Initial Installation

F

UEL

 C

ONVERSION

:

WARNING:  This  conversion  kit  shall  be  installed  by  a  qualified  service  technician 

in  accordance  with  the  manufacturer’s  instructions  and  all  applicable  codes  and 

requirements of the authority having jurisdiction.  If the information in these instructions 

is not followed exactly, a fire, explosion or CO poisoning may result.  The qualified service 

agency is responsible for the proper installation of this kit.  The installation is not proper 

or complete until the operation of the converted appliance is checked as specified in the 

owner’s conversion kit.

Please read and follow these instructions. Also please read the instruction guidelines provided by S.I.T on how to 

remove and install the HI-LOW regulator.
STEP 1.   Carefully inspect all parts supplied with this conversion kit. 
STEP 2.   Shut the gas off and disconnect the main gas line from the unit.
STEP 3.   Open the door by unscrewing the 1⁄2” bolt on the right hand side of the stove.  Lift door off the hinges 

mounted on the left-hand side.  

STEP 4.   Carefully remove the log set and ember material if they are installed.
STEP 5.  Remove the two (2) T-20 screws on the burner tray located between the front and rear burners.
STEP 6.  Change the regulator on the top of the gas valve. (Follow the instructions provided by S.I.T)
STEP 7.  To change the pilot, pull the pilot hood straight up to access the pilot injector, using a 

5

/

32

” Allen key, 

remove the pilot injector.

STEP 8.  Install new pilot injector supplied with the conversion kit. Screw the new injector inside the pilot assembly 

and re-install the hood by placing the hood on the assembly, line up the keyway and snap into place

STEP 9.  Remove the two (2) main burner orifices using a 1⁄2” deep socket.
STEP 10. Install the two (2) new orifices supplied making sure that the orifices are in the correct location. Be sure 

to put a bead of pipe thread sealant or approved Teflon tape on the orifices before installing them into 

the burner assembly.

STEP 11. Re-install burner tray, log set and door. Also refer to “Installing Log Set and Embers.”
STEP 12. Reconnect the gas line to the unit.  Do a leak check using soap and water solution or an approved method 

on the gas supply  and the pilot tubing. 

STEP 13. Re-light the appliance to ensure proper operation and proper flame appearance. Be sure to adjust the 

venturi setting to achieve an efficient flame in the fireplace.

STEP 14. MAKE SURE that the sticker provided by S.I.T is installed to signify that this valve has been converted to 

a different type of fuel. Also make sure that the rating plate has a conversion label to show that this unit 

has been converted to a different fuel type.

A VISUAL CHECK OF THE REGULATOR KNOB IS NECESSARY TO DETERMINE WHETHER OR NOT THE REGULATOR 

IS THE CORRECT PART.  A 50% TURN DOWN REGULATOR WILL HAVE ONLY ONE CORNER ON THE KNOB.

1 - 50% turn down HI-LOW Regulator
3 - T-20 Torx screws
1 - T-20 tamper proof Torx screwdriver bit
1 - pilot injector
2 - Main orifice
Labels to show conversion.

Natural Gas

Propane

Pilot Orifice

.62 mm

.35 mm

Burner Orifice

#43 DMS

#53 DMS

Venturi Setting

1

/

16

” min.

1⁄4” Min

Table 3: Orifice Information.

Содержание EG28 BV

Страница 1: ...tly a fire or explosion may result causing property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier FOR YO...

Страница 2: ...lation code Canada or National Fuel Gas Code ANSI Z223 1 2 USA To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burners...

Страница 3: ...7 Installation Into An Existing Chimney 7 Straight Vertical Installation 8 Electrical Requirements 9 Replacing The Blower 10 Adjusting The Venturies 10 Fuel Conversion 11 Gas Line Connection and Testi...

Страница 4: ...LTITUDES CSA P 4 1 02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO EG28 BV Fireplace Has been certified for use with either natural or propane gases See rating label Is not for...

Страница 5: ...flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room that is centrally located in the house This will optimize he...

Страница 6: ...m designed to protect against improper venting of combustion products This safety switch is located on the rear of the appliance close to the drafthood relief opening If the switch trips more than onc...

Страница 7: ...This basic venting configuration shown are rough guidelines only Follow national and local codes for other installation options Measure the height of the chimney beforehand and purchase the appropriat...

Страница 8: ...accounts for 5 feet 1 5 m of the horizontal run The venting should never slope down a minimum 1 4 inch 0 6 cm rise is needed for every 2 feet 61 cm of horizontal is recommended If practical it is best...

Страница 9: ...ged directly into a properly grounded three prong outlet DO NOT cut or remove the grounding prong from this plug CAUTION Label all wires prior to disconnection when servicing controls Wiring errors ca...

Страница 10: ...tips are not getting enough air Open the venturi until the flames clean up If the venturi is opened or closed all the way and the correct flames cannot be attained turn off the gas and contact the de...

Страница 11: ...ew pilot injector supplied with the conversion kit Screw the new injector inside the pilot assembly and re install the hood by placing the hood on the assembly line up the keyway and snap into place S...

Страница 12: ...lated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45...

Страница 13: ...ent embers 1 The embers can be place before or after the logs are placed A bag of ceramic fiber embers and rock wool embers is provided gently remove the ember material from the plastic bag Spread a l...

Страница 14: ...the fan on for the first 4 hours This will cure the paint logs gasket material and the other products used in the manufacturing process It is advisable to open a window or door as the unit will start...

Страница 15: ...utes to clear out any gas Close door If you smell gas including near the floor STOP Follow B in the above safety information Leak test all gas joints with soapy water NEVER USE AN OPEN FLAME FOR LEAK...

Страница 16: ...n To clean the door use a mild glass cleaner and a soft cloth or a glass cleaner available from your Enviro dealer Abrasive cleaners will damage the glass TO REPLACE DOOR The glass in this appliance i...

Страница 17: ...pilot dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pressure Check for flame impingement on...

Страница 18: ...024 6 Burner Switch EC 025 Fan Access Cover Gasket EC 029 7 Miniature Light Bulb 115V EC 031 7 Light Bulb Holder EC 032 Wiring Harness Complete 2 pieces EC 037 Burner Wiring Harness EC 037A Body Wiri...

Страница 19: ...P To NG Conversion Kit EG28 201 NG To LP Conversion Kit EG28 203 27 Glass Set with Gasket EG28 205 Thermocouple Pilot Nut EG28 210 28 Fan Mounting Bracket EG28 304 29 Venturi EG31 099 Control Panel De...

Страница 20: ...Parts Diagram Chassis 20 EG 28 Body Chassis July 2004...

Страница 21: ...21 Parts Diagram Gas Tray Door EG 28 Gas Tray and Door Assemblies July 2004...

Страница 22: ...nty on all the Electrical Components and Gas Components against manufacturing defects Paint is covered against flaking This offer includes parts and labor for 1 year and for parts only thereafter Your...

Страница 23: ...____________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy N...

Отзывы: