background image

11  Aligning the Infrared Safety Beam

The safety beam has two components, a sender and a receiver. The sender produces a narrow infrared beam 

that travels across the bottom of the door opening to the infrared receiver. If an object blocks the infrared beam 

while the door is closing, the door will stop, then reverse and fully open (the operator’s light will flash three times).
As a safety feature, the operator will ignore signals from all remote controls if the door is open and the infrared 

safety beam is blocked or out of alignment. In this case, the door can be forced closed by pressing and holding 

the wall station’s up/down arrow pushbutton (be sure the door area is in clear view).

Safety Beam Test

1  Check that the operator has power. The green lights 

on the sender and receiver should be lit.

2  If the receiver’s green light is on, but the red light is 

off, the receiver has power but is not detecting the 

infrared beam from the sender. The red light might 

flash when the beam is partially detected. This can 

be caused by mis-alignment or something blocking 

the beam. Adjust the safety beam sender and receiver 

while watching the receiver’s red light (stay out of the 

beam while aligning it). When the red light stays on, 

rotate the sender towards the ceiling and stop when 

the red light on the receiver begins to flicker. Rotate 

the sender back towards a horizontal position with the 

floor and stop as soon as the red light on the receiver 

lights solid. The beam is now properly aligned.

SAFETY BEAM INDICATOR TABLE

GREEN ON

POWER ON

GREEN OFF

POWER OFF

RED ON

BEAM OK - NO BLOCKAGE

RED OFF

BEAM BLOCKED OR MIS-ALIGNED

RED FLASHING

BEAM ALIGNED POORLY

 

NOTE:

 If the receiver’s red light remains off, check 

for: 1) Dirt on the receiver’s lens, 2) Sunlight shining 

into the receiver’s lens, 3) A short in the safety beam 

wiring (from staples or at the operator terminals).

3  With the door closed and the operator disengaged 

from the door, press the wall station’s UP/DOWN 

ARROW button to move the traveler (the part on 

the belt or chain that the trolley engages with) to 

the up position (away from the door). 

NOTE: Do not 

cycle the operator to full travel without the door 

connected.

4

 

Push the wall station’s UP/DOWN ARROW button again. 

While the traveler is moving to the down position (toward 

the door), block the safety beam. 

THE TRAVELER MUST 

STOP, THEN REVERSE TO THE UP POSITION.

 The 

operator’s light and red light should flash three times.

5 Place an object in the path of the safety beam. 

Check that constant pressure is required on the 

wall station’s UP/DOWN ARROW button to cause the 

traveler to move toward the down position. Release 

the pushbutton 

before

 the operator stops; check that 

the traveler returns to the up position.

 

NOTE:

 The garage door operator will not respond 

to a CLOSE command from a radio transmitter if the 

safety beam is blocked.

6

 

To reconnect the operator, flip the release lever up. 

Raise the door manually until the operator reconnects.

 

NOTE:

 If the door remains idle for 5 minutes, the 

beam light will turn off to save power. The beam 

power turns on for 5 minutes when door moves down 

to the fully closed position. The beam power can be 

restored for 5 minutes by pressing the light button. 

12  Remote Controls

The operator is supplied with a three-button remote control (the second and third buttons can be used to control 

an additional operators). Additional single and multi-button remote controls can be purchased. The short wire 

on the back of the operator serves as an antenna for the remote controls. Do not cut off the wire or the remote 

controls will not operate well.

To Add or Remove a Remote Control

1

 

Press the opener’s LEARN button until the opener’s 

RED LED flashes once and the light turns on. 

remote must be added or removed while the light 

is still on (15 seconds).

2  Press and hold the desired remote button on the 

remote. The opener’s light and the RED LED will flash 

once if a remote was added.

3  Repeat Steps 1 & 2 for any additional remote controls.

To Remove A Remote Control

1

 

If a remote is already programmed to the opener and 

you want to delete it, follow the same procedure as 

ADDING REMOTES above. The opener will recognize 

the remote and delete it from memory. The RED LED 

and LIGHT will blink 4 times to show the REMOTE 

was successfully deleted.

To Remove All Remote Controls

1

 

Press and hold the operator’s LEARN button for ten 

(10) seconds or more, then release the LEARN button.

2 The RED LED and the operator’s light will flash 4 

times indicating ALL remotes have been remove from 

memory. 

Testing The Remote

1

 

Before testing the remote control, straighten out the 

operator’s antenna wire so it points up.

Stand clear of the door,

 press the remote control’s 

button and verify that the operator starts. 

PRESS THE 

REMOTE CONTROL’S BUTTON AGAIN TO STOP THE 

DOOR MID-TRAVEL.

Replacing a Remote Control’s Battery

When the blue light on the remote glows dimly, or fails 

to light at all when the remote is activated, the battery 

needs replacing.

1

 

Open the remote’s case and remove the circuit board.

2  Replace old battery with a Type CR2032 battery.
3  Re-assemble the remote.

13  Adjusting the Open and Close Limits

The limit settings control how far the door will open and close. Set the limits so the door opens just short of any 

door stops, and closes at the floor level. 

Out of the box, the operator is preset on its close limit and the 

open limit is preset for a typical 7-foot high door.

Use the wall station or a transmitter to test operate the 

door. If required, use the following steps to adjust the 

limits. 

Adjusting the Open Limit

1  Use the wall station or a remote control to move the 

door to the open limit position.

2  On the back of the opener, press both the UP and 

LEARN buttons for three seconds. The green indicator 

and opener’s light will flash twice then stay on.

3  Use the UP and DOWN buttons to jog the door at slow 

speed to fine-tune the open limit position.

4  When the door is at the proper open limit position, 

press the LEARN button to store the setting and exit 

setup. The green indicator and the opener’s light will 

flash two times. 

Adjusting the Close Limit

1  Use the wall station or a remote control to move the 

door to the close limit position.

2  On the back of the opener, press both the DOWN and 

LEARN buttons for three seconds. The RED LED and 

opener’s light will flash twice then stay on.

3  Use the UP and DOWN buttons to move the door at 

slow speed to fine-tune the close limit position.

4  When the door is at the proper close limit position, 

press the LEARN button to store the setting and exit 

setup. The RED LED and the opener’s light will flash 

two times.

 

NOTE:

 If the operator is field reset per Section 19, 

both the open and close limits must be adjusted and 

the automatic door force setup must be completed 

for proper operation. 

14  Automatic Door Force Setup

The operator automatically measures the door force throughout the entire travel of the door each time the operator 

cycles. The following steps are all that’s required to setup the safety reversal system.

Automatic Door Force Setup

1

 

Be sure that the trolley latch is up and the door is 

connected to the operator.

2

 

Operate the door through four complete open and 

close cycles.

15  Safety Reversal System Test

The operator determines that there is an obstruction if a higher than expected amount of force is detected during a 

door cycle. If an obstruction is encountered during a closing cycle, the operator and door will stop then fully open. 

If an obstruction is encountered during an opening cycle, the operator and door will stop.

Safety Reversal System Test

1

 

Lay a 2 x 4 board flat on the floor where it will be 

struck by the 

center

 of the door as it closes.

2

 

Verify that the door reverses when it strikes the 

board. The door 

must

 reverse within two seconds 

after striking the board.

16  Adjusting the Force Factor (Installation Option, Normally Not Used)

The operator uses the peak force measured during each of the last four complete cycles plus a “force factor” to 

calculate the maximum allowed force setting for the current door cycle. If the calculated maximum force setting 

is exceeded during the current door cycle, the operator reacts to the obstruction. As door hardware conditions 

change over time with weather and wear, the calculation of the maximum door force setting using the four cycle 

running average will compensate for the current conditions of the installation.

The door force is preset for the lowest amount of pressure on an obstacle to detect an obstruction. THE 
FACTORY SETTING IS OPTIMIZED FOR MOST INSTALLATIONS.

Changing the Force Factor Setting

As an installation option, the operator’s “force factor” 

can be adjusted to change the amount of pressure 

exerted on an obstacle before the operator reacts to the 

obstruction.

1

 

Press both the UP and DOWN buttons for three 

seconds. The red and green indicators and operator’s 

light will flash twice.

2  Use the UP or DOWN buttons to set the force factor. 

Pressing the UP button 

increases

 the force factor, 

pressing the DOWN button 

decreases

 the force 

factor.

FORCE FACTOR INDICATOR TABLE

GREEN ON

LOW FORCE FACTOR

RED & GREEN ON

MEDIUM FORCE FACTOR

RED ON

HIGH FORCE FACTOR

3 After selecting the force factor, press the LEARN 

button to store the setting and exit setup. The red and 

green indicators and the operator’s light will flash 

two times. 

(If the force factor is not set within one 

minute, the operator will return to normal operation 

at its previous force factor setting.)

4

  After changing the force factor setting, perform 

the Safety System Reversal Test.

 WARNING 

Children operating or playing with a garage door 

operator can injure themselves or others. The 

garage door could cause serious injury or death. 

Do not allow children to operate the remote 

control(s) or the wall station. A moving garage 

door could injure or kill someone under it. Activate 

the operator only when the door is clearly visible, 

free of obstructions and adjusted properly.

PRESS THE DESIRED REMOTE

BUTTON OR ENTER A CODE AND 

PRESS        BUTTON

2

PRESS THE

LEARN BUTTON

THE OPERATOR’S LIGHT AND RED LED WILL FLASH ONCE

IF THE REMOTE OR CODE WAS ADDED, AND FLASH FOUR 

TIMES IF A REMOTE OR CODE IS REMOVED

ADDING OR REMOVING A REMOTE OR KEYPAD

1

PRESS THE

LEARN BUTTON

FOR 10 SECONDS

OR MORE

PRESS THE DESIRED REMOTE

BUTTON WHILE RED LED IS ON

REMOVE ALL REMOTES

THE RED LED 

AND OPERATOR’S

LIGHT WILL BLINK 3 TIMES

SIGNALING THAT ALL REMOTES 

WERE REMOVED

1

2

TEST WITH SMALL OBSTACLE

THE DOOR MUST REVERSE
WITHIN 2-SECONDS AFTER

IMPACT WITH A 2 x 4 BOARD

2 x 4 BOARD LAID FLAT
UNDER CENTER OF DOOR

TESTING THE SAFETY REVERSAL SYSTEM

PRESS THE

LEARN BUTTON

PRESS THE DESIRED REMOTE

BUTTON WHILE RED LED IS ON

PREPARING TO ADD OR REMOVE A REMOTE

THE RED LED WILL

GLOW FOR 15 SECONDS

1

2

SAFETY BEAM INDICATORS

RED LIGHT

GREEN LIGHT

GREEN LIGHT
ON = POWER ON
OFF = POWER OFF

RED LIGHT
ON = BEAM ALIGNED, NO OBSTRUCTION
OFF = BEAM NOT ALIGNED, OR OBSTRUCTION

BLINKING = BEAM NEEDS BETTER ALIGNMENT

ADJUSTING THE BEAM

1. ADJUST THE SENDER
AND RECEIVER UNTIL
THE RED INDICATOR
LIGHTS SOLID

2. ADJUST SENDER
UP UNTIL RECEIVER'S
RED INDICATOR FLASHES

3. ADJUST SENDER DOWN
JUST UNTIL RECEIVER'S
RED INDICATOR LIGHTS SOLID

BLOCK THE BEAM

WHILE THE TRAVELER
IS MOVING DOWN

TOWARD

DOOR

TOWARD
OPERATOR

UP

DOWN

CHECKING FOR REVERSAL

TRAVELER

THE TRAVELER MUST REVERSE
WHEN THE BEAM IS INTERRUPTED

PLACE AN OBJECT 
IN BEAMS PATH

VERIFY THAT CONSTANT PRESSURE 
ON THE WALL STATION’S OPEN/CLOSE 
BUTTON WILL MAKE DOOR CLOSE

CHECKING FORCED CLOSURE FEATURE

RELEASE BUTTON BEFORE OPERATOR 
STOPS, THE DOORSHOULD RETURN TO 
THE OPEN POSITION

 WARNING 

With the door closed, disengage the trolley from 

the chain or belt during these alignment tests 

by pulling the red release handle.

 WARNING 

Serious injury or death from a closing garage 

door may result because of failure to test and 

adjust safety reverse system. Repeat this test 

monthly and adjust as needed.

1

2

3

4

5

6

USE VISOR CLIP IN 
SLOT TO OPEN CASE

REPLACING THE REMOTE CONTROL BATTERY

CARFULLY REMOVE

THE BOARD

LIFT OFF TOP 

OF CASE

REMOVE OLD 

BATTERY AND

DISPOSE OF

PROPERLY

INSERT NEW

CR2032 

BATTERY

PLUS SIDE UP

RE-ASSEMBLE 

REMOTE CONTROL

OPERATE THE DOOR THROUGH
FOUR  FULL OPEN AND CLOSE CYCLES

DOOR FORCE SETUP

4

4

 WARNING 

Always perform the Safety Reversal System Test 

after making any adjustments to the operator. 

PERFORM THE SAFETY REVERSAL SYSTEM TEST 

MONTHLY!

 

CAUTION

 

Set the open and close limits carefully. Setting the 
limits beyond the distance that the door can travel 
could cause damage to the door, the door hardware, 
or operator.

  CAUTION 

Do not cycle the operator full travel without 

the door connected. The automatic door force 

setting will adjust to the unloaded condition 

and may trip the safety system when the door 

is reconnected.

DOWN

UP

EXAMINE THE SPOT WHERE
DOOR CLOSES

ADJUSTING THE CLOSE LIMIT

DOWN

UP

EXAMINE THE SPOT WHERE
THE DOOR OPENS

ADJUSTING THE OPEN LIMIT

NOTICE: This device complies with Part 15 of the FCC Rules 

and with RSS-310 of Industry Canada (IC). Operation is 

subject to the following two conditions: (1) This device may not 

cause harmful interference, and (2) this device must accept 

any interference received, including interference that may 

cause undesired operation.

800 SERIES

Model: ????????

Canada 310

FREQ: 318MHz    MADE IN CHINA       P/N ????????

SETTING THE LIMITS:

- Press and hold EITHER the UP or DOWN button to set LIMIT.
- Press and hold LEARN button.
- Release both buttons. When the light blinks and the alarm
  beeps 2 times, the limit may be set.
- Press and hold the UP (or DOWN) button as needed to move  
 the

 

door to the desired position.

- Press and release the LEARN button. The light blinks and
  the alarm beeps 2 times to confirm setting.
Repeat the steps above to set the other limit.

CLASS 2 SUPPLY 28 VOLTS

! WARNING:

 Disconnect power before service. See 

instruction manual for proper installation.

    COM        WALL       COM       BEAM

UP

DOWN

LEARN

P/N 10014426

! WARNING:

 To reduce the risk of severe injury 

or death by entrapment, after making ANY 
adjustments to the operator, ensure that the door 
reverses on a 2X4 board laid flat. 
See instruction manual for proper adjust procedure.

ADD OR REMOVE REMOTES: 
Press 

LEARN button for 1 SEC then release. Light 

blinks and alarm beeps 1 time.
Press 

REMOTE BUTTON to add/remove.Light 

blinks and alarm beeps

 

1 TIME if ADDED, 4 TIMES 

if REMOVED

P/N ????????

P/N ????????

GREEN LED

RED LED

Any questions please call 1-800-543-4283

or visit www.gtoaccess.com