 1: ...tly a fire or explosion may result causing property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier FOR YO...

Страница 2: ...lation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burners...

Страница 3: ...7 Installation Into An Existing Chimney 7 Straight Vertical Installation 8 Electrical Requirements 9 Replacing The Blower 10 Adjusting The Venturies 10 Fuel Conversion 11 Gas Line Connection and Testi...

Страница 4: ...LTITUDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO EG28 BV Fireplace Has been certified for use with either natural or propane gases See rating label Is not for...

Страница 5: ...flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room that is centrally located in the house This will optimize he...

Страница 6: ...m designed to protect against improper venting of combustion products This safety switch is located on the rear of the appliance close to the drafthood relief opening If the switch trips more than onc...

Страница 7: ...This basic venting configuration shown are rough guidelines only Follow national and local codes for other installation options Measure the height of the chimney beforehand and purchase the appropriat...

Страница 8: ...accounts for 5 feet 1 5 m of the horizontal run The venting should never slope down a minimum 1 4 inch 0 6 cm rise is needed for every 2 feet 61 cm of horizontal is recommended If practical it is best...

Страница 9: ...ged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug CAUTION Label all wires prior to disconnection when servicing controls Wiring errors ca...

Страница 10: ...tips are not getting enough air Open the venturi until the flames clean up If the venturi is opened or closed all the way and the correct flames cannot be attained turn off the gas and contact the de...

Страница 11: ...ew pilot injector supplied with the conversion kit Screw the new injector inside the pilot assembly and re install the hood by placing the hood on the assembly line up the keyway and snap into place S...

Страница 12: ...lated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45...

Страница 13: ...ent embers 1 The embers can be place before or after the logs are placed A bag of ceramic fiber embers and rock wool embers is provided gently remove the ember material from the plastic bag Spread a l...

Страница 14: ...the fan on for the first 4 hours This will cure the paint logs gasket material and the other products used in the manufacturing process It is advisable to open a window or door as the unit will start...

Страница 15: ...utes to clear out any gas Close door If you smell gas including near the floor STOP Follow B in the above safety information Leak test all gas joints with soapy water NEVER USE AN OPEN FLAME FOR LEAK...

Страница 16: ...n To clean the door use a mild glass cleaner and a soft cloth or a glass cleaner available from your Enviro dealer Abrasive cleaners will damage the glass TO REPLACE DOOR The glass in this appliance i...

Страница 17: ...pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on...

Страница 18: ...024 6 Burner Switch EC 025 Fan Access Cover Gasket EC 029 7 Miniature Light Bulb 115V EC 031 7 Light Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Burner Wiring Harness EC 037A Body Wiri...

Страница 19: ...P To NG Conversion Kit EG28 201 NG To LP Conversion Kit EG28 203 27 Glass Set with Gasket EG28 205 Thermocouple Pilot Nut EG28 210 28 Fan Mounting Bracket EG28 304 29 Venturi EG31 099 Control Panel De...

Страница 20: ...Parts Diagram Chassis 20 EG 28 Body Chassis July 2004...

Страница 21: ...21 Parts Diagram Gas Tray Door EG 28 Gas Tray and Door Assemblies July 2004...

Страница 22: ...nty on all the Electrical Components and Gas Components against manufacturing defects Paint is covered against flaking This offer includes parts and labor for 1 year and for parts only thereafter Your...

Страница 23: ...____________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy N...

Отзывы: