background image

 
 
 
 

 

 

PRO-DPC

 

Installation and Setup Guide with PRO-AS7

 

Issue:

 

003

 

 

Содержание PRO-DPC

Страница 1: ...PRO DPC Installation and Setup Guide with PRO AS7 Issue 003 ...

Страница 2: ...8th Edition Regulation 444 MEASURES AGAINST ELECTROMAGNETIC DISTURBANCES imposes requirements for segregation of circuits IET Wiring Regulations 18th Edition Regulation 528 PROXIMITY TO WIRING SYSTEMS TO OTHER SERVICES imposes requirements for segregation of door entry access control circuits Band I 230VAC mains circuits Band II and other higher voltage circuits IET Wiring Regulations 18th Edition...

Страница 3: ... Systems without an Entrotec Connect Server 11 Provisioning Systems with an Entrotec Connect Server 13 Provisioning Systems with an Entrotec Connect Server Installed Retrospectively 14 9 Configure 15 Block Name 15 Video and Audio Settings 15 Lock Release Time 16 Coded Access 16 10 Apartment Station Configuration 17 Required Info 17 Factory Default Settings 17 Initialise 17 Provision 19 Configure 2...

Страница 4: ...Cable A Door controller with PSU to each call panel 2x Cat5e or Cat6 B Lock Relay to locks 2x 1 5mm multi stranded flex or singles route through any exit fire switch or break glass for fail safe operation C Lock Relay to exit switch 1 Pair UTP 2 cores Cat5e or Cat6 D Lock Relay to fire switch 1 Pair UTP 2 cores Cat5e or Cat6 Typical Configuration FIGURE 1 1 NOTE Refer to the PRO DC Door Controller...

Страница 5: ...lied Microphone Panel Camera Display Speaker Keypad RFID Proximity Reader 2 1 2 Back View FIGURE 2 2 DO NOT USE RS485 to Door Controller Tamper Switch Relay Output Ethernet to Door Controller Alarm Inputs 12VDC from Door Controller PSU A B C D E F G A B C D E F G A B C D E F G A B C E F D G ...

Страница 6: ... Detail RS485 to Door Controller 1x Cat5e or Cat6 1 Pair UTP RS485A RS485B 1 2 12VDC from Door Controller PSU DC connector supplied 1 Pair UTP 12v White 2 Pair UTP 0v Black Ethernet to Door Controller 1x Cat5e or Cat6 RJ45 T568B FIGURE 3 2 A B C Up to 90M A B C ...

Страница 7: ...rk Settings on Device Before initialising a Call Panel the default IP address should be configured to avoid conflicts with other devices with the same default settings To apply the new network settings enter the programming menu on the Call Panel by pressing the call button then the Device Admin Code default 888888 then the call button FIGURE 5 1 i The first option in the menu IP Config is selecte...

Страница 8: ...t take up to 2 minutes 6 Initialise NOTE Settings differ between systems WITH and WITHOUT an Entrotec Connect Server For systems without an Entrotec Connect Sever one Call Panel on the system is assigned as the SIP server Connect to Web Service and Initialise Device i Connect a laptop or PC to the same network as the Call Panel ii Assign your PC or laptop an IPv4 address from the same range used b...

Страница 9: ...ress Next WARNING It is important to choose a secure password and manage it correctly If a password is forgotten the device may have to be restored to default settings This may result in data loss v Enter a recovery email address optional and press Next FIGURE 6 2 ...

Страница 10: ...gn your PC or laptop an IPv4 address from the same range used by the door entry system iii Use a web browser and enter the IP address of the Call Panel in to the address bar iv Login to the call panel using the following credentials Username admin Password password setup during initialisation Section 6 1 FIGURE 7 1 ...

Страница 11: ...n Entrotec Connect Server For systems without an Entronet Connect Sever one Call Panel on the system is assigned as the SIP server Sub Call Panels and Apartment Stations register to this Main Call Panel 8 1 1 Configure SIP Server Settings for Sub Call Panels NOTE This section is for Sub Call Panels only For Main Call Panel Setup continue to section 9 i Log in to the Sub Call Panel ii Navigate to N...

Страница 12: ...ress Save NOTE The device will reboot if the SIP Server is enabled or disabled This might take up to 2 minutes 8 1 2 Configure SIP ID i Login to the Call Panel as described in section 7 ii Navigate to Local Settings Basic iii Set the Block Name the text displayed on the first line when the panel is in its idle state iv Set the Door No each Call Panel on a block should have a unique number v Press ...

Страница 13: ...ce SIP Server is enabled or disabled 8 2 2 Configure the Alternate SIP Server After applying the SIP server settings in Section 8 2 1 you can configure an alternate SIP Server The Alternate SIP server will take over from the original in case of any down time The panel configured to be the Alternate SIP Server is typically the main door panel in the system FIGURE 8 5 This can be configured followin...

Страница 14: ...er Installed Retrospectively When planning to install the ECS at a later stage the door entry system can be configured so that the main door panel will work temporarily as the SIP server Once the server is installed it will automatically take over from the main door panel and start running the door entry system For configuring e apartment stations for this system setup please go to section 10 4 1 ...

Страница 15: ...state iv Press Confirm FIGURE 9 1 Video and Audio Settings i Login to the Call Panel as described in section 7 ii Navigate to Local Settings Video Audio iii These settings are application specific dependant on the location of the Call Panel FIGURE 9 2 NOTE The maximum resolution is 720P The PRO AS7 Apartment Station display resolution is 480x800 therefore it may be most efficient to use the WVGA V...

Страница 16: ...o Local Settings Access Control RS485 vi Set the Unlock Response Interval and Unlock Time for the desired lock release time vii Press Save these settings update the parameters for the remote lock relay in the connected Door Controller FIGURE 9 4 Coded Access i Login to the Call Panel as described in section 7 II Navigate to Local Settings Access Control Local iii Enter a 6 8 digit access code in t...

Страница 17: ... 192 168 1 1 Device User Passcode 1 2 3 4 5 6 Flat No 9901 Initialise 10 3 1 Set Admin Password Settings on Device i When the device is first powered it will request an initial Device Admin Password and recovery email address FIGURE 10 1 ii Enter the Password which must be a 6 digit number WARNING It is important to choose a secure password and manage it correctly iii Enter the recovery Email this...

Страница 18: ...nds FIGURE 10 3 ii When the Password Verification screen appears enter the device admin password setup in during initialisation iii Press OK FIGURE 10 4 iv The admin menu will open in the Network tab Set the IP Address Subnet Mask and Gateway address by pressing on the segment you wish to change v Press OK to save FIGURE 10 5 ...

Страница 19: ... identifies the apartment station as the Master within the same property Any additional Slaves must be identified e g 23 1 for slave 1 23 2 for slave 2 FIGURE 10 6 iii Press OK to save iv Navigate to the SIP Server tab FIGURE 10 7 v Enter the following SIP Details a Systems WITHOUT EC Server Server IP Main Call Panel IP Network Port 5060 b Systems WITH an EC Server Server IP Entrotec Connect Serve...

Страница 20: ...he Enable switch is OFF set it to ON after making any changes iv If the Enable switch is ON set it to OFF then ON again This forces a synchronisation of settings between the apartment station and the door panel this takes a few seconds to complete Configure 10 5 1 Accessing Device Settings i From the home screen short press Settings FIGURE 10 9 v When the Password Verification screen appears enter...

Страница 21: ... is assigned to the main call panel Required Info To register devices to the Main Call Panel SIP Server the following is required SIP ID of the Sub Call Panels Door No SIP ID Apartment Stations Flat No IP Address Username Password Port Number etc of any separate IP Cameras Register Devices 11 2 1 Register Apartment Stations i Login to the Main Call Panel as described in section 7 vii Navigate to S...

Страница 22: ...peat steps viii xi for additional Apartment Stations 11 2 2 Register Sub Call Panels i Login to the Main Call Panel as described in section 7 ii Navigate to System Settings Door No Management iii Press Add FIGURE 11 3 iv In Rec No Enter the Door No set in section 8 1 1 v Enter the Block Name vi Press Save FIGURE 11 4 Repeat steps ii vi for additional sub call panels ...

Страница 23: ... 0 vii Navigate to System Settings Camera Settings viii Choose the first unused entry and press Modify FIGURE 11 5 ix Enter a user friendly Camera Name x Enter the IP Address for the camera and device specific settings as required xi Press Save FIGURE 11 6 Repeat steps viii xi for additional cameras Notes ...

Страница 24: ... to the Main SIP Server Call Panel as described in section 7 xii Navigate to System Settings Status FIGURE 11 7 All SIP devices registered to the Main Call Panel are displayed If a device has gone offline it will display the last Off Time Notes ...

Страница 25: ...Device Registration 25 Device List IP Address Block ID SIP ID Type Description 192 168 1 111 1 8001 Call Panel Ashwood Court Front Door ...

Страница 26: ...Notes 26 ...

Страница 27: ...Notes 27 ...

Страница 28: ...Entrotec Ltd 5 Ashwood Court Oakbank Livingston EH53 0TL Telephone 01506 886 230 Support 01506 886 235 www entrotec com ...