background image

Configure the Appliance

3-2 Configuration

6.

Select

 

from

 

the

 

following,

 

highlight

 

OK

,

 

and

 

press

 

Enter

.

static

 

IP

:

 

uses

 

a

 

static

 

IP

 

address

 

to

 

configure

 

Ethernet

DCHP

:

 

uses

 

a

 

DHCP

 

server

 

to

 

configure

 

Ethernet

loopback

:

 

used

 

to

 

set

 

up

 

a

 

loopback

 

connection

 

(modem

 

or

 

no

 

net)

The

 

ENTER

 

IP

 

ADDRESS

 

FOR

 

“your

 

host

 

name”

 

screen

 

appears.

7.

Enter

 

the

 

appliance

 

IP

 

address,

 

highlight

 

OK

,

 

and

 

press

 

Enter

.

The

 

ENTER

 

NETMASK

 

FOR

 

LOCAL

 

NETWORK

 

screen

 

appears.

8.

Enter

 

the

 

appliance

 

netmask,

 

highlight

 

OK

,

 

and

 

press

 

Enter

.

The

 

ENTER

 

GATEWAY

 

ADDRESS

 

screen

 

appears.

9.

Enter

 

the

 

gateway

 

address

 

for

 

your

 

network,

 

highlight

 

OK

,

 

and

 

press

 

Enter

.

 

The

 

USE

 

A

 

NAME

 

SERVER

 

screen

 

appears.

10. If

 

you

 

will

 

be

 

accessing

 

a

 

name

 

server,

 

highlight

 

Yes

 

and

 

press

 

Enter

.

The

 

SELECT

 

NAME

 

SERVER

 

screen

 

appears.

11. Enter

 

the

 

primary

 

name

 

server

 

IP

 

address,

 

highlight

 

OK,

 

and

 

press

 

Enter

.

The

 

CONFIRM

 

NETWORK

 

SETUP

 

screen

 

appears.

12. Verify

 

your

 

information,

 

highlight

 

ACCEPT

,

 

and

 

press

 

Enter

.

 

Press

 

Enter

 

again

 

in

 

the

 

second

 

verification

 

screen

 

to

 

accept.

Basic

 

network

 

configuration

 

is

 

complete.

 

The

 

ENTER

 

MANAGEMENT

 

SERVER

 

IP

 

screen

 

appears.

13. Enter

 

the

 

IP

 

address

 

of

 

the

 

management

 

server,

 

highlight

 

OK,

 

and

 

press

 

Enter

.

The

 

HW

 

CLOCK

 

screen

 

appears.

14. Select

 

the

 

hardware

 

clock

 

setting,

 

and

 

then

 

the

 

timezone

 

configuration.

 

Highlight

 

OK

 

and

 

press

 

Enter

.

The

 

ENABLE

 

SNMP

 

DAEMON

 

screen

 

appears.

15. To

 

monitor

 

the

 

appliance

 

using

 

an

 

SNMP

 

node

 

manager,

 

highlight

 

YES

 

and

 

press

 

Enter

.

The

 

ENTER

 

SYSTEM

 

CONTACT

 

and

 

the

 

ENTER

 

SYSTEM

 

LOCATION

 

screens

 

appear.

16. Enter

 

the

 

system

 

contact

 

and

 

the

 

system

 

location.

 

Highlight

 

OK

 

and

 

press

 

Enter

 

for

 

each

 

screen.

The

 

READ

 

COMMUNITY

 

STRING,

 

WRITE

 

COMMUNITY

 

STRING,

 

SNMP

 

TRAP

 

DESTINATION,

 

and

 

the

 

TRAP

 

COMMUNITY

 

screens

 

appear.

17. Enter

 

the

 

read

 

community

 

string,

 

write

 

community

 

string,

 

SNMP

 

trap

 

destination,

 

and

 

the

 

trap

 

community

 

string.

 

Highlight

 

OK

 

and

 

press

 

Enter

 

for

 

each

 

screen.

18. Configuration

 

is

 

complete.

 

Reboot

 

the

 

appliance.

Note: 

Static IP is recommended; however, you must evaluate your network environment.

Note: 

If you do not have a gateway on your network, leave the field blank and press 

Enter

.

Содержание Sentinel SNS-TAG-HPA

Страница 1: ...Enterasys Sentinel Trusted Access Gateway Appliance SNS TAG HPA SNS TAG LPA Installation Guide P N 9034297 01...

Страница 2: ......

Страница 3: ...0 Minuteman Road Andover MA 01810 2007 Enterasys Networks Inc All rights reserved Part Number 9034297 01 May 2007 ENTERASYS ENTERASYS NETWORKS ENTERASYS ROAMABOUT ENTERASYS MATRIX ENTERASYS SENTINEL L...

Страница 4: ...s A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits...

Страница 5: ...EE Notice In accordance with Directive 2002 96 EC of the European Parliament on waste electrical and electronic equipment WEEE 1 The symbol above indicates that separate collection of electrical and e...

Страница 6: ...is above the relevant threshold of the SJ T 11363 2006 standard This table shows where these substances may be found in the supply chain of Enterasys electronic information products as of the date of...

Страница 7: ...asures Declaration of Conformity Application of Council Directive s 89 336 EEC 73 23 EEC Manufacturer s Name Enterasys Networks Inc Manufacturer s Address 50 Minuteman Road Andover MA USA 01810 Europe...

Страница 8: ...rt including for reasons of error correction or interoperability except to the extent expressly permitted by applicable law and to the extent the parties shall not be permitted by that applicable law...

Страница 9: ...by agree to maintain complete books records and accounts showing i license fees due and paid and ii the use copying and deployment of the Program You also grant to Enterasys and its authorized represe...

Страница 10: ...nforced to the maximum extent permissible Any such invalidity illegality or unenforceability in any jurisdiction shall not invalidate or render illegal or unenforceable such provision in any other jur...

Страница 11: ...ssemble electronically transfer or reverse engineer the Licensed Software or to translate the Licensed Software into another computer language The media embodying the Licensed Software may be copied b...

Страница 12: ...bligation under this Agreement including a failure to pay any sums due to Enterasys or in the event that You become insolvent or seek protection voluntarily or involuntarily under any bankruptcy law E...

Страница 13: ...tes do not allow limitations on how long an implied warranty lasts and some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation and exclusion...

Страница 14: ...xii...

Страница 15: ...2 5 Chapter 3 Configuration Pre Configuration Tasks 3 1 Configure the Appliance 3 1 Changing Trusted Access Gateway Settings 3 3 Changing Basic Network Configuration 3 3 Changing the Management Server...

Страница 16: ...xiv...

Страница 17: ...Agent is required for communication between the TAG appliance and the Lockdown Enforcer appliance Installing the Assessment Agent on the Nessus Server Provides instructions for installing the Enterasy...

Страница 18: ...at could result in personal injury or death due to an electrical hazard Riesgo de electrocuci n Advierte contra una acci n que pudiera resultar en lesi n corporal o la muerte debido a un riesgo el ctr...

Страница 19: ...tached front rack mount brackets One non redundant power supply One power cord U S version Mid mount rack mounting accessory kit One USB flash drive Front Panel Controls and Indicators Figure 1 1 show...

Страница 20: ...N Displays configured appliance parameters on the LCD Appliance IP Address Gateway IP Address Appliance Network Mask Management Server IP Address ENT Displays the installed TAG software version number...

Страница 21: ...wer Supply Specifications Parameter Description Input voltage 100 to 125 Vac 6 A 50 60 Hz 200 to 240 Vac 3 A 50 60 Hz Output voltage 5 V 3 A 25 A 12 V 2 A 28 A 5 V 0 A 0 5 A 12 V 0 A 0 5 A 3 3 V 1 A 2...

Страница 22: ...197 feet below sea level to 4000 meters 13 123 feet above sea level Non Operating humidity 5 to 95 non condensing Acoustic noise Sound Pressure 55 dBA Rackmount in an idle state at typical office amb...

Страница 23: ...que la del ambiente a nivel de habitaci n Por lo tanto debe considerar la posibilidad de instalar el equipo en un entorno compatible con la temperatura ambiente m xima Tma de 40 C 104 F Reduced Air F...

Страница 24: ...problema Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circ...

Страница 25: ...as usadas de acuerdo con las instrucciones Enterasys le recomienda que se ponga en contacto con el departamento de Asistencia t cnica en www enterasys com services support contact si requiere servici...

Страница 26: ...s section describes how to install the TAG appliance into a rack Rack mount options include Front mount Front mount and mid mount Front Mount Figure 2 1 shows the appliance front panel being attached...

Страница 27: ...acement example To attach the appliance to the rack perform the following steps 1 Use the two mounting holes closest to the center of the appliance for more balanced mounting position 2 Use the M4 scr...

Страница 28: ...Rack Mounting 2 6 Installation...

Страница 29: ...iance To configure the appliance to run the Trusted Access Gateway software 1 Login as root with no password and then press Enter You will receive a warning that there is no root password detected and...

Страница 30: ...ress Enter again in the second verification screen to accept Basic network configuration is complete The ENTER MANAGEMENT SERVER IP screen appears 13 Enter the IP address of the management server high...

Страница 31: ...Changing Basic Network Configuration To change basic network configuration settings such as hostname and appliance IP address enter the following command at the appliance CLI opt tag dnetconfig This w...

Страница 32: ...Changing Trusted Access Gateway Settings 3 4 Configuration...

Страница 33: ...uccessfully installed into drive letter Press any key to continue 6 Remove the USB flash drive from your system 7 Insert the USB flash drive into either USB port see Figure 1 1 on the TAG appliance 8...

Страница 34: ...4 2 Upgrading Trusted Access Gateway Software...

Отзывы: