Instructions for Installation of the Door Closers (Standard Type)
Force 2/4
Force 3
220mm (Force 2/3, Door Width≤950mm, Max 180°)
Hinge
Hinge
82
Weak
230
45
104
39
2-#10x5/8”
UNDERSIDE
OF FRAME
SET TO TOP
OF DOOR
4-#10x2”
Weak
Use this side of template for clockwise opening door
(RIGHT HAND OPENING)
245mm (Force 4, Door Width≤1100mm, Max 180°)
Determine the installation position of the
door closer place the templet on the closed
door and the top jamb, and make holes in
them with a punch or other proper tool
Templet
Fix the link shoe to the top jamb
Fit the lever to the pinion shaft and fix it
firmly with the screw
Mount the closer on the door
Adjust the link length so that the link makes
a right angle with the top jamb, and fix with
the lock nut
FIX PINION CAP TO CLOSER BODY
Adjust the closing speed.
The door closer closes the door at two differ-
ent speeds.
The first speed can be controlled by the No.1
speed adjusting valve, and the second speed,
by the No. 2 speed adjusting valve
LINK ARM MUST BE SET 90° TO
FRAME WITH DOOR CLOSER
Link shoe
Door closer
Lever
Mounting screw
CLOSING
LATCHING
SLOW
No.1 CLOSING
No.2 LATCHING
FAST