Replacing the SSA Fans
3-16 Troubleshooting
b. Remove
the
failed
fan’s
cables
from
the
rubber
grommet.
You
may
have
to
lift
the
rubber
grommet
out
of
the
chassis
to
remove
the
failed
fan’s
cables
from
the
grommet.
The
grommet
is
slit.
c.
Disconnect
the
fan
from
the
appropriate
connector.
The
bank
of
F11–F13
connectors
is
located
next
to
fan
F11,
on
the
other
side
of
the
sheet
metal
wall
that
separates
the
power
supply
bays
from
the
rest
of
the
SSA.
If
you
are
facing
towards
the
back
of
the
SSA,
the
F11–F13
connectors
are
arranged
as
follows:
‐
F11
connector:
left
connector
‐
F12
connector:
middle
connector
‐
F13
connector:
right
connector
5.
Unwind
the
replacement
fan’s
cables.
6.
Remove
the
cable
clip
from
the
replacement
fan.
See
You
may
discard
the
cable
clip.
7.
With
the
label
side
of
the
replacement
fan
facing
into
the
second
power
supply
bay
(labeled
PS2)
and
the
cable
on
the
left,
slip
the
fan
cable
into
the
rubber
grommet
and
connect
the
cable
to
the
chassis
connector.
See
Figure 3-14 Connecting an F11–F13 Fan (Fan F11 Example)
8.
Position
the
fan
in
the
SSA.
9.
Position
the
cables
of
the
F11–F13
fans
on
top
of
the
fans,
ensuring
that
the
cables
are
not
in
a
position
that
would
cause
the
cables
to
be
pinched
by
the
rear
panel.
10. Reinstall
the
rear
panel
of
the
SSA.
You
can
now
reinstall
the
SSA
in
the
equipment
rack.
1
Fan F11 connector
2
Fan F11
3
Rubber grommet
Содержание SSA-G1018-0652
Страница 2: ......
Страница 12: ...x ...
Страница 16: ...xiv ...
Страница 20: ...Getting Help xviii About This Guide ...
Страница 46: ...Completing the Installation Pin Out Descriptions 2 22 Installation ...
Страница 64: ...Using the OFFLINE RESET Button 3 18 Troubleshooting ...
Страница 68: ...Regulatory Compliance A 4 Specifications ...
Страница 76: ...Management of PoE Power to PDs C 4 About PoE Power over Ethernet ...