55
7.2.4Energy
7.2.4Energy
7.2.5Min&Max Values
Parameter Unit
Description
Range
Sensitivity
Max. Value
V1, V2, V3 V
Phase-Neutral Rms Voltage 10 – 400 Vac
±0.5%
1MV
U1, U2, U3 V
Phase-Phase Rms Voltage 10 – 690 Vac
±0.5%
1.71 MV
I1, I2, I3
A
Phase Current
0.005 - 6A
±0.5%
10 kA
P1, P2, P3 W
Phase Active Power
-2400 – 2400W
± 1%
-10GW - 10GW
∑P
W
Total Active Power
-7200 – 7200W
± 1%
-30GW - 30GW
Q1, Q2, Q3 VAr
Phase Reactive Power
2400 – 2400 VAr
± 1%
-10GVAr
-10GVAr
∑Q Ind.
VAr
Total Inductive Reactive
Power
0.1 – 7200 VAr
± 1%
30GVAr
∑Q
VAr
Total Reactive Power
-7200 – 7200 VAr ± 1%
-30GVAr -
30GVAr
S1, S2, S3 W
Phase Apparent Power
-2400 – 2400W
± 1%
-10GW - 10GW
∑S
W
Total Apparent Power
-7200 – 7200W
± 1%
-30GW - 30GW
Parameter Unit
Description
Range
Sensitivity
Max. Value
+Ea
Wh
Imp Active Energy
0 – 2^64
± 1%
2^64 Wh
+Er
VArh Imp Reactive Energy
0 – 2^64
± 1%
2^64 VArh
-Er
VArh Exp Reactive Energy
0 – 2^64
± 1%
2^64 VArh
ES
VAh
Apparent Power
0 – 2^64
± 1%
2^64 VAh
Esg
VAh
Generator Apparent Energy 0 – 2^64
± 1%
2^64 Vah
7.2.5Min&Max Values