e Loosen the door stop arm.
f
Mount the door stop arm on the splines a), as close as possible to the stop block b). Fine-adjust
if necessary with the screw on the stop block c).
a
b
c
g Close the door by turning the potentiometer SPTE to 0° and let the door close.
Note! Impulses are not accepted if SPTE is more than 0°.
0°
SPTE
1
4
2
3
Door stop arm
1
Fixing screw
2
Stop block
3
Fine-adjustment screw
4
55
Issue 2014-11-24
1005088-EMEI-11.0
11 Start-up