46
IP1967EN - 2016-08-01
6. Output and accessories
Output
Value - Accessories
Description
0 1
+
-
24 V / 0,5 A
Power supply output for external accessories, including automa-
tion status lamp. Electronically protected output.
1
13
24 V / 3 W
Automation status lamp (proportional).
The light switches off when the automation is closed; the light switches
on when the automation is open; the light flashes with a variable
frequency while the automation is operating.
0
14
LAMPH
24 V / 25 W
Flashing light (LAMPH).
Selecting
, the flashing
light activates simultaneously with the opening and closing ope-
ration.
NOTE: with automatic closing enabled, there is a pre-flashing of 3
s that cannot be regulated.
0
14
24 V / 25 W max.
Courtesy light.
Selecting
, it is possible to con-
nect a courtesy light that activates each time a total or partial
opening command or closing command is received.
The duration of the light can be regulated via the adjustment
and
.
0
15
24 V / 1,2 A
Electric block 24V.
0
15
12V~ / 15 W
Electric lock 12 V.
Connect the supplied 8.2 Ω / 5W resistance in
series.
AUX
The control panel is fitted with a housing for a plug-in card, such
as radio receivers, magnetic spirals, etc. The action of the card
can be selected via the selection
.
WARNING: the plug-in cards must be inserted and removed with the
power supply disconnected.
COM
Storage
module
The storage module allows remote controls to be stored and the type
of control panel application to be defined (see TECHNICAL DETAILS
on page 4).
If the control panel is replaced, the storage module being used can
be inserted in the new control panel.
WARNING: the storage module must be inserted and removed with
the power supply disconnected.
BAT
BATK1
2 x 12 V / 2 Ah
Battery operating.
The batteries are kept charged when the power
supply is on. If the power supply is off, the control panel is powered
by the batteries until power is re-established or until the battery
voltage drops below the safety threshold. If this occurs, the control
panel turns off.
WARNING: the batteries must always be connected to the control
panel for charging. Periodically check the efficiency of the batteries.
NOTE: the operating temperature of the rechargeable batteries is
approxi5°C/+40°C.