Display

Description

RC - Loading configuration.

It is possible to load the configurations previously saved, or load the predefined set-
tings available in the memory positions 

 and 

. The predefined set-

tings are as follows:

          : OBBI

          : FACIL

          : LUXO

          : ARC

Loading a predefined setting, standard average values are automatically set for certain 
parameters (type of automation, operation speed, operation times and deceleration 
times).

RL - Loading the last configuration set

CU - Viewing the electronic panel’s firmware version.

= Release 0.3.4 (example)

2 s

2 s

NOTE: the control panel automatically saves the last configuration set, and 

keeps it memorised in the storage module. In the event of a fault or the re-
placement of the control panel, it is possible to restore the last configuration of 
the automation by inserting the storage module and loading the last configura-

tion set.

i

i

Note: view only.

WARNING: it is possible that, owing to the type of automation and control panel, certain 
menus are not available.

(EXAMPLE)

Содержание Ditec E2H

Страница 1: ... JR5 COM DOWN ENTER ESC 24V L N POWER TRF AUX JR1 BAT ANT GOL4 24V 24V F U S E L N 36 35 34 33 32 31 1 5 13 9 15 14 0 1 5 20 0 1 6 0 1 8 Power supply Motor 1 Motor 2 Power unit Memory card Flashing light Electric lock Stop safety contact Lamp Step by step Step by step Partial opening Stop Output 24 V Output 24 V Reversal safety contact ...

Страница 2: ... door wings 72 14 Example application of automation with one swinging door wings 73 This symbol indicates instructions or notes regarding safety issues which require particu lar attention This symbol indicates instructions or notes intended for technical and expert personnel This symbol indicates options and parameters which are only available with the indicated item This symbol indicates options ...

Страница 3: ...hat there is an adequate residual current circuit breaker and a suitable overcur rent cut out upstream of the electrical installation in accordance with Good Working Methods and with the laws in force When requested connect the automation to an effective earthing system that complies with current safety standards During installation maintenance and repair operations cut off the power supply before...

Страница 4: ... r r r r ar r ar r r r r r r ar r r r a ar r r r r ar a ar r ar r r r r r a ar r r a a a ar r r a a a ar r r a a ar r r r a a a a ar r r r ar r r ar r r ar a a ar rco co co co co co co co co co o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o Zin Zin i i Zi Zi i i Zi i i Zi i Zi i i i i i Zi i i ...

Страница 5: ...ric cable and connect to the terminals L brown N blue yellow green in the automation Secure the cable using the special cable clamp and remove the outer sheath near the terminal only Connection to the mains power supply in the section outside the automation is made with independent channels and separated from the connections to the control and safety devices The channels must penetrate a few centi...

Страница 6: ...ation Selecting with the automation idle the opening of the contact prevents the closing opera tion only 1 9 N C STOP Opening the safety contact stops the current operation Note the flashing light flashes 1 9 N O HOLD TO RUN FUNCTION Selecting and the permanent opening of the safety contact enables the hold to run function In this state the opening 1 5 and closing 1 6 controls function only if held ...

Страница 7: ...ls an alarm mes sage is visualised on the display 1 6 N C OPENING SAFETY DEVICE Selecting connect the output contact of device SOFA1 SOFA2 to terminals 1 6 on the control panel in series with the photocell output contact if installed 1 8 N C REVERSAL SAFETY CONTACT Selecting connect the output contact of device SOFA1 SOFA2 to terminals 1 8 on the control panel in series with the photocell output c...

Страница 8: ...ect the supplied 8 2 Ω 5W resistance in series AUX The control panel is fitted with a housing for a plug in card such as radio receivers magnetic spirals etc The action of the card can be selected via the selection WARNING the plug in cards must be inserted and removed with the power supply disconnected COM Storage module The storage module allows remote controls to be stored and the type of contro...

Страница 9: ... and parameters present Maintenance mode It is possible to visualize and modify the values and pa rameters present The en try in maintenance mode is indicated by the permanent switching on of the right hand point JR5 Built in radio receiver Disabled Enabled LED ON Flashing POWER 24 V power supply Indicates the transfer of data during DMCS programming ...

Страница 10: ...us pressing of the keys S and T performs a POWER RESET command Interruption of the power supply and restart of the automation 9 Adjustment 9 1 Switching on and off 9 2 Key combinations NOTE before making all the automation adjustments insert the dedicated memory module and press or load the configuration applying to the automation installed see options When the power is connected or in the case of ...

Страница 11: ...Operations The menu allows you to manage the radio operations of the control panel SF Special Functions The menu allows to set the password and manage the special functions in the control panel CC Cycles Counter The menu allows to visualise the number of operations carried out by the automation and manage the maintenance interventions AP Advanced Parameters The menu allows to visualise and modify ...

Страница 12: ... open This selection loads predefined values for certain standard parameters AC enabling of automatic closing enabled TC setting of automatic closing time 1 minute C5 step by step opening command operation step by step RM remote control operation step by step AM AUX coupling board operation step by step SS selection automation status at start up closed This selection loads predefined values for cert...

Страница 13: ...isplay visualizes the message OFF ON NW Selecting number of door wings 1 2 AC Enabling of automatic closing OFF ON C5 Step by step opening command operation STEP BY STEP OPENING RM Radio receiver functionality STEP BY STEP OPENING AM AUX coupling board operation STEP BY STEP OPENING SS Selection of automation status at activation Indicates how the control panel considers the automation at the time...

Страница 14: ...st be ex posed to the same ambient temperature as the motors OFF ON 64 Functioning of safety stop closing command STOP CLOSING P2 Functioning of partial opening command contact 1 20 P3 Partial opening command 1 2 Enablement of automatic closing PARTIAL OPENING AUTOMATIC CLOSING EO Functioning of electric lock electric brake SC Functioning of electric lock functioning time set via adjustment SF Fun...

Страница 15: ... is fitted with a safety device which when it detects an obstacle in opening stops the movement with a disengagement operation in closing before the deceleration inverts the move ment in closing during the deceleration stops or inverts the movement according to the type of limit switch installed 0 99 RP Adjustment of the partial opening measurement Adjusts the percentage of operation in relation to...

Страница 16: ...ment PX Proximity limit switc after the activation the door wing continues as far as the end stop NONE STOP DECELERATION PROXIMITY VA Setting opening speed V MIN MAX VC Setting closing speed V MIN MAX VR Setting acquisition manoeuvre speed V MIN MAX TC Setting automatic closing time s Adjustment occurs with intervals of varying sensitivity from 0 to 59 sec with 1 sec intervals from 1 to 2 min with...

Страница 17: ...ervals from 2 to 3 min with 1 min intervals NO Disabled ON Permanent switch on switch off using radio command i WARNING the courtesy light switches on at the start of each operation DISABLED 1 SECOND 1 MINUTE 3 MINUTES 59 SECONDS 2 MINUTES ON LG Setting switch on time for independent light s Adjustment occurs with intervals of varying sensitivity from 0 to 59 sec with 1 sec intervals from 1 to 2 m...

Страница 18: ...stment in seconds of the lead time for the switch on of the flashing light in relation to the start of the mano euvre from a voluntary command MIN MAX WC Setting closing pre flashing time s Adjustment in seconds of the lead time for the switch on of the flashing light in relation to the start of the mano euvre from a voluntary command MIN MAX WARNING it is possible that owing to the type of automatio...

Страница 19: ... acci dently memorized OFF ON MU Setting the maximum number of transmitters that can be memorized on a memory module It is possible to memorise up to 100 or 200 rolling code transmitters 200 100 use the keys S and T to select the required function press the ENTER key to confirm 9 7 Second level menu RO Radio Operations It is possible to directly access the Transmitter memory storage menu with the d...

Страница 20: ...ction NONE CLOSING PARTIAL STOP OPENING STEP BY STEP COURTESY LIGHT RK Navigation via transmitter keyboard With the display switched off quickly type the sequence of keys 3 3 2 4 1 using the desired memorized transmit ter Note it is recommended to use a dedicated transmitter To test the new configuration switch off the display and give an open command using key 3 1 2 3 4 Navigation via transmitter ...

Страница 21: ... menu SF Special Functions use the keys S and T to select the required function press the ENTER key to confirm The procedures to activate the functions are described in the table It is possible to annul the set password by selecting the sequence JR1 ON JR1 OFF JR1 ON i i Note this is only possible when the password is not set The setting of the password prevents unauthorised personnel from accessin...

Страница 22: ...times and deceleration times RL Loading the last configuration set CU Viewing the electronic panel s firmware version Release 0 3 4 example 2 s 2 s NOTE the control panel automatically saves the last configuration set and keeps it memorised in the storage module In the event of a fault or the re placement of the control panel it is possible to restore the last configuration of the automation by insert...

Страница 23: ...ation is closed it flashes 4 times every 60 minutes DISPLAY INDICATOR FLASHING CP View partial manoeuvres counter 71 625manoeuvres example ZP Resetting partial manoeuvres counter To ensure correct operation it is recommended to reset the partial manoeuvres counter after each maintenance intervention after each setting of the maintenance alarm interval 2 s EXAMPLE EXAMPLE 2 s 9 9 Second level menu C...

Страница 24: ...ON S5 Duration of STOP in step by step sequence with com mands 1 5 TEMPORARY PERMANENT R9 Enablement of automatic closing after command 1 9 STOP When enabled ON after a command 1 9 the automation carries out the automatic closing if enabled after the set time OFF ON TA Adjustment acceleration phase FAST SLOW 9 10 Second level menu AP Advanced Parameters i WARNING the gap between the adjustment val...

Страница 25: ...ime during opening s MIN MAX CB Deceleration braking time during closing s MIN MAX DS Setting of display viewing mode 00 No display 01 Commands and safety devices with radio test see paragraph 10 2 02 Automation status see paragraph 10 1 03 Commands and safety devices see paragraph 10 2 NONE STATUS RADIO TEST COMMANDS D6 Selecting device connected to terminals 1 6 NO None SE Safety edge PH Photoce...

Страница 26: ...rses the movement STOP DISENGAGE STOP OPENING STOP RESUME REVERSE CLOSING TN Setting intervention temperature for NIO anti freeze system C Adjustment of the working temperature of the control panel DOES NOT refer to outside temperature 6 ºC 6 ºC TB View control panel temperature DO NOT USE OFF ON OL Selecting open gate indicator light mode When set ON the light is switched off when automation is c...

Страница 27: ...ation status display 10 2 Commands and safety devices display i i i WARNING it is possible that owing to the type of automation and control panel certain menus are not available WARNING the automation status display mode is visible only with the Display viewing mode set on 02 WARNING the commands and safety device display mode is only visible with the Display viewing mode set on 01 or 03 Display D...

Страница 28: ...ey not memorised CX AUX coupling board command reception F1 Generic limit switch relating to motor 1 F2 Generic limit switch relating to motor 2 O1 Detection of an obstacle by motor 1 or arrival of motor 1 at mechanical stop O2 Detection of an obstacle by motor 2 or arrival of motor 2 at mechanical stop RV Enablement disablement of built in radio receiver via JR5 MQ Acquisition of mechanical stops...

Страница 29: ...h MG Irregular functioning of motor 2 clo sing limit switch Check the connection of the motor 2 clo sing limit switch MH Incorrect wings overlap Verify that the motor which opens first M1 is connected as shown in fig 1 MI Detection of third consecutive obsta cle Check for the presence of permanent ob stacles along the automation path Radio operations alarm R0 Insertion of a memory module contai ning...

Страница 30: ...rd is not in serted check the safety test is disabled A3 Failure of test of safety sensor on contact 8 Check the device SOFA1 A2 is working correctly If the supplementary SOF card is not in serted check the safety test is disabled A7 Incorrect connection of contact 9 to terminal 41 Connect the 1 9 contact Service V0 Request for maintenance interven tion Proceed with the scheduled maintenance inter...

Страница 31: ...ive an opening command and verify that the automation carries out the operation at reduced speed stopping at the mechanical doorstops during the opening phase 11 9 Load the predefined setting most suitable for system available in the menu 11 10 If limit switches are used define their use by means of settings and 11 11 In order to save the configurations in the memory module it is necessary to set 11 ...

Страница 32: ...an and operating correctly The automatic closing does not work Issue any command If the problem persists contact Technical Service Faulty motor Check motor connection if the problem persists contact Technical Service The external safety devices are not activated Incorrect connections be tween the photocells and the control panel Check that is dis played Connect NC safety contacts together in serie...

Страница 33: ...e module Switch the automation off and plug in the correct storage module Check the correct memorisa tion of the transmitters on the built in radio If there is a fault with the radio receiver that is built into the control panel the remote control codes can be read by removing the storage module ...

Страница 34: ...ation with mechanical door stops in opening and closing phases without the use of electric limit switches Fig 13 2 Installation with mechanical door stop in closing phases with the use of electric limit switches 36 35 34 33 32 31 24V 24V Motor 1 Motor 2 1 2 36 35 34 33 32 31 24V 24V Motor 1 Motor 2 1 2 Fig 13 1 Fig 13 2 13 Example application of automation with two swinging door wings ...

Страница 35: ...g 14 1 Installation with mechanical door stops in opening and closing phases without the use of electric limit switches Fig 14 2 Installation with mechanical door stop in closing phases with the use of electric limit switches 33 32 31 24V 1 Motor 1 33 32 31 1 24V Motor 1 Fig 14 1 Fig 14 2 14 Example applications for automation with one swinging door wing ...

Страница 36: ...IP1967EN 2016 08 01 Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www entrematic com ...

Отзывы: