VERTICAL HORIZON FAST ETHERNET SWITCH

STACKING MODULE

Enterasys’s VH-STACK Stacking Module can be used
to stack up to four VH-2402S switch units. Running at
a bandwidth of over 4 Gbps, these modules provide a
common interface to the attached switches, allowing
the stack to function and be managed as a single
device.

System and Port Status LEDs

LEDs are provided on the front panel of the switch.
These LEDs can be used to verify if the stack is
functioning properly. The following table details the
indicator functions provided by the VH-2402S:

Port and System Status LEDs

LED

Condition

Status

Power

On

Switch is receiving power.

RDP

On

Redundant power is on, and in
backup or active mode.

Off

Redundant power is off or has failed.

Mgmt

On

Agent is operational.

RJ-45 Ports

Link

On

Port has established a valid network
connection

Yellow

Valid 10 Mbps connection.

Green

Valid 100 Mbps connection.

Flashing

Port has been partitioned due to an
abnormal network condition, or
manually disabled.

Activity

1

On

Traffic is passing through the port.

FDX

1

On

Port has been set to full duplex.

FC

1

On

Flow control enabled.

Module Ports

Status

On

A module is installed in this slot.

Activity

Flashing

Traffic is passing through the port

1: Use the Mode Select button to select LED display mode.

2: There is no LED for indicating stacking status.

INSTALLING THE MODULE

CAUTION:

 The VH-STACK Stacking Module is

designed for VH-2402S switches only. Do not try to
install these modules in any other units.

The VH-STACK Stacking Module installs in the lower-
left slot on the rear panel of the VH-2402S switch. Do
not install this module in any other slot. To install the
module, follow the instructions below.

Equipment Checklist

After unpacking the Stacking Module, check the
contents of the box to be sure you’ve received the
following items:

One VH-STACK Stacking Module

One Stacking Cable

This document

Handling the Module

CAUTION:

  The VH-STACK Stacking Module can

easily be damaged by electrostatic discharge.

To prevent electrostatic damage, observe the following
guidelines:

Do not remove the module from its packaging until
you are ready to install it.

Do not touch any of the module’s pins, connectors
or components.

Hold the module only by its edges or front panel.

Wear an anti-static wristband connected to a
suitable earth ground whenever handling the
module.

Store or transport this module only in appropriate
anti-static packaging.

Instructions

CAUTION:

 The switch must be powered off before

installing or replacing any module.

1.

Power off the switch:

 Disconnect the AC power

cord from the switch. If a redundant power unit
(RPU) is present, disconnect its DC cable
connection to the switch.

2.

Remove network cables:

 If you are replacing a

module, remove the cable attached to the port on
the module.

3.

Loosen the screws on the installed module or
slot faceplate:

 Using your fingers or a flathead

screwdriver, turn the screws securing the module
(or faceplate) in the lower-left slot in a counter-
clockwise direction until they are free of the
chassis. Be sure not to completely remove the
screws from the module or faceplate.

4.

Remove the installed module or faceplate:

Firmly pull on the screws until the module is free of
the switch. Carefully slide the module straight out of
the slot.

Keep the original faceplate for future use. If you
should remove the module, replace the faceplate to
prevent dust and debris from entering the unit and
to maintain proper air flow.

5.

Insert the new module into the switch: 

Holding

the new module with the text on the front panel
upright, carefully slide the module into the switch
slot and press gently until it snaps into place. Be
sure the new module’s front panel is flush with the
switch panel.

6.

Secure the new module: 

Secure the new module

in place by screwing the attached screws clockwise
into the switch’s chassis. Tighten them enough to
secure the module, but not so tight as to prevent
them from being unscrewed by hand.

7.

Connect the stack cables: 

Attach one end of the

stacking cable to the stack connector labeled
“DOWN” on the top device, and the other end to
the connector labeled “UP” on the next lower
device. Repeat this step until all the devices have
been connected.

8.

Power on the switch: 

Reconnect the previously

removed power sources to the switch. (Note that
the Management Module in the bottom switch will
become the master.) The front-panel LEDs on the
switches should indicate their status. Refer to the
table of LEDs in this guide for a description of the
LED indications. If the stack is not functioning
properly, see “Troubleshooting” below.

More details concerning connection options and
network applications can be found in the
VH-2402S Installation Guide. Information on managing
the stack can be found in the Management Guide that
is included with the base unit.

TROUBLESHOOTING

If you experience any problems with the module, check
the following items before contacting Enterasys’s
Technical Support:

Ensure that all the switches in the stack are
powered up.

Ensure that the devices attached to the stack are
powered up and operating correctly.

Ensure that the Stacking Modules are properly
seated in their slots.

Check the connectors on both ends of the stack
cable to be sure they are properly engaged. Tighten
the thumb screws on the cable connectors to
ensure a good connection.