2.  Declaration  of  incorporation  of  partly  com-

pleted machinery

(Directive 2006/42/EC, Annex II-B)
The  manufacturer  Entrematic  Group  AB,  with  headquarters  in  Lodjursgatan  10,  SE-261  44 
Landskrona, Sweden, declares that the Ditec PWR50 automation for swing gates: 
-   is designed to be installed on a manual gate to form a machine pursuant to Directive 2006/42/

EC. The manufacturer of the motorised gate must declare conformity with Directive 2006/42/
EC (annex II-A) prior to initial machine start-up;

-   complies with the applicable essential safety requirements indicated in Annex I, Chapter 1 of 

the Directive 2006/42/EC;

-   complies with the Electromagnetic Compatibility Directive 2014/30/EU;
-  complies with the RED Directive 2014/53/EU;
-   the technical documentation complies with Annex VII-B of the Directive 2006/42/EC;
-   the  technical  documentation  is  managed  by  the  Technical  Office  of  Entrematic  Italy  (with 

headquarters in Largo U. Boccioni 1 – 21040 Origgio (VA) – ITALY) and is available upon request, 
sending an e-mail to [email protected] ;

-   a copy of the technical documentation will be given to competent national authorities, following 

a suitably justified request.

Landskrona, 01-07-2016   

       

       Matteo Fino 

                                                                                                                                 

              

        

        (Chairman)

2.1  Machinery Directive

Pursuant to the Machinery Directive (2006/42/EC), the installer who motorises a door or gate has 
the same obligations as the manufacturer of machinery and as such must:
-  prepare the technical data sheet which must contain the documents indicated in Annex V of the 

Machinery Directive;

  (the technical data sheet must be kept and placed at the disposal of competent national author-

ities for at least ten years from the date of manufacture of the motorised door or gate);

-    draw  up  the  EC  Declaration  of  Conformity  in  accordance  with  Annex  II-A  of  the  Machinery 

Directive and deliver it to the customer;

-  affix the EC marking on the motorised door or gate, in accordance with point 1.7.3 of Annex I of 

the Machinery Directive.

Содержание Ditec PWR50H

Страница 1: ...Ditec PWR50H HV HR Automation for swing gates translation of the original instructions www entrematic com IP2253EN Technical Manual ...

Страница 2: ...ets 30 6 3 Using the positioning template 31 6 4 Installing the gearmotor 32 6 5 Adjusting the mechanical end stops 33 6 6 Adjusting the lever limit switch 33 6 7 Electrical connections 34 7 Routine maintenance plan 35 8 Troubleshooting 35 9 Disposal 35 Operating instructions 36 General safety precautions for the user 36 Manual release instructions 37 i This symbol indicates instructions or notes ...

Страница 3: ...ns during use The safety devices photocells safety edges emergency stops etc must be installed taking into account the applicable laws and directives Good Working Methods installa tion premises system operating logic and the forces developed by the motorized gate The safety devices must protect the crushing shearing trapping and general hazardous areas of the motorised door Display the signs requi...

Страница 4: ...chnical Office of Entrematic Italy with headquarters in Largo U Boccioni 1 21040 Origgio VA ITALY and is available upon request sending an e mail to ditec entrematic com a copy of the technical documentation will be given to competent national authorities following a suitably justified request Landskrona 01 07 2016 Matteo Fino Chairman 2 1 Machinery Directive Pursuant to the Machinery Directive 2006...

Страница 5: ...ntermittence 200 cycles day max 60 consecutive cycles at 20 C Lifespan From 150 000 to 450 000 cycles based on the condi tions indicated in table 3 1 see the durability graphs of the product From 180 000 to 600 000 cycles based on the con ditions indicated in table 3 1 see the durability graphs of the product Operating temperature 20 C 55 C 35 C 55 C with NIO active Degree of protection IP44 Dimen...

Страница 6: ...simo di cicli 0 10 20 30 40 50 60 70 80 90 100 0 50 000 indice di gravosità 250 000 300 000 350 000 100 000 150 000 200 000 400 000 450 000 500 000 550 000 600 000 n massimo di cicli Tab 3 1 Tab 3 2 Two examples of the operator durability calculation are shown below The product lifespan is conditioned by the ex tent of other onerous conditions with reference to Tab 3 1 various corrective factors h...

Страница 7: ...eypad 4 Actuator without magnetic limit switches 2 x 1 5mm Actuator with magnetic limit switches 3 x 1 5mm 5 Photocells 4 x 0 5mm 6 Control panel 3G x 1 5mm A Connect the power supply to a type approved omnipolar switch not supplied with a contact opening distance of at least 3mm Connection to the mains must be via an independent channel separated from the connections to the command and safety dev...

Страница 8: ...window 9 Screw for fastening the rear cover 10 Screw for fastening the front cover 11 Front cover 12 Protective brushes 13 Mechanical close stops 14 Magnetic limit switches 15 Drive screw 16 Split nut magnet 107 100 525 1044 10 11 9 12 15 16 13 7 8 10 11 9 12 7 8 14 16 15 PWR50H HR PWR50HV Fig 5 1 Fig 5 2 ...

Страница 9: ...se the values of A and B on the basis of the required opening angle and in relation to the on site spaces and overall dimensions Increasing measurement A you reduce the opening approach speed Reducing measurement B you increase the gate opening angle Measurements A and B must however be compatible with the effective piston stroke A P D E L B C min 60 con apertura a 90 S i The automation fastening ...

Страница 10: ...7 following the indications given in Tab 6 1 Once you have fastened the rear bracket 17 following the measurements given on page 12 fasten the front bracket 18 to the gate With the gate fully closed position the front bracket 18 respecting the measurement L Make sure the front bracket 18 and rear bracket 17 are properly levelled as shown in the figures below then fasten the front bracket 18 to the ...

Страница 11: ...e correct position of the brackets and the distance between them This avoids positioning errors and incorrect fixing hole alignment thanks also to the built in spirit level The installation template is compatible with all the pistons of the PWR Obbi and Luxo ranges 6 3 Using the positioning template 80 60 115 90 Ø9 6 185 15 170 10 Ø14 S 17 E 18 140 20 50 10 42 120 Ø22 80 60 115 90 Ø9 6 50 ...

Страница 12: ...g manually and insert the front coupling pin 25 in the hole of the front fas tening bracket 18 Lock the pin in the bracket using the washer Ø30mm 26 and nut M16 27 supplied Before installing the piston grease the rotation points NB pay special attention to the correct positioning of the washer on the brackets Insert the protective brushes 12 in the relative guides on the front cover 11 and push th...

Страница 13: ... end stops with a 4mm Allen wrench just enough so that they can slide along the drive screw then move them up against the split nut and fix them in place Bring the gate wing to its fully open or closed position Loosen the limit switches with a Phillips screwdriver just enough so that they can slide along the guide then bring them above the split nut 16 until the magnetic sensor is activated Fix the...

Страница 14: ...am in Fig 6 4 Fasten the rear cover 7 to the gearmotor The electrical connections and start up of the PWR50H HR HV gearmotors are explained in the installation manuals of the LCU40H control panels To increase the protection of the motor cable a corrugated flexible tube can be used Fig 6 2 Fig 6 3 Fig 6 4 L N 33 32 31 36 35 34 Alimentazione 230V 50 60 Hz 24V 24V Motoriduttore 24V con ritardo in aper...

Страница 15: ...out for recycling Refer to the local disposal regulations before proceeding The packaging materials must not be discarded in the environment or left within reach of chil dren as they are a potential source of danger To dispose of electrical and electronic equipment batteries and accumulators correctly take the product to the differentiated disposal and recycling centres respecting the regulations ...

Страница 16: ...te as this may cause a dangerous situation The motorised door or gate may be used by children over the age of 8 and by people with reduced physical sensorial or mental abilities or lack of experience or knowledge as long as they are properly supervised or have been instructed in the safe use of the device and the relative hazards Children must be supervised to make sure they do not play with the d...

Страница 17: ... cannot be held responsible in any way for damage caused by any possible mistakes or omissions We reserve the right to make changes without prior notice Copying scanning or changing in any way is expressly forbidden unless authorised in writing by Entrematic Group AB 8 they are supervised To ensure that the system works efficiently and correctly the manufactur er s indications must be complied with...

Страница 18: ...IP2253EN 2017 08 21 Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www entrematic com ...

Отзывы: