Fuel Conversion
14
Figure 12: Removing valve
screw.
Figure 13: Flip valve
screw.
Figure 14: O-ring on valve screw.
Figure 15. Ignitor assembly
glass burner.
d) Insert a
5
/
32
” or 4 mm Allen wrench into the hexagonal key-way of the screw (see Figure
12), rotate it counter-clockwise until it is free and extract it.
e) Flip the screw (refer to Figure 13).
f) Using the Allen wrench as shown in Figure 12, rotate the screw clockwise.
WARNING!
Do not
over tighten the screw.
g) Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red
o-ring visible (refer to Figure 14). If the conversion is from LPG to NG, the red o-ring of the
screw must not be visible.
h) Re-attach the black protection cap that was removed in step “c)”. Refer to Figure 11.
i) Reinstall the knob extensions. They are keyed into the notch on the knob.
j) Reinstall the Valve Cover plate.
8. Reinstall the burner, porcelain panels, bowl, glass
material, and glass door. Also refer to
I
nstallatIon
-
F
IreBox
l
Iner
& B
urner
t
ray
r
emoVal
/I
nstallatIon
in your Owner’s Manual. When re-installing
the burner, ensure that the burner to pilot hood
relationship is similar to what is shown in Figure 15.
9. Reconnect the main gas line if it was disconnected
and open the shut-off valve at the gas line to the
unit.
10. Use a small brush to apply a warm soapy water
solution to all gas connections (use half dish soap
and half warm water). If a gas leak is present,
bubbling will occur. Gas leaks can be repaired by
using an approved pipe thread sealant or approved
Teflon tape. NEVER USE AN OPEN FLAME WHEN
TESTING FOR LEAKS.
11. Reconnect the electrical power to the unit.
12. Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition and
operation and proper flame appearance.
13. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the
unit has been converted to a different fuel type.