• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent.
If necessary, please use a little pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control keypad directly.
Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.
• Pay attention to the high voltage inside the products, please refer service only to a trained and qualified
professional.
8. Precaustions
• Power Supply : DC 24V (supplied by PS4-24V or PS5-24V)
• Power Consumtion : Standby 60mA; Working status 200mA
• Camera : Pinhole Sharp Color CCD; 420 TV Lines
• Lock Power Supply : 12Vdc, 300mA(Internal Power)
• Number of relay circuits : 2
• Mounting : Surface mounting(DT596/ID), Flush mounting (DT596F/ID)
• Working temperature : -10ºC ~ +45ºC
• Wiring : 2 wires,non-polarityC
• Dimension: 176(H)×90(W)×28(D)mm(DT596/ID), 220(H)×119(W)×52(D)mm(DT596F/ID)
9. Specifications
-15-
-14-
• If an authorized user card is being shown the buzzer will sound of beep+,
and the LED indicator will light up.
• If the unauthorized user card is being shown, the buzzer will sound of beep 3 times.
Show the MASTER CARD
ADD card to ID card window
in standby mode.
beep+,beep
red
(on) (off)
blue
Show the MASTER CARD
ADD card to exit.But it will
return to standby mode if no
operation within 15s.
beep,beep+
red
(off) (off)
blue
Show user cards to be
added, one by one.
beep+
red
(blink) (off)
blue
6.2.5 Authorize master cards:
By default,there are two master cards marked MASTER CARD ADD and MASTER CARD DELETE, but you
should know that the master card can be authorized by users at any time. That means any two user cards
can be authorized to master cards, when registered new master cards, the old master cards will be invalid
automatically.
7. Unlock Operations
When the registered user card has been shown to ID card window, the LED indicator (the first lock : red ;
the second lock : blue) lights up, the buzzer sounds, and the electric door strike will be unlocked.
Note 1 : if the user card controls one lock only,show the user card to release the first lock.red indicator lights up.
Note 2 : if the user card controls two locks,show the user card to ID card window in standby mode,the red & blue
indicator flashes for 1.5s alternately.During this time,press "CALL" button to release the second lock.
Otherwise, release the first lock if there isn't any operation within 1.5 seconds.
• If 10 times unauthorized access cards are continuously attempted, the release function will be forbidden
and the showing card operation will be disabled for 60 seconds.
• If the DIP3 switch is set to 1 and the relay 2 doesn't respond the second lock, in which when showing
user cards controlling two locks or when pressing unlock 2nd on monitor, the monitor, the second lock
whouldn’t release. At this point, after to 10th attempts of showing access card, relay 2 will be closed for
60 seconds and the buzzer will continuously sound about 8 times, if the system is connected to thr alarm,
the alarm function will be activated.
7.1 Unlocking ID Card
Example: Release the first lock
Red LED lights up
(During relay 1 operation)
beep+
red
(on) (off)
blue
Example: Release the second lock
Red LED lights up
(During relay 2 operation)
beep+
red
(off) (on)
blue
• You can activate the electric door strike by pressing the request to exit button connected to the unit.
Pressing request to exit button 1 releases relay 1, and pressing request to exit button 2 releases relay
2.(The unlock function will work when the request to exit button is being pushed, even while the
proximity access is forbidden.