Enthermics ivNow Series Скачать руководство пользователя страница 9

MN-28929 (REV. 4) 06/15 • IVNOW MANUAL • 7

ivNow DIMENSIONS

Note: 

Individual ivNow units cannot be stacked in the fi eld. 

Multiple cavity units are available from the factory in the 
confi gurations below. Three-liter bag capacity available on 
ivNow-1, ivNow-2, & ivNow-3 with an additional adapter. 

ivNow-1

 

(one (1) bag capacity) can be placed directly on 

a countertop, mounted on a mobile equipment pole stand, 
mounted on a wall using brackets, or mounted to a three-liter 
bag tilt kit*.

ivNow-2 

(two (2) bag capacity) can be placed directly on 

a countertop, mounted on a wall using mounting brackets, or 
mounted to a three-liter bag tilt kit*.

ivNow-3 

(three (3) bag capacity) must be mounted on a heavy 

duty mobile equipment pole stand, on a wall using mounting 
brackets, or mounted to a three-liter bag tilt kit*.

ivNow-4 

(four (4) bag capacity) must be mounted on a wall 

using mounting brackets*.

ivNow-5

 (fi ve (5) bag capacity) must be mounted on a wall using 

mounting brackets*.

ivNow-6 

(six (6) bag capacity) must be mounted on a wall using 

mounting brackets*.

*Mounting hardware sold separately.

Cord exits bottom 
of wall mounted units

14.5" (368.7mm)

CORD LENGTH

44" (1118mm)

35" (890.1mm)

cord out botto

m

Wall-mounted Unit 
6.74" (171.2mm)

Countertop Unit

7.8" (197.7mm)**

** maintain a minimum of 4" (102mm) 
    clearance for bending of cord.

29.6" (752.7mm)

cord out botto

m

CORD LENGTH

50" (1270mm)

14.5" (368.7mm)

24.2" (615.3mm)

cord out botto

m

CORD LENGTH

55" (1397mm)

14.5" (368.7mm)

7.2" (182.1mm)

8.0" (203.1mm)

CORD LENGTH

72" (1829mm)

14.5" (368.7mm)

12.6" (318.9mm)

13.4" (340.5mm)

CORD LENGTH

66" (1676mm)

14.5" (368.7mm)

18.0" (456.9mm)

18.9" (478.8mm)

CORD LENGTH

61" (1549mm)

14.5" (368.7mm)

ivNow-6

ivNow-5

ivNow-4

ivNow-3

ivNow-2

ivNow-1

Note:  

• Countertop unit (1 or 2 cavity), power cord exits back of unit.

• Wall mounted units (up to 6 cavities), power cord exits bottom 

of unit (shown below).

• Mobile equipment pole mounted unit (up to 3 cavities), power 

cord exits bottom.

• Countertop or wall mounted units (up to 3 cavities) with 

three-liter bag tilt kit, power cord exits back.

Cord position is interchangeable, instructions available through service.

ivNow CONFIGURATIONS

Содержание ivNow Series

Страница 1: ...alinfo enthermics com www enthermics com P R I N T E D I N U S A SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE MADE IN THE U S A Operation and Care Manual MN 28929 Rev 4 06 15 p r i n t e d i n u s a ivNow 1 ivNow 2 ivNow 3 ivNow 4 ivNow 5 ivNow 6 ivNow 120V 230V ivNow 1 countertop module ivNow 3 with 3L Bag Tilt kit countertop module ivNow 6 with Vertical Wall Mount Bracket Kit ...

Страница 2: ...Configurations 7 Options Accessories 8 Operating Instructions Control Features 9 Installation 10 Operation Procedures 11 Care and Cleaning 12 Troubleshooting Guide 13 Service Parts Lists and Drawings 14 Wire Diagrams Always refer to the wire diagram s included with the unit for most current version MN 28929 REV 4 05 15 IVNOW MANUAL Authorized Representative MDSS GmbH Schiffgraben 41 30175 Hannover...

Страница 3: ... 24 hours is recommended Recommended environmental temperature range is 15 C to 32 C 60 F to 90 F Recommended relative humidity is above 20 non condensation E N V I R O N M E N T A L C O N D I T I O N S All Enthermics Medical Systems equipment is sold F O B shipping point and when accepted by the carrier such shipments become the property of the consignee Should damage occur in shipment it is a ma...

Страница 4: ...efully before initiating the installation of this appliance DO NOT DISCARD THIS MANUAL This manual is considered to be part of the appliance and is to be provided to the owner or manager of the business or to the person responsible for training operators Additional manuals are available from the service department 3 Remove all protective plastic film packaging materials and accessories from the app...

Страница 5: ...ymbol is ignored NOT ICE For equipment delivered for use in any location regulated by the following directive DO NOT dispose of electrical or electronic equipment with other municipal waste 1 Fluid warmers are ONLY intended for warming medical solutions for irrigation and injection prior to their use Please refer to the labeling of the manufacturer of the products to be warmed regarding the recomm...

Страница 6: ...lied Parts Mode of Operation Continuous NEMA 5 15P 15A 125V Plug Hospital Grade ivNow 3 POWER REQUIREMENTS 120 V A C 60 Hz 1 ph 0 45 kW 3 8 Amps Safety Class I Equipment No Applied Parts Mode of Operation Continuous NEMA 5 15P 15A 125V Plug Hospital Grade ivNow 4 POWER REQUIREMENTS 120 V A C 60 Hz 1 ph 0 6 kW 5 0 Amps Safety Class I Equipment No Applied Parts Mode of Operation Continuous NEMA 5 15...

Страница 7: ...50 60 Hz 1 ph 0 6 kW 2 6 Amps Type B Equipment BS 1363 Plug UK only CEE 7 7 220 230V Plug ivNow 5 POWER REQUIREMENTS 230 V A C 50 60 Hz 1 ph 0 75 kW 3 2 Amps Type B Equipment BS 1363 Plug UK only CEE 7 7 220 230V Plug ivNow 6 POWER REQUIREMENTS 230 V A C 50 60 Hz 1 ph 0 9 kW 3 9 Amps Type B Equipment BS 1363 Plug UK only CEE 7 7 220 230V Plug Other international plugs are available contact factory...

Страница 8: ...rature beginning when the bag reaches set point temperature A status button will display the time the fluid has been held at temperature NOTE In the event that fluid should spill inside the module unplug the unit to prevent an electrical shock hazard Wipe excess fluid from module immediately Refer to qualified service personnel Qualified service personnel should remove the module control and remov...

Страница 9: ...nting brackets ivNow 6 six 6 bag capacity must be mounted on a wall using mounting brackets Mounting hardware sold separately Cord exits bottom of wall mounted units 14 5 368 7mm CORD LENGTH 44 1118mm 35 890 1mm cord out bottom Wall mounted Unit 6 74 171 2mm Countertop Unit 7 8 197 7mm maintain a minimum of 4 102mm clearance for bending of cord 29 6 752 7mm cord out bottom CORD LENGTH 50 1270mm 14...

Страница 10: ...and mount to equipment stand or mast stand not included cord exits bottom of unit 5012735 Bracket Kit for Horizontal Wall Mount two 2 GCX horizontal rails included 5012242 two 2 GCX horizontal rails included 5012242 two 2 GCX horizontal rails included 5012242 cord exits bottom of unit two 2 GCX horizontal rails included 5012242 Bracket Kit for Seismic Horizontal Wall Mount OPA 0698 10 one 1 GCX ho...

Страница 11: ...w the set point Do not use fluid bag until display stops flashing During normal operation the actual temperature is shown on the display In the event of an error the display will show the error code and the error must be cleared by the user See the Troubleshooting section of this manual for instructions STATUS INDICATOR LIGHT The green STATUS INDICATOR will illuminate when the bag reaches set temp...

Страница 12: ...r ivNow 3 can be wall mounted with the three liter bag tilt stand Figure 2 All units can be wall mounted using wall mount hardware Figure 3 A single unit ivNow 1 can also be mounted on a mobile equipment pole NOTE Individual ivNow units cannot be stacked Units with multiple stacked module configurations are available from the factory only See the separate instructions provided with your mobile equ...

Страница 13: ... with 21ºC 70ºF ambient temperature 4 The display will continue to show the current bag temperature as it heats the fluid 5 The green status indicator will illuminate when the bag is within 0 2 C 0 3 F of the set point temperature 6 Press and hold STATUS key for 2 seconds to see how long the fluid has been at set temperature See Control Panel Key Status Key on previous page for more instructions C...

Страница 14: ...the module control and remove any remaining liquid Perform necessary hospital electrical safety checks before returning the unit to operation ANNUAL PREVENTATIVE MAINTENANCE 1 Ensure that the correct Operation and Care Manual is available to all users 2 Ensure that all users have been properly trained in unit s operation 3 Do not exceed the unit s capacity 4 Inspect condition of plug and cord Repl...

Страница 15: ... lower control assembly should be replaced by a qualified service technician Contact Service E 50 Analog to Digital Convertor Error Press Status Key to clear error code Remove fluid bag and allow unit to cool down Inspect fluid and discard if necessary If error persists after cool down and reset the lower control assembly should be replaced by a qualified service technician Contact Service E FO Flas...

Страница 16: ...SEMBLY 1 5008986 12 KIT SWITCH 1 5018369 13 SCREW M3 x 0 05 x 8mm PAN 2 SC 29333 14 BRACKET PLATE SENSOR 1 1016799 15 TOP COVER 1 CV 28578 16 RESET BUTTON 1 CV 29140 17 CONTROL PANEL ASSY 1 5008987 17A CONTROL PANEL ASSY NO LOGO 1 5012152 17B CONTROL PANEL ASSY 230V 1 5012347 17C CONTROL PANEL ASSY NO LOGO 230V 1 5012348 18 M4 x 6mm PH PAN HD M S 18 8 2 SC 22273 19 BRACKET ASSY STRAIN RELIEF 1 501...

Страница 17: ...nclude both model and serial numbers in your correspondence regarding the unit Model _____________________________________ Serial Number _____________________________________ SERIAL NUMBER IS REQUIRED FOR ALL INQUIRIES i v N o w F L U I D W A R M I N G M O D U L E 1 1A 2 4 3 5 6 7 8 9 15 11 10 12 13 14 16 17 17A 17B 17C 18 ...

Страница 18: ...th model and serial numbers in your correspondence regarding the unit Model _____________________________________ Serial Number _____________________________________ SERIAL NUMBER IS REQUIRED FOR ALL INQUIRIES i v N o w F L U I D W A R M I N G M O D U L E c o n t i n u e d 20 8 19 4 21 21A 21B 21C 21D 21E 22 5 23 24 25 26 27 28 29 ...

Страница 19: ...MN 28929 REV 4 06 15 IVNOW MANUAL 17 ivNow 1 120V Wiring Diagram ...

Страница 20: ...MN 28929 REV 4 06 15 IVNOW MANUAL 18 ivNow 2 120V Wiring Diagram ...

Страница 21: ...MN 28929 REV 4 06 15 IVNOW MANUAL 19 ivNow 3 120V Wiring Diagram ...

Страница 22: ...MN 28929 REV 4 06 15 IVNOW MANUAL 20 ivNow 4 120V Wiring Diagram ...

Страница 23: ...MN 28929 REV 4 06 15 IVNOW MANUAL 21 ivNow 5 120V Wiring Diagram ...

Страница 24: ...MN 28929 REV 4 06 15 IVNOW MANUAL 22 ivNow 6 120V Wiring Diagram ...

Страница 25: ...MN 28929 REV 4 06 15 IVNOW MANUAL 23 ivNow 1 230V Wiring Diagram ...

Страница 26: ...MN 28929 REV 4 06 15 IVNOW MANUAL 24 ivNow 2 230V Wiring Diagram ...

Страница 27: ...MN 28929 REV 4 06 15 IVNOW MANUAL 25 ivNow 3 230V Wiring Diagram ...

Страница 28: ...MN 28929 REV 4 06 15 IVNOW MANUAL 26 ivNow 4 230V Wiring Diagram ...

Страница 29: ...MN 28929 REV 4 06 15 IVNOW MANUAL 27 ivNow 5 230V Wiring Diagram ...

Страница 30: ...MN 28929 REV 4 06 15 IVNOW MANUAL 28 ivNow 6 230V Wiring Diagram ...

Страница 31: ...any PO Box 443 Menomonee Falls WI 53052 0443 W164 N9221 Water St Menomonee Falls WI 53051 Tel 262 251 8356 800 TO B WARM generalinfo enthermics com www enthermics com P R I N T E D I N U S A SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE MADE IN THE U S A ...

Отзывы: