Initial Installation

QUALIFIED INSTALLERS ONLY

e

xhaust

 R

estRictoR

:

This fireplace has an internal exhaust restrictor rings. Usage of the restrictor rings is dependant  on 

the length of venting required and different installation requirements.  

instaLLation instRuctions:

1. Plan your installation and clearances 

to combustibles. The  E25 may be 

installed and vented into any solid 

fuel fireplace that has been installed 

in accordance with the National, 

Provincial/State and local building 

codes and has been constructed of 

non-combustible materials. Also refer 

C

learanCes

 

to

 C

ombustIbles

 

section.

2.  Remove door. See 

m

aIntenanCe

 

anD

 

s

erVICe

 - g

lass

 D

oor

 r

emoVal

.

2ft (0.6m)

Minimum

3ft (0.9m)

Minimum

Within

10ft (3m)

Roof ridge or 

any other portion 

of a building

Roof Clearances.

i

nstaLLing

 

the

 e25:

•  Remove the crate and packaging from the appliance and check to make sure there is no damage. 

Carefully check the glass door. Do not use the unit if it is damaged. In the event damage is found, 

please report it to your dealer as soon as possible. 

•  Carefully clean the fireplace and flue before installing the stove. Failure to do so may result in fumes 

or soot being blown into the room and may cause a fire leading to death or serious injury.

3. Remove packaged log set and all wrapping material from the stove. Remove wrapping material from 

the log set and check for any damage. If damage is observed, do not use unit and contact your local 

dealer.

2.5”

2”

2.25”

The restrictor rings are installed on the exhaust 

outlet The exhaust outlet is accessed from inside 

of the firebox. 

1. 

Remove door.

2. 

Undo the fasteners securing baffle.

3. 

 Use the wing nuts provided to secure 

the restrictor rings to the exhaust outlet.

Note: The E25 comes from the factory without 

any restrictor rings installed.

Use the restrictor rings  

at your discretion. 

Be sure a clean 

healthy burn is 

achieved after 15 

minutes of burning on 

High.

Содержание E25 Series

Страница 1: ...g property damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier Version Française www enviro com fr html C 4001609 W A R R A N T Y R E G I S T R A T I O N e n v i r o c o m w a r r a n t y E25 I P I N O VA G A S F I R E P L A C E I N S E R T ...

Страница 2: ...ier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier Massachusetts installations Warning This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts Other Massachusetts code requirements Flexible connector...

Страница 3: ... must be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 To prevent injury do not allow anyone who is unfamiliar with the stove to operate it To prevent injury if the pilot or pilot and burne...

Страница 4: ...ce And Service 17 Glass Door Removal 17 Cleaning the Painted Surfaces 18 Cleaning the Glass 18 Cleaning the Firebox 18 Replacing the Glass 18 Check Pilot and Burner Flames 18 Burner Removal 19 Fuel Conversion 20 Initial Installation 22 Surround Assembly 23 InstallingSurroundOn unit 23 Clearances to Combustibles 24 Minimum Fireplace Size 24 Venting 24 Exhaust Restrictor 26 Installing the E25 27 Hor...

Страница 5: ... with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a permanent wall thermostat for bedroom installations Consult the authority having local jurisdiction in your area IN USA see current ANSI Z223 1 for installation instructions Must be installed in accordance with local codes If none exi...

Страница 6: ...g label is located in the bottom of the unit Dimensions Install Depth The E25 has a minimum install depth of 13 5 343mm 619 24 4 357 14 1 730 28 8 493 19 4 693 27 3 248 9 8 273 10 8 527 20 8 526 20 7 471 18 5 343 13 5 990 60 39 00 652 78 25 70 1 162 ...

Страница 7: ...l electric power to the appliance 5 Do not attempt to light the pilot by hand 6 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above on this label If you don t smell gas go to the next step 7 Turn on all electric power to the appliance 8 Using the remote control set thermostat to desired setting or press...

Страница 8: ...ructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it Call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualifi...

Страница 9: ...indow be opened as the unit will start to smoke which can irritate some people After the unit has gone through the first burn turn the unit OFF including the pilot and let the unit get completely cold Then remove the glass and clean it with a good gas fireplace glass cleaner available at your local Enviro dealer See Maintenance And Service Glass Door Removal and Maintenance And Service Cleaning Th...

Страница 10: ... 1Hz Comfort modulating fan 120 V 60 Hz 2A Auxiliary 120 V 60 Hz 5A Transmitter The Proflame 2 Transmitter is a remote control with a blue backlit lcd display It uses a streamline design with a simple button layout and informative lcd readout The Transmitter is powered by three 3 AAA type batteries A Mode Key is provided to Index between the features and a Thermostat Key is used to turn on off or ...

Страница 11: ...kup four 4 AA type batteries for shorter periods of time The IFC accepts commands via radio frequency from the Transmitter to operate the appliance in accordance with the particular Proflame 2 system configuration The IFC has a red reset button at the front right corner that is used is to synchronize the Transmitter when using the for the first time or after the batteries have been replaced Integr...

Страница 12: ...ve fully from the unit When re inserting the tray back into the unit there is a cable management clip located at the back of the sliding tray ensure the cables are neatly placed under the clip To gain access to the ifc itself You can remove the 4 fasteners securing the top of the tray You must refasten the tray top to ensure the IFC does not overheat Accessing IFC when the tray is fully retracted ...

Страница 13: ...to complete Operating Instructions Turn off the Appliance Press the ON OFF Key on the Transmitter The Transmitter LCD display will only show the room temperature and Icon see Figure 9 A single beep from the IFC confirms reception of the command and both the pilot light if the unit is not set to continuous pilot and main burner will turn off Room Thermostat Transmitter Operation The Remote Control ...

Страница 14: ...me Level Flame Off Flame Level 1 Flame Level 5 Maximum Flame Level Fan Control The E25 comes with a convection fan that can be controlled with the Transmitter The fan speed can be adjusted thorugh six 6 speeds To control the fan press the MODE key to index to the fan control icon Figure 12 Use the UP DOWN arrow keys to turn on off or adjust the fan speed Figure 12 A single beep from the IFC will c...

Страница 15: ...ce burner when operating the remote system Operating Instructions WARNING Shock Hazard Can cause severe injury or death This device is powered by line voltage Do not try to repair this device In no way is the enclosure to be tampered with or opened Disconnect from line voltage before performing any maintenance CAUTION Property Damage Hazard Excessive heat can cause property damage The appliance ca...

Страница 16: ... allows the amount of air coming into the fireplace to be adjusted in order to accommodate different climates and venting arrangements Start the pilot and then the burner Make sure the pilot flame is burning normally and none of the burner ports are plugged Let the fireplace burn for roughly fifteen 15 minutes and then examine the flames The ideal flame will be blue at the base and light orange ab...

Страница 17: ...cally examined it is recommended the examination is done by a qualified person DoorSpringLatchLocations The glass door of the fireplace is retained at the top by two spring latches as shown above left Release the latches by placing the hooked end of the door tool in the hole on the door latch mechanism see above and pulling the latch forward then out to the side When the two 2 latches have been re...

Страница 18: ...r large amounts of soot a small amount on the logs is normal Replace the logs and embers as in the Secondary Installation Log Set and Ember Installation section If new more embers and rock wool are required contact your nearest ENVIRO dealer Replacing The Glass The glass in the fireplace is a high temperature ceramic If the glass is damaged in any way a factory replacement is required see Parts Li...

Страница 19: ... 2 3 1 Open door and remove logs from fireplace 2 Remove log stands and log grate Be careful not to scratch the paint when removing from fireplace 3 Unscrew the fasteners holding the log deflector tray 4 Insert hook end of door opening tool into slot in used for the log grate 5 Rotate rear of tray forward and remove log deflector tray 6 Unscrew the 4 fasteners holding down the burner and burner mo...

Страница 20: ...l 1 x Valve Body Conversion Label Stepper Motor For IPI ordered Separately 50 3753 LP to NG parts list 50 3982 38 bullet orifice 1 x Rating Plate Conversion Label 1 x Valve Body Conversion Label Stepper Motor For IPI ordered Separately 50 3870 1 Remove door 2 Carefully remove logs log stands and log grate from firebox Place aside for re installation 3 Insert door tool into slot used for log grate ...

Страница 21: ...l amount of silicone Pull rod and cap off of the valve Removing valve cap 5 Insert a 5 32 or 4 mm Allen wrench into the hexagonal key way of the screw rotate it counter clockwise until it is free and extract it 6 Check that the screw is clean and if necessary remove dirt 7 Flip the screw 8 Using the Allen wrench as shown in Figure 2 rotate the screw clockwise until a torque of 9 inch lbs WARNING D...

Страница 22: ...he inlet and manifold pressures are within the acceptable ranges as directed in section Intial Intallation Gas Line Connection and Testing If the E25 has been installed at an altitude higher than 2000ft 610m it is required to de rate the unit accordingly 6 In the USA The appliance may be installed at higher altitudes Please refer to your American Gas Association guidelines which state the sea leve...

Страница 23: ...plate DO NOT OVERTIGHTEN THE NUTS 5 Align the holes on the Safety screen with the holes on the surround sides 6 Thread the screw through the hole from the safety screen side to the surround side 7 Thread on the nut to the screw Do not fully tighten down the nut as this will hinder the movement of the screen Leave the nut loose approximately halfway down thread so the door can swing open Installing...

Страница 24: ...Fireplace Dimensions 28 711 mm 20 8 528 mm 19 5 495 mm 13 5 343 mm NOTE Space must be provided for gas line on left side of unit for servicing purposes Venting WARNING This appliance has been designed to draw room air for proper heat circulation from the sides and bottom of the unit and out the top front Blocking or modifying these openings in any way can create hazardous situations The vent lengt...

Страница 25: ...o installation Initial Installation QUALIFIED INSTALLERS ONLY The ENVIRO E25 may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National Provincial State and local building codes and has been constructed of non combustible materials Please reference the information in Table 7 and Figure 28 An approved chimney liner and rain cap must be used A t...

Страница 26: ...eck to make sure there is no damage Carefully check the glass door Do not use the unit if it is damaged In the event damage is found please report it to your dealer as soon as possible Carefully clean the fireplace and flue before installing the stove Failure to do so may result in fumes or soot being blown into the room and may cause a fire leading to death or serious injury 3 Remove packaged log...

Страница 27: ...of the exhaust vent terminal Slide the flex liner onto the vent terminal and secure with three 3 sheet metal screws evenly spaced 9 Place a bead of high temperature silicone on the Minimum Clearance Description 3 ft 0 9 m Clearance above the highest point where it passes through a roof surface refer to Figure 23 24 in 0 6 m Clearance above a roof ridge any other portion of a building or any other ...

Страница 28: ...Latch Unlatch Latch 12 Place a bead of high temperature silicone on the intake collar of the fireplace slide the Ø3 76mm flex intake liner over the collar secure the flex liner with three 3 sheet metal screws evenly spaced 13 Place the unit part way into the fireplace Connect the gas line to the NPT fitting on the right side of the unit using locally approved methods see Initial Installation Gas L...

Страница 29: ...ust venting do NOT exceed 90 degrees After the elbow stretch the venting to the desired vertical height Step 5 Attach the venting to the wall terminal using the supplied hose clamps Note the exhaust inlet is the inlet with the supplied reducer Step 3 Proceed to core or drill a hole at the predetermined height Use image on right as guide for core cutting Part D SCALE HEAT S MATERIAL UNLESS OTHERWIS...

Страница 30: ...low must be permanently attached inside the cavity of the fireplace in a visible location WARNING This fireplace has been converted for the use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced and the fireplace re approved by the authority having jurisdiction C 11168 Initial Installation QUALIFIED INSTALLERS ONLY The f...

Страница 31: ...stallation QUALIFIED INSTALLERS ONLY IFC Main Harness Transmitter TMFLSA 885 Gas Valve IPI Pilot Convection Fan Proflame 2 System Wiring Diagram Main On Off Power Cord To Battery Holder Flame Sensor Spark Electrode ...

Страница 32: ...pressure tap system Check pressures using a manometer When finished release pressure remove hose tighten set screw Gas Line Connection Prior to installation consult your local authorities codes or the CAN CGA B 149 1 or 2 installation code in Canada or in the USA gas installations follow either local codes or the current edition of the National Fuel Gas Code ANSI Z223 1 The appliance must be disco...

Страница 33: ... BTU hr 6 59 KW NEVER USE AN OPEN FLAME FOR LEAK TESTING Adjusting The Pilot Flame The pilot flow adjustment is set to maximum at the factory and should not need to be adjusted The pilot flame should envelope to 10 to 13mm of the Flame sensor see Figure 35 However should the need arise follow Steps 1 2 below 1 The adjustment screw can be reached through the front of the unit using a 10 inch long b...

Страница 34: ...top of pilot hood 2 Rotate the log grate A into slots on log deflector B 3 Locate notches on log stand A into holes on log deflector B A B A B 4 Locate notches on log stand A into holes on log deflector B A B Initial Installation Log Setup Guide ...

Страница 35: ... not to have heavy clumps of wool 8 Insert the A log onto the back pin aligning the front of the log to the flat part of the front log B B A 9 Insert the A log onto the back pin aligning the front of the log to the flat part of the front log B A B 10 Locate the notch on the small log and line the Notch up with the end tooth of the log grate 11 Locate the end of the log on the last tooth on the lef...

Страница 36: ...ed watch for ignition at ALL the burner ports If a long delay is noticed turn the appliance off and wait for it to cool down Then remove the glass and make sure none of the burner ports are blocked Maintenance Once a year the logs should be removed and checked for deterioration or large amounts of soot A small amount on the bottom side of the logs is normal Remove and replace the logs in the same ...

Страница 37: ... LED indicator will blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in intervals Additional Ignition Information 1 The Proflame2 IFC will try two 2 times for ignition 2 Each try for ignition will last approximately 60 seconds 3 The wait time between the two tries is approximatel...

Страница 38: ...s type settings on the valve and pilot burner assembly orifice Pilot will not remain lit Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC board Check pilot for full flame impingement around Flame Sensor If flame is too small check gas pressure adjust pilot rate screw check pilot head for damage Ensure the ground wire is properly attached to the pilot mou...

Страница 39: ...er temperature Flame lifting Leak in vent pipe Check for leaks in vent connections Improper vent configuration Check vent configuration with manual Terminal may be re circulating flue gases Check to see if terminal is on correctly May need to install high wind termination cap Contact dealer Blue Flames The heater has just been started Normal during start up flame will yellow as the fireplace heats...

Страница 40: ...40 Parts Diagram Components 9 8 7 6 4 19 11 10 12 13 16 14 3 2 15 1 5 17 18 20 21 22 23 ...

Страница 41: ...NG 50 2682 14 120 Ceramic Fan Temp Sensor All Models EC 001 15 E25 Fan Only 50 3901 16 Proflame 2 IFC 0 584 325 50 3312 17 E25 Surround Assembly 50 3845 18 E25 Safety screen only 50 3956 19 E25 Burner Assembly 50 3983 20 E25 complete door Assembly 50 3984 21 E25 Glass Gasket Only 50 2506 22 E25 Flue adapter 50 3987 23 S I T Piezo Ignitor EC 023 E25 Brick liner 50 3844 E25 Valve Tray Gasket 50 3985...

Страница 42: ...fety screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over firing due to incorrect setup or tampering Damage caused by incorrect installation To the Dealer Provide name address and telephone number of purchaser and date of purchase Provide date of pur...

Страница 43: ...___________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy DIRECT VENT NATURAL GAS NAT PROPANE LPG INLET GAS PRESSURE _________in WC MAIN BURNER ORIFICE __________ DMS PILOT ORIFICE _________OR________in diam INSTALLER S SIGNATURE ______________________________...

Отзывы: