background image

Ditec EL31R

Installation Manual for control panel for 24V

 

 automations with 

built-in radio.

www.ditecentrematic.com

IP1851EN

POWER

SA

11

IN

Limit switch

Limit switch

Acce

ssories outpu

t

12

VA

A

VC TC R1

AUX

A

N

T

B

A

T

SAFETY

24V~

1 5 9 13 20

0 1 6 8 41

C NO

11

12

0

14 0

PRG

COM

ENC

JR1

1

ON

2 3 4 5 6

B

1

ON

2 3 4 5 6 7 8

EL31R

SIG

-M

+M

Power supply

Step-by-ste

p

Sa

fe

ty sto

p

Sa

fe

ty r

eopening

Stop

Saf

ety test

Flashing light

Gate open indicator light

Partial opening

GOL4

F1

Transformer

Safety switch

24V=             

Motor

BATK3

Содержание Ditec EL31R

Страница 1: ...t switch Accessories output 12 VA A VC TC R1 AUX A N T B A T SAFETY 24V 1 5 9 13 20 0 1 6 8 41 C NO 11 12 0 14 0 PRG COM ENC JR1 1 ON 2 3 4 5 6 B 1 ON 2 3 4 5 6 7 8 EL31R SIG M M Power supply Step by step Safety stop Safety reopening Stop Safety test Flashing light Gate open indicator light Partial opening GOL4 F1 Transformer Safety switch 24V Motor BATK3 ...

Страница 2: ...28 IP1851EN 2014 09 30 ...

Страница 3: ...rs dip switches 38 7 4 Jumper 39 7 5 Signals 39 8 Radio 40 9 Working modes for sliding gates 41 10 Start up 42 10 1 Sliding gates start up 42 10 2 Barriers start up 43 11 Troubleshooting 44 12 Application example for sliding gates 46 13 Application example for barriers 47 14 Example of operator present function mode 47 15 Application example for parallel automations 48 Key i This symbol indicates ...

Страница 4: ... in the mains supply Check that upstream of the electrical installation there is an adequate residual current circuit breaker and a suitable overcurrent cutout When requested connect the automation to an effective earthing system that complies with current safety standards During installation maintenance and repair operations cut off the power supply before opening the cover to access the electric...

Страница 5: ...3 3M1CR5 3M1CR5C5 3M1CR7 3M1CR7C5 3M1QK 3M1QKC7 Power supply 230 V 50 60 Hz 230 V 50 60 Hz 230 V 50 60 Hz 230 V 50 60 Hz F1 fuse F1 6A F1 6A F2A F1 6A Motor output 24 V 8 A 24 V 9 5 A 24 V 14 A 24 V 7 A Accessories power supply 24 V 0 3 A 24 V 0 3 A 24 V 0 3 A 24 V 0 3 A Temperature min 20 C max 55 C min 20 C max 55 C min 20 C max 55 C min 20 C max 55 C Degree of protection IP24D IP24D IP24D IP24D...

Страница 6: ...pening the safety contact triggers a reversal of the movement reopening during the closing operation 1 9 N C STOP Opening the safety contact stops the current operation 1 9 N O OPERATOR PRESENT CONTROL Opening of contact 1 9 enables the operator present function opening with operator present 1 5 with DIP1A ON and TC MAX closing with operator present 1 6 with DIP2B OFF N B any safety devices automa...

Страница 7: ...l in series with the photocell output contact if installed WARNING if not used make a jumper for ter minals 41 6 1 8 N C REVERSE SAFETY CONTACT Connect the output contact of the device to termi nals 1 8 on the control panel in series with the photocell output contact if installed WARNING if not used make a jumper for ter minals 41 8 Command Function Description PRG N O TRANSMITTER STORAGE AND CANC...

Страница 8: ...s re establish or until the battery voltage drops below the safety threshold The panel turns off in the last case WARNING the batteries must always be connected to the control panel for charging Periodically check the efficiency of the batteries N B the operating temperature of the rechargeable batteries is approximately 5 C 40 C 1 5 9 13 20 24 V 3 W Automation status light proportional The light ...

Страница 9: ...is off the panel is powered by the batteries until the power is re establish or until the battery voltage drops below the safety threshold The panel turns off in the last case WARNING the batteries must always be connected to the control panel for charging Periodically check the efficiency of the batteries N B the operating temperature of the rechargeable batteries is approximately 5 C 40 C 1 5 9 ...

Страница 10: ...once contact 1 9 has closed again automatic closing is only enabled after a total partial or step by step opening command TC MIN 0 s MAX 120 s With DIP3B OFF permanent closing of contact 1 20 enables automatic clos ing CROSS R1 min max Power setting The control panel is equipped with a safety device that stops motion if an obstacle is encountered during the opening operation and reverses motion du...

Страница 11: ...oth opening and closing DIP6A Safety test terminal 41 Disabled Enabled DIP B Description OFF ON DIP1B Reversal safety contact opera tion With automation stopped and contact 1 8 open opening op erations are permitted With automation stopped and 1 8 open all operations are disabled DIP2B Command functions 1 6 Closing Stop DIP3B Command functions 1 20 Automatic closing on Partial opening command DIP4...

Страница 12: ...tic closing with TC 3 s DIP6A Safety test terminal 41 Disabled Enabled DIP B Description OFF ON DIP1B Reversal safety contact opera tion With automation stopped and contact 1 8 open opening op erations are permitted With automation stopped and 1 8 open all operations are disabled DIP2B Command functions 1 6 Closing Stop DIP3B Preflashing for 3 seconds After intervention of safety switch 1 8 and wi...

Страница 13: ... status of a dip switch SA At least one of the safety contacts is open 1 9 contact is open DIP6A selection is not consistent with the con nection of terminals 6 8 Safety test failure terminal 41 Operations count performed only when control panel is switched on 1000 operations 10000 operations 11 0 11 limit switch contact is open 12 0 12 limit switch contact is open SIG Transmitter enabling storage...

Страница 14: ...edure 10 seconds after the last transmission or you can press the PRG key again the SIG LED goes off Up to four CH keys of a single remote control can be stored If only one any CH key of the remote control is stored command 1 5 step by step opening is carried out If 2 4 CH keys of a single remote control are stored the functions matched with the CH keys are as follows CH1 command 1 5 step by step ...

Страница 15: ...th encoder DIP5B ON by selecting DIP6B ON the control panel activates an innovative automatic detection system for the current necessary to move the automation at any point of the opening and closing operation The current stored profile shows the forces necessary for correct movement taking the frictions into consideration The current profile is automatically updated every time an operation is com...

Страница 16: ...ing and closing commands Check that the limit switches are activated if used 7 Connect the safety devices removing the relative jumpers and check they function cor rectly 8 If desired adjust the automatic closing time with the TC trimmer WARNING the automatic closing time after a safety device has triggered depends on the DIP3A setting 9 Set the desired opening and closing speed with the VA and VC...

Страница 17: ...desired opening direction with DIP2A Set DIP4B OFF and DIP6B OFF 5 Manually move the barrier bar and make sure it is correctly balanced 6 Switch on and check the automation is operating correctly with the subsequent opening and closing commands Check that the limit switches are activated if used 7 Connect the safety devices removing the relative jumpers and check they function correctly 8 If desir...

Страница 18: ...orage module The remote control does not work Check the correct memorisation of the transmitters on the built in radio If there is a fault with the radio receiver that is built into the control panel the remote control codes can be read by removing the storage module Photocells activated SA LED on Check that the photocells are clean and operating correctly The automatic closing does not work Check...

Страница 19: ...remote control has lim ited range and does not work with the automation moving The radio transmission is impeded by metal structures and reinforced concrete walls Install the antenna outside Substitute the transmitter batter ies ...

Страница 20: ...P6B OFF Example 2 The remote control can be used with step by step functioning and at the same time terminal 5 with opening function by making the connections indicated and setting DIP1A OFF Closing limit switch Opening limit switch 1 5 9 13 20 0 1 6 8 41 C NO 11 12 0 14 0 VA VC TC R1 MAX A 1 ON 2 3 4 5 6 B 1 ON 2 3 4 5 6 7 DIP2B ON DIP1A ON Closing limit switch Opening limit switch Opening Partia...

Страница 21: ...TC R1 MAX 50 50 A 1 ON 2 3 4 5 6 B 1 ON 2 3 4 5 6 7 8 DIP2B OFF DIP1A ON Closing limit switch Opening limit switch 1 5 9 13 20 0 1 6 8 41 C NO 11 12 0 14 0 VA VC TC R1 MAX A 1 ON 2 3 4 5 6 B 1 ON 2 3 4 5 6 7 DIP2B ON DIP5B ON DIP1A ON 14 Operator present function modes Quando il quadro elettronico viene usato in modalità uomo presente scollegare il morsetto 9 impostare il senso di marcia mediante ...

Страница 22: ...se the radio receivers on the control panels JR1 OFF but insert a BIXLR22 radio receiver Adjust TC VA and VC trimmers in the same position on both control panels i N B the opening and closing movements may not be synchronised JR1 JR1 A B BIXLR22 ANT OUT2 1 2 3 4 1 2 3 4 JR1 JR2 1 5 9 13 20 0 1 6 8 41 1 5 9 13 20 0 1 6 8 41 A 1 ON 2 3 4 5 6 B 1 ON 2 3 4 5 6 7 DIP1A ON DIP2A ON DIP1A ON A 1 ON 2 3 4...

Страница 23: ...cation have been drawn up with the greatest care Entrematic Group AB cannot be held responsible in any way for any damage caused by mistakes or omissions in this publica tion We reserve the right to make changes without prior notice Copying scanning and changing in any way are expressly forbidden unless authorised in writing by Entrematic Group AB ...