background image

Ditec EL31R

IP1851EN

Installation Manual for control panel for 24V automations with built-in radio.

www.ditecentrematic.com

POWER

SA

11

IN

Limit switch

Limit switch

Acce

ssories outpu

t

12

VA

A

VC TC R1

AUX

A

N

T

B

A

T

SAFETY

24V~

1 5 9 13 20

0 1 6 8 41

C NO

11

12

0

14 0

PRG

COM

ENC

JR1

1

ON

2 3 4 5 6

B

1

ON

2 3 4 5 6 7 8

EL31R

SIG

-M

+M

Power supply

Step-by-ste

p

Sa

fe

ty sto

p

Sa

fe

ty r

eopening

Stop

Saf

ety test

Flashing light

Gate open indicator light

Partial opening

GOL4

F1

Transformer

Safety switch

24V=             

Motor

BATK3

Содержание Ditec EL31R

Страница 1: ...t switch Accessories output 12 VA A VC TC R1 AUX A N T B A T SAFETY 24V 1 5 9 13 20 0 1 6 8 41 C NO 11 12 0 14 0 PRG COM ENC JR1 1 ON 2 3 4 5 6 B 1 ON 2 3 4 5 6 7 8 EL31R SIG M M Power supply Step by step Safety stop Safety reopening Stop Safety test Flashing light Gate open indicator light Partial opening GOL4 F1 Transformer Safety switch 24V Motor BATK3 ...

Страница 2: ...2 IP1851EN 2013 05 06 ...

Страница 3: ...hes 10 7 4 Jumper 10 7 5 Signals 11 8 Radio 12 9 Working modes for sliding gates 13 10 Start up 13 10 1 CROSS start up 13 10 2 QIK start up 14 11 Troubleshooting 15 12 Application example for sliding gates 16 13 Application example for barriers 16 14 Application example for parallel automations 17 15 Example of operator present function mode 18 Key i This symbol indicates useful information for th...

Страница 4: ...olar dis connection switch with minimum contact gaps of 3 mm must be included in the mains supply Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a suitable overcurrent cutout When requested connect the automation to an effective earthing system that complies with current safety standards During installation maintenance and repair operat...

Страница 5: ... Storage module 3M1CR3 3M1CR5 3M1CR5C5 3M1CR7 3M1CR7C5 3M1QK 3M1QKC7 Power supply 230 V 50 60 Hz 230 V 50 60 Hz 230 V 50 60 Hz 230 V 50 60 Hz F1 fuse F1 6A F1 6A F2A F1 6A Motor output 24 V 8 A 24 V 9 5 A 24 V 14 A 24 V 7 A Accessories power supply 24 V 0 3 A 24 V 0 3 A 24 V 0 3 A 24 V 0 3 A Temperature min 20 C max 55 C min 20 C max 55 C min 20 C max 55 C min 20 C max 55 C Degree of protection IP...

Страница 6: ...e one performed before the stop 1 20 N O AUTOMATIC CLOSING With DIP3B OFF permanent closing of the contact enables automatic closing 0 11 N C CLOSING LIMIT SWITCH Opening of the contact stops the closing operation 0 12 N C OPENING LIMIT SWITCH Opening of the contact stops the opening operation 41 SAFETY TEST With DIP6A ON connecting terminal 41 enables a safety edge test cycle before every operati...

Страница 7: ... re establish or until the battery voltage drops below the safety threshold The panel turns off in the last case WARNING the batteries must always be connected to the control panel for charging Periodically check the efficiency of the batteries N B the operating temperature of the rechargeable batteries is approximately 5 C 40 C 1 5 9 13 20 24 V 3 W Automation status light proportional The light g...

Страница 8: ... the safety threshold The panel turns off in the last case WARNING the batteries must always be connected to the control panel for charging Periodically check the efficiency of the batteries N B the operating temperature of the rechargeable batteries is approximately 5 C 40 C 1 5 9 13 20 24 V 3 W Automation status lamp proportional The light goes off when the automation is closed The light comes o...

Страница 9: ...by step Opening DIP2A Selecting opening direction The opening direction is in tended by viewing the automa tion from the side being examined Opening to the right Opening to the left DIP3A Automatic closing time restore 50 100 DIP4A Automation status at power on Indicates how the control panel considers automation when powered up Open N B with limit switches installed we rec ommend setting DIP4A OF...

Страница 10: ...and electric block Preflashing for 3 seconds Enabled only with automatic closing with TC 3 s DIP6A Safety test terminal 41 Disabled Enabled DIP B Description OFF ON DIP1B Reversal safety contact operation With automation stopped and contact 1 8 open opening operations are permitted With automation stopped and 1 8 open all operations are disabled DIP2B Command functions 1 6 Closing Stop DIP3B Prefl...

Страница 11: ...tch SA At least one of the safety contacts is open or DIP6A selection is not consistent with the connection of terminals 6 8 Safety test failure terminal 41 Operations count performed only when control panel is switched on 1000 operations 10000 operations 11 0 11 limit switch contact is open 12 0 12 limit switch contact is open SIG Transmitter enabling storage phase Radio transmission of a stored ...

Страница 12: ...edure 10 seconds after the last transmission or you can press the PRG key again the SIG LED goes off Up to four CH keys of a single remote control can be stored If only one any CH key of the remote control is stored command 1 5 step by step opening is carried out If 2 4 CH keys of a single remote control are stored the functions matched with the CH keys are as follows CH1 command 1 5 step by step ...

Страница 13: ...per for NC safety contacts 2 Check that the storage module corresponding to the type of application selected is correctly plugged in 3 Adjust the opening and closing stop limit switches if any N B limit switches must be kept pressed until the operation has been completed 4 Set TC MAX and R1 50 Select the desired opening direction with DIP2A Set DIP4B OFF and DIP6B OFF 5 Manually move the sliding g...

Страница 14: ...desired opening direction with DIP2A Set DIP4B OFF and DIP6B OFF 5 Manually move the barrier bar and make sure it is correctly balanced 6 Switch on and check the automation is operating correctly with the subsequent opening and closing commands Check that the limit switches are activated if used 7 Connect the safety devices removing the relative jumpers and check they function correctly 8 If desir...

Страница 15: ...rs on the built in radio If there is a fault with the radio receiver that is built into the control panel the remote control codes can be read by removing the storage module Photocells activated SA LED on Check that the photocells are clean and operat ing correctly The automatic closing does not work Check that the TC trimmer is not set at the maximum or check the DIP3B ON setting The external saf...

Страница 16: ...nnect the opening and closing limit switch NC contacts to terminals 0 11 12 With this configuration the barrier stops when the limit switches are activated Example 2 The remote control can be used with step by step functioning and at the same time terminal 5 with opening function by making the connections indicated and setting DIP1A OFF Closing limit switch Opening limit switch 1 5 9 13 20 0 1 6 8...

Страница 17: ...s with a single remote control do not use the radio receivers on the control panels JR1 OFF but insert a BIXLR22 radio receiver Adjust TC VA and VC trimmers in the same position on both control panels i N B the opening and closing movements may not be synchronised A B JR1 JR1 A B BIXLR22 ANT OUT2 1 2 3 4 1 2 3 4 JR1 JR2 1 5 9 13 20 0 1 6 8 41 1 5 9 13 20 0 1 6 8 41 A 1 ON 2 3 4 5 6 B 1 ON 2 3 4 5 ...

Страница 18: ...the opening 1 5 and closing 1 6 controls function only if held in the pressed position and the au tomation stops when the controls are released The automatic closing and radio controls are disabled Closing limit switch Opening limit switch 1 5 9 13 20 0 1 6 8 41 C NO 11 12 0 14 0 VA VC TC R1 MAX 50 50 A 1 ON 2 3 4 5 6 B 1 ON 2 3 4 5 6 7 8 DIP2B OFF DIP1A ON Closing limit switch Opening limit switc...

Страница 19: ...ication have been drawn up with the greatest care Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publication We reserve the right to make changes without prior notice Copying scanning and changing in any way are expressly forbidden unless authorised in writing by Entrematic Group AB ...

Страница 20: ...IP1851EN 2013 05 06 Entrematic Italy S p A Via Mons Banfi 3 21042 Caronno P lla VA Italy Tel 39 02 963911 Fax 39 02 9650314 www ditecentrematic com ...

Отзывы: