background image

CONTROL SOLUTION

1

1

2

2

3

4

5

6

7

8

9

10

PROPER TESTING TECHNIQUE

WASH AND 

DRY HANDS

ALCOHOL SWAB

DON’T SQUEEZE

CONFIRM CODE

WHEN TO USE 

CONTROL SOLUTION

WHEN TO RUN A CONTROL TEST

CONTROL TEST PROCEDURE

My

Gluco

Health

 TEST STRIPS

PROTECT YOUR SUPPLIES

ALWAYS USE A NEW,

STERILE LANCET

DISCARD FIRST DROP

FINGER TESTING

The single most 
important step you can take to get an 
accurate reading is to wash and dry your 
hands before you prick your 

fi

 nger. Make 

sure there is no food residue, lotion, oil, 
or other contaminants on your hands. 
This will effect results.

Squeezing your 

fi

 nger may 

effect the blood sample by 
causing more interstitial 

fl

 uid 

to enter the sample than capil-
lary blood. Washing with warm 
water will increase blood 

fl

 ow 

to 

fi

 ngers, making it easier to 

get blood without pressure.

•  If  you  get  a  reading  that  seems                
  incorrect
• Before adjusting medication
• When a blood glucose test result is  
  too high or too low
• If you feel the meter or test strips  
  have been compromised in any        
  way
• Remember to select the Control  
  Solution Icon when performing a   
  control test.

When using a test strip, insert 
it into the meter and con

fi

 rm 

the strip code on the meter is 
the same as the strip code on 
the bottle. Never use damaged 
or expired test strips.

Accurate results depend upon 
carefully following all product 
use instructions.

The meter will auto-
matically turn on and 
display the code num-
ber. Make sure the 
code number matches 
the code number on 
the test strip vial.

Place a drop of solution on a clean, dry 
surface (for example: the lid of your test 
strip vial). Pick up the meter and touch 
the end of the test strip to the drop. 
Make sure to hold the test strip to the 
drop until the beep sounds.

Compare the control 
reading with the range 
printed on the test strip 
vial. If the reading is not 
within the range, repeat 
test. If the second reading 
is not within the range, 
contact Entra Health 
Systems. 

Prior to use, shake 
the control solution 

bottle vigorously.

A test result will appear 

in 3 seconds. 

Always discard 

fi

 rst drop of control 

solution.

Wipe the tip 

clean. 

Make sure the test 

strip is inserted 

fully into the test 

slot of the meter.

1. If you get a reading that 
seems incorrect
2. Before adjusting medication

Lancets are for single 
use only.

If you do not have access to a 
sink when you are testing, rubbing 
 alcohol will do. Use it in place of 
hand washing to clean the testing 
area or 

fi

 nger to remove any resi-

due before you test. Make sure the 
area is dry before testing.

It is recommended that the meter, 
control solution and test strips be 
at room temperature before testing. 
Make sure the control solution bottle 
is tightly closed and stored between 
46 - 86°F (2–30° C). Use before the 
expiration date shown on the bottle. 
Use within 3 months of 

fi

 rst opening. 

Make sure to discard after 3 months.

Using the correct strips and 
storing them properly is im-
portant. Only MyGlucoHealth 
test strips will work with the 
 MyGlucoHealth meter.

If there is nowhere to wash 
your hands, and you’ve 
forgotten  alcohol swabs, 
your best option: Prick your 

fi

 nger and wipe the 

fi

 rst drop 

of blood away and test with 
the second drop of blood, 
which is less likely to be 
contaminated.

Don’t store your meter, test 
strips or control solution 
where it’s too hot, too cold, 
too humid, or too high in 
altitude. Close the vial cap 
tightly, immediately after 
removing the MyGlucoHealth 
Test Strip. Improperly stored 
strips will yield poor results.

Use 

fi

 ngertip for 

 most accurate 
 testing.

®

HOT

COLD

HUMID

HIGH

ALTITUDE

NEW

USED

1

7

6

2

8

9

3

4

5

1

2

3