15

I n s t a l l a t i o n ,   O p e r a t i o n ,   &   M a i n t e n a n c e   M a n u a l

MAC 10

®

 LEAC2

Fan Filter Unit

  

Limited Warranty

LIMITED WARRANTY: Unless otherwise expressly 

stated in ENVIRCO’s published specifications for the 

Goods,  ENVIRCO  warrants  that  Goods  are  free  from 

defects in material and workmanship, except for services 

which are warranted to be performed in a competent and 

diligent manner in accordance with any mutually agreed 

specifications. The foregoing warranty shall apply for 

eighteen  (18)  months  from  the  date  of  shipment  from 

ENVIRCO’s facility, except for services for which the 

warranty  shall  apply  for  ninety  (90)  days  from  the  date 

of performance (the “Warranty Period”). Provided Buyer 

informs ENVIRCO in writing of any breach of warranty 

prior to the expiration of the applicable Warranty Period, 

ENVIRCO shall, as its sole obligation and Buyer’s sole 

and exclusive remedy for any breach of this warranty, 

repair  or  replace/re-perform  the  Goods  which  gave  rise 

to the breach or, at ENVIRCO’ option, refund the amounts 

paid by Buyer for the Goods which gave rise to the breach. 

Any repair, replacement or re-performance by ENVIRCO 

hereunder shall not extend the applicable Warranty Period. 

The parties shall mutually agree on the specifications of 

any test to determine the presence of a defect. Unless 

otherwise agreed upon by ENVIRCO in writing, Buyer shall 

bear the costs of access, de-installation, re-installation 

and  transportation  of  Goods  to  ENVIRCO  and  back  to 

Buyer. These warranties and remedies are conditioned 

upon  (a)  the  proper  storage,  installation,  operation, 

and  maintenance  of  the  Goods  and  conformance  with 

the proper operation instruction manuals provided by 

ENVIRCO  or  its  suppliers  or  subcontractors,  (b)  Buyer 

keeping proper records of operation and maintenance 

during the applicable Warranty Period and providing 

ENVIRCO access to those records, and (c) modification 

or repair of the Goods only as authorized by ENVIRCO. 

ENVIRCO  does  not  warrant  the  Goods  or  any  repaired 

or replacement parts against normal wear and tear or 

damage caused by misuse, accident, or use against the 

instructions of ENVIRCO. Any modification or repair of any 

of  the  Goods  not  authorized  by  ENVIRCO  shall  render 

the warranty null and void. EXCEPT AS EXPRESSLY 

SET FORTH HEREIN, ENVIRCO MAKES NO OTHER 

WARRANTIES,  EXPRESS  OR  IMPLIED,  INCLUDING, 

BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES 

OF  MERCHANTABILITY,  NON-INFRINGEMENT  OR 

FITNESS FOR A PARTICULAR PURPOSE WHICH ARE 

HEREBY DISCLAIMED TO THE EXTENT PERMITTED 

BY APPLICABLE LAW. 

  

Testing 

Each MAC 10 LEAC2 filter unit is thoroughly tested at 

the factory before shipment. However, because of the 

“rigors” of shipping, ENVIRCO encourages its re-test after 

installation. 

ENVIRCO recommends that the customer contact an 

independent organization, with technicians trained and 

experienced in performance evaluation and maintenance 

of clean air equipment.

HEPA  filters  (Type  J)  are  tested  to  IEST-RP-00034. 

ULPA  filters  are  tested  to  (Type  F)  IEST-RP-00034. 

All filters are UL 900 recognized. Your filters may have 

special  requirements;  please  see  original  engineering 

specifications for your specific project.

All units that are airflow tested at ENVIRCO are tested 

using a Shortridge Airdata Multimeter 870 with a Velgrid 

head. The recommended method of reading is to place 

one corner of the Velgrid head 1-1/4” from the corner of 

the filter face, take four readings evenly spaced along the 

four foot side, then repeat these reads three additional 

times. This gives a total of eight readings to test the unit. 

All advertised data is based on using the Velgrid with eight 

readings (128 velocity points). ENVIRCO recognizes that 

using eight readings during a cleanroom start-up may be 

time-consuming and recommends  that using four Velgrid 

readings taken on each 2x2 filter section will approximate 

the same as eight readings.

Innovators in Clean Air Technology   |   www.envirco.com   |   Installation, Operation & Maintenance

Содержание MAC 10 LEAC2

Страница 1: ...ENVIRCO Technical Support 800 884 0002 MAC 10 LEAC2 Fan Filter Unit Standard RSRE Models INSTALLATION OPERATION MAINTENANCE MANUAL...

Страница 2: ...ng the Prefilter G4 Pleated 7 Service Removal and Replacement of Standard Filters 8 Service Removal and Replacement of RSRE Filters 9 Service Standard Motor Removal and Installation 10 Service RSRE Mo...

Страница 3: ...LABEL PN 268177 XXX 150412345 BA AS1CH LISTED 2F82 AIR FILTER E152685 Innovators in clean air technology LEAC2 SUITABLE FOR COMMERCIAL OR INDUSTRIAL USE ONLY C R R R Company Purchased From ___________...

Страница 4: ...e A Z in the part number indicates that the unit is special This may indicate a size change from standard or a special filter Please contact the factory for part numbers if this is the situation I n s...

Страница 5: ...stem with eyebolts s hooks and chain Screw the four eyebolts into the nutserts on the lid assembly before lifting into an overhead position See Figure 2 Note Confirm fan dimensions to match T grid dim...

Страница 6: ...s per IEST specifications should be conducted to determine the filter condition and appropriate fan setting Figure 3 Speed Airflow Adjustment ENAC Control Card Optional MAC 10 LEAC2 units will have th...

Страница 7: ...sition Step 3 Remove the prefilter from the snap in frame The beverage board frame has slots that have to be depressed to release the filter from the prefilter housing See Figure 5 above Step 4 After...

Страница 8: ...assembly off the HEPA ULPA filter See Figure 6 Discard the used filter as per requirements of the applicable regulations Note Before replacing with a new HEPA ULPA filter carefully inspect the new fil...

Страница 9: ...reinstalling the removed filter Determine if the gel has lost its ability to seal If so have a certified professional replace the missing dried out and or severely damaged gel Step 5 Place the filter...

Страница 10: ...the four screws mounting the blower bracket to the blower assembly plate and cut cable tie securing blower cable to blower bracket Remove motor mount assembly from plate Step 11 Remove the four screw...

Страница 11: ...or blower and components previously removed in reverse order to complete work Carefully tighten motor mount bracket screws Don t forget to reinstall challenge port tubing WARNING DISCONNECT THE UNIT F...

Страница 12: ...er output NON LAMINAR FLOW AND OR EXCESSIVE CONTAMINATION Step 1 Ensure that no large obstructions are upstream of airflow pattern Step 2 Determine that no other air moving devices are operating in or...

Страница 13: ...CONTROL WHITE GRN YEL BLUE GRN YEL WHITE MAC10 LEAC2 INPUT POWER CAPACITOR Figure 10 Wiring Diagram SSSC Figure 11 WIRING DIAGRAM ENAC BLUE MOTOR BROWN BLACK GRN YEL WHITE GRN YEL WHITE GRN YEL BLUE W...

Страница 14: ...68110 002 268110 003 268109 001 63739 002 268716 115 268716 230 268716 277 268171 115 268171 230 268171 277 ITEM FILTER REPLACEMENT FFU SIZE ACTUAL FILTER SIZE 7A STD FILTER 2X4 23 63 x 47 63 HEPA 99...

Страница 15: ...cords and c modification or repair of the Goods only as authorized by ENVIRCO ENVIRCO does not warrant the Goods or any repaired or replacement parts against normal wear and tear or damage caused by m...

Страница 16: ...ng Grid System Hospital Healthcare Hospital Healthcare IsoClean and IsoClean with Ultraviolet Light AirCeil Hospi Gard Room Pressure Monitor Enviramedic Products HOR Horizontal Flow Enclosure HCF Hori...

Отзывы: