5
NOTE: If operator is installed on aluminum framing high and low voltage wiring can be routed
through vertical and horizontal tubes.
Push Header
The header box on push installations is mounted flush to the bottom of the doorjamb header. It may
require solid backing material to compensate for the thickness of the doorframe. Insure before fastening
Header Box to the doorframe that your access holes for high and low voltage wires match. Header box
should be centered
between doorjambs. Header size is equal to door opening plus 3”. This allows for a
1-
½” space on either side of the Header Box to anchor the Header Box properly to the frame. The
Header Box should be anchored with a minimum of (6) -
#14 x 1” Pan Quad Type A screws (provided.)
2 screws should be used at either end (1/2" in from end plate) to fasten directly to the doors
vertical jambs.
2 more screws fasten the Header Body to the bottom of the doorframe approximately 10" in
from either end. The header should support 200lbs.
Pull Header
Note: Header on pull applications must be mounted so the main drive pinion safety washer and machine
screw are above the top of the door.
Insure before fastening Header Box to the doorframe that your holes for high and low voltage wires
match. Header box should be centered between doorjambs and
1 3/8" above the bottom of the
doorframe
(
FIGURE 2
). Header size is equal to door opening plus 3”. This allows for a 1-½” space on
either side of the Header Box to anchor the Header Box properly to the frame. The Header Box should
be anchored with a minimum of 6 -
#14 x 1” Pan Quad Type A screws (provided).
Figure 1
Содержание Ditec FA-8