 OPERATING INSTRUCTIONS

 

 

FOR YOUR SAFETY READ BEFORE OPERATING 

WARNING:

 IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION  

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 

 
A)  This appliance is equipped with a pilot, which must be lit by 

hand by following these instructions exactly. 

B)  BEFORE LIGHTING smell all around the appliance area 

for gas, and next to the floor because some gas is heavier 
than air and will settle on the floor. 

WHAT TO DO IF YOU SMELL GAS

:   

• 

Do not try to light any appliance. 

• 

Do not touch any electrical switch; do not use any 
phone in your building. 

• 

Immediately call your gas supplier from a neighbor’s 
phone.  Follow the gas supplier’s instructions. 

 

• 

If you cannot reach your gas supplier, call the fire 
department. 

C)  Use only your hand to  push in or turn the gas control 

knob.  Never use tools.  If the knob will not push in or turn 
by hand, do not try to repair it .  Call a qualified service 
technician.  Force or attempted repair may result in a fire 
or explosion. 

D)  Do not use this appliance if any part has been under 

water.  Immediately call a qualified service technician to 
inspect the appliance and to replace any part of the 
control system and any gas control which has been under 
water 

 

LIGHTING INSTRUCTIONS

 
1.  STOP!  Read the safety information above.  
2.  Turn off all electrical power to the 

appliance. 

3.  Turn the gas control knob clockwise 

to 

the “off’ position. 

 

4. Open 

door. 

 Wait five (5) minutes to clear out any gas

.  

Close door.  If you smell gas including near the floor, 

STOP!

 Follow  “B” in the above safety information. 

If you don’t smell gas go to next step. 

5.  Find the pilot located to the right between the front  and 

rear burner. 

6.  Turn gas control knob counter-

clockwise to “PILOT”. 

7.  Push the gas control knob in fully and hold.  Immediately 

light the pilot by pushing the piezo spark igniter.  Keep 
knob depressed for about 30 seconds after pilot is lit.  
Release knob.  If pilot goes out, repeat steps 4 through 6.  

WARNING 

 The gas valve has a lockout device, which 

will not allow the pilot burner to be re-lit until the 
thermocouple, has cooled. 

If the knob does not pop up when released, stop and 

immediately call your service technician or gas supplier. 

 

NOTE:

  Check to be sure the pilot flame engulfs the 

thermocouple

 and that the burners light completely. 

 

If the pilot will not 
stay lit after 
several tries, turn 
the gas control 
knob to “OFF" 
and call you 
service 
technician or gas 
supplier. 

 
 
8.  Turn gas control knob counter-clockwise 

to the “ON” position.   
Flip burner switch to “ON” then turn “HI / LO” knob to the 
desired setting. 

HI \ LO knob 

Control knob

 
9. Turn 

on all electrical power to the unit

 

 

 

TO TURN OFF GAS TO 

APPLIANCE

1.  Turn the gas control  knob clockwise 

to 

“OFF”    DO NOT FORCE  

2.  Turn off all electrical power to the appliance if service is to 

be performed. 

3.  Flip burner switch to off. 

 

15

Содержание EG 28

Страница 1: ...tely call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING If the information in this manual is n...

Страница 2: ...stallation must conform to local codes or in the absence of local codes with the current CAN 1 B 149 installation code in Canada or the current National Fuel Gas Code ANSI Z223 1 in the USA To prevent...

Страница 3: ...tural or propane gases see control panel and rating label are not for use with solid fuels must not be connected to a chimney flue serving a separate solid fuel burning appliance are approved for bedr...

Страница 4: ...re the flue system of the stove can be properly installed without damaging the integrity of the building e g cutting a wall or ceiling joist The stove can be installed on any standard flooring materia...

Страница 5: ...to a mechanical air supply inlet 6 feet 1 8m minimum L Clearance above paved side walk or paved driveway located on public property 7 feet 2 1m minimum M Clearance under verandah porch deck or balcony...

Страница 6: ...HE OUTSIDE VENT TERMINATION BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT TERMINATION CAN BE ACCOMMODATED FOLLOW THE VENT LENGTH DIAGRAM PRECISELY...

Страница 7: ...shown in FIG 10 NOTE 1 Twist lock procedure four indentations located on the female end of the pipes and fittings are designed to slide straight onto the male ends of adjacent pipes and fittings by o...

Страница 8: ...excessive heat from possibly melting the vinyl siding material Note that the horizontal vent termination bolts onto the flat portion of the vinyl siding standoff shaded area in FIG 12 so that an air...

Страница 9: ...pipe and elbows may be utilized in the attic as well as above the roofline The galvanized finish is desirable above the roofline due to the higher corrosion resistance STEP 6 Once the pipe sections h...

Страница 10: ...quired at the second floor and any subsequent floors FIG 19 The opening should be framed to 10 inch x 10 inch inside dimensions in the same manner as shown in FIG 16 2 Any occupied areas above the fir...

Страница 11: ...ide on a location for the unit that will meet any or all local code requirements Refer to sections in this manual Deciding Were To Locate Your Stove and Planning Your Installation Set the appliance in...

Страница 12: ...liner over collar secure the flex liner with 3 sheet metal screws evenly spaced Align all straight sections of pipe slipping all joints together and installing 3 sheet metal screws evenly spaced A sm...

Страница 13: ...minimum 4 flex liner to the top of the CLASS A chimney Placing a bead of high temperature silicone to the Simpson Cap adapter and securely attach the flex liner to the adapter Secure the cap adapter t...

Страница 14: ...EVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED INSTALLING THE LOGSET INSTALLING THE LOGSET Carefully remove log from box Check to ensure there is no damage It is very important to install this log...

Страница 15: ...f all electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the fl...

Страница 16: ...about the first two weeks of use After that depending upon the amount of use cleaning should be required no more than two or three times per season To clean the door use a mild glass cleaner and a sof...

Страница 17: ...thermocouple Air in gas line Pilot flame dies while knob is depressed Bleed line Check gas line pressure Contact dealer Burners will not remain lit Problem with thermopile circuit Check gas line pres...

Страница 18: ...ition of the National Fuel Gas Code ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap M...

Страница 19: ...d securely to the floor WARNING ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a pro...

Страница 20: ...ower does not require lubrication 20 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burners Li...

Страница 21: ...ided by S I T STEP 5 To change the pilot orifice First remove the two 2 T 20 Torx screws that hold the pilot assembly to the burner tray Lift the pilot assembly from the burner tray Using a 10mm wrenc...

Страница 22: ...rts only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under...

Страница 23: ...143 BURNER COMPLETE W NOVA SIT VALVE NG EC 024 SS FLEX CONNECTOR WITH 3 8 ELBOW 18 LONG EG28 145 BURNER COMPLETE W NOVA SIT VALVE LP EC 025 BURNER SWITCH FOR NOVA TRAY EG28 150 ASH SILL EC 029 FAN ACC...

Страница 24: ...ET FS CABINET SIDE PANEL EG28 123 BV TOP BAFFLE EG28 132 DV TOP BAFFLE EG28 131 FS CABINET SIDE PANEL EG28 123 BV 4 CRIMPED FLUE PIPE EG28 169 DV 4 FLARED FLUE PIPE EG28 170 120 F 49 C CERAMIC FAN TEM...

Страница 25: ...LASS A B EG28 101 BURNER CONTROL ASSEMBLY COMPLETE EG28 143 NG EG28 145 LPG FULLY ASSEMBLED PILOT EC 015 NG 016 LP THERMOPILE EC 012 THERMOCOUPLE EC 009 PILOT ORIFICE EC 019 NG 020 LP SPARK ELECTRODE...

Страница 26: ..._______________________ Phone ___________________________________ Name of Installer ___________________________________________ Address _________________________________________ __ ___________________...

Отзывы: