5.2.2.2
Modem to Controller
To make the connection between the master controller and the host computer you will use two cables: one between the
host computer and its modem (see Section 5.2.3 on page 24), and one between the master controller and its modem.
•
If the modem has a female DB-25 connector, you must use a Keri Systems KDP-336 cable or create a cable as
shown in Figure 23 or Figure 24.
•
If the modem has a female DB-9 connector, you must create a cable as shown in Figure 25 or Figure 26 on page 22.
•
If the modem was purchased from Keri Systems, it comes with an adapter that accommodates a female DB-9
connector (should the modem have a DB-9 instead of a DB-25 connector). Use this adapter cable in conjunction
with a KDP-336 cable to make the modem/controller connection. See Figure 27 on page 23.
The Keri Systems part number for this cable is KDP-336.
Figure 23: Modem/DB-25M to Telephone Entry/DB-9M Serial Port Connection
Figure 24: Modem/DB-25M to Telephone Entry/TB-12 Serial Port Connection