background image

Wireless Switch Configuration Tasks

RBT-8110 Wireless Switch Installation Guide 3-3

quickstart Command Procedure

To

 

run

 

the

 

quickstart

 

command:

1.

Using

 

the

 

null

 

modem

 

cable

 

shipped

 

with

 

the

 

RBT

8100,

 

attach

 

a

 

PC

 

to

 

the

 

RoamAbout

 

wireless

 

switch’s

 

serial

 

console

 

port.

 

Use

 

these

 

modem

 

settings:

 

9600

 

bps,

 

8

 

bits

1

 

stop

No

 

parity

Hardware

 

flow

 

control

 

disabled

2.

Press

 

Enter

 

three

 

times,

 

to

 

display

 

a

 

username

 

prompt

 

(Username:),

 

a

 

password

 

prompt

 

(Password:),

 

and

 

then

 

a

 

command

 

prompt

 

such

 

as

 

the

 

following:

 

RBT-8110-aabbcc>

(Each

 

switch

 

has

 

a

 

unique

 

system

 

name

 

that

 

contains

 

the

 

model

 

number

 

and

 

the

 

last

 

half

 

of

 

the

 

switch’s

 

MAC

 

address.)

3.

Access

 

the

 

enabled

 

level

 

(the

 

configuration

 

level)

 

of

 

the

 

CLI:

RBT-8110-aabbcc> 

enable

4.

Press

 

Enter

 

at

 

the

 

Enter

 

password

 

prompt.

5.

Type

 

quickstart

.

 

The

 

command

 

asks

 

you

 

a

 

series

 

of

 

questions.

 

You

 

can

 

type

 

?

 

for

 

more

 

help.

 

To

 

quit,

 

press

 

Ctrl

+

C

.

 

The

 

following

 

example

 

code

 

accepts

 

the

 

defaults

 

for

 

system

 

name

 

and

 

country

 

code,

 

and

 

does

 

not

 

configure

 

SSIDs,

 

user

 

information,

 

or

 

distributed

 

access

 

points.

RBT-8110-aabbcc# 

quickstart

This will erase any existing config. Continue? [n]: 

y

Answer the following questions. Enter '?' for help. ^C to break out
System Name [RBT-8110]:

RBT-8110-aabbcc

Country Code [US]: 

US

System IP address []: 

182.29.1.250

System IP address netmask []: 2

55.255.255.0

Default route []: 

182.29.1.1

Do you need to use 802.1Q tagged ports for connectivity on the default VLAN? 

[Y/N]: 

y

Specify the port number that needs to be tagged [1-2, <CR> ends config]: 

2

Specify the tagged value for port [2] [<CR> ends config:] 

100

Specify the port number that needs to be tagged [1-2, <CR> ends config]:
Enable WebView [y]: 

y

Admin username [admin]: 

rbtadmin

Admin password [mandatory]: 

letmein

Enable password [optional]: 

enable

Do you wish to set the time? [y]: 

y

Enter the date (dd/mm/yy) []: 

31/03/06

Is daylight saving time (DST) in effect [n]: 

n

Enter the time (hh:mm:ss) []: 

04:36:20

Enter the timezone []: 

EST

Enter the offset (without DST) from GMT for 'PST' in hh:mm [0:0]: 

-5:00

Do you wish to configure wireless? [y]: 

y

Enter a clear SSID to use: 

public

Note: 

Do not attempt to connect a monitor, keyboard, or mouse to the switch. Use only a null 

modem cable connected to the serial console port.

Содержание RoamAbout RBT-8110

Страница 1: ...RoamAbout Wireless Networking RBT 8110 Wireless Switch Installation Guide P N 9034285 01...

Страница 2: ......

Страница 3: ...nuteman Road Andover MA 01810 2006 Enterasys Networks Inc All rights reserved Part Number 9034285 01 November 2006 ENTERASYS ENTERASYS NETWORKS ENTERASYS ROAMABOUT ROAMABOUT ENTERASYS MATRIX LANVIEW M...

Страница 4: ...s for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio le...

Страница 5: ...Equipment WEEE Notice In accordance with Directive 2002 96 EC of the European Parliament on waste electrical and electronic equipment WEEE 1 The symbol above indicates that separate collection of ele...

Страница 6: ...asures Declaration of Conformity Application of Council Directive s 89 336 EEC 73 23 EEC Manufacturer s Name Enterasys Networks Inc Manufacturer s Address 50 Minuteman Road Andover MA USA 01810 Europe...

Страница 7: ...ENTERASYS OR YOUR DEALER IF ANY WITHIN TEN 10 DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT CONTACT ENTERASYS NETWORKS LEGAL DEPARTMENT AT 978 68...

Страница 8: ...LAIMS ALL WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY SATISFACTORY QUALITY FITNESS FOR A PARTICULAR PURPOSE TITLE AND NON INFRINGEMENT WITH...

Страница 9: ...breach of this Agreement 12 WAIVER A waiver by Enterasys of a breach of any of the terms and conditions of this Agreement must be in writing and will not be construed as a waiver of any subsequent bre...

Страница 10: ...viii...

Страница 11: ...n Pre Configuration Tasks 3 1 Wireless Switch Configuration Tasks 3 1 Using the CLI quickstart Command 3 1 quickstart Command Procedure 3 3 Configuring RoamAbout Wireless Switches Using RASM 3 5 Preco...

Страница 12: ...x...

Страница 13: ...I commands that you enter on a RoamAbout Switch RAS to configure and manage the Mobility System wireless LAN WLAN RoamAbout Switch Manager Users Guide Explains how to plan configure deploy and manage...

Страница 14: ...jury or death due to an electrical hazard Riesgo de electrocuci n Advierte contra una acci n que pudiera resultar en lesi n corporal o la muerte debido a un riesgo el ctrico Elektrische Spannung Warnu...

Страница 15: ...ttached front rack mount brackets One non redundant power supply One power cord U S version One null modem cable Mid mount rack mounting accessory kit Front Panel Controls and Indicators Figure 1 1 sh...

Страница 16: ...A continuous amber light indicates a link between the system and the network to which it is connected A blinking amber light indicates network activity Status Power A continuous blue light indicates...

Страница 17: ...le 1 4 A Keyboard mouse connectors C Power supply B Video connector D Power connector Table 1 3 Power Supply Specifications Parameter Description Input voltage 100 to 125 Vac 6 A 50 60 Hz 200 to 240 V...

Страница 18: ...perature 40 C to 70 C 104 F to 158 F Altitude 60 meters 197 feet below sea level to 4000 meters 13 123 feet above sea level Non Operating humidity 5 to 95 non condensing Acoustic noise Sound Pressure...

Страница 19: ...la del ambiente a nivel de habitaci n Por lo tanto debe considerar la posibilidad de instalar el equipo en un entorno compatible con la temperatura ambiente m xima Tma de 40 C 104 F Reduced Air Flow...

Страница 20: ...este problema Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch...

Страница 21: ...r as usadas de acuerdo con las instrucciones Enterasys le recomienda que se ponga en contacto con el departamento de Asistencia t cnica en www enterasys com services support contact si requiere servic...

Страница 22: ...is section describes how to install the RBT 8110 into a rack Rack mount options include Front mounting Front mount and mid mount Front Mount Figure 2 1 shows the RBT 8110 front panel being attached to...

Страница 23: ...ched and a mid mount placement example To attach the chassis to the rack perform the following steps 1 Use the two mounting holes closest to the center of the chassis for more balanced mounting positi...

Страница 24: ...Rack Mounting 2 6 Installation...

Страница 25: ...sks Wireless Switch Configuration Tasks Once the wireless switch is physically installed and powered on you can set up its configuration This section describes two ways to configure a newly installed...

Страница 26: ...te generated if you type usernames and passwords for users of unencrypted SSIDs One of the questions the script asks is the country code For a list of valid country codes refer to either the RoamAbout...

Страница 27: ...SSIDs user information or distributed access points RBT 8110 aabbcc quickstart This will erase any existing config Continue n y Answer the following questions Enter for help C to break out System Name...

Страница 28: ...o exit Do you wish to configure access points y y Enter a port number 1 2 on which an AP resides cr to exit 2 Enter AP model on port 2 RBT 1602 Enter a port number 1 2 on which an AP resides cr to exi...

Страница 29: ...ertificates in the Connection Security area 6 Click Save 7 Open the network plan for the site or create a new one 8 Access the Create Mobility Exchange wizard a Select the Configuration toolbar option...

Страница 30: ...the switch to use the MSS DHCP client to obtain this information from a DHCP server in the local network where the switch will be deployed Alternatively you can statically configure the information Th...

Страница 31: ...nown name wlan config srv RBT 8110 set ip alias wlan config srv 172 16 22 84 6 Enable the auto config option RBT 8110 set auto config enable 7 Save the configuration changes RBT 8110 save config 8 Res...

Страница 32: ...lso has a local DNS server However the local DNS domain name is different from the corporate DNS domain name where the RASM server is located The static DNS configuration on the switch overrides the D...

Страница 33: ...dant PoE DHCP A Distributed AP uses IP for communication and relies on DHCP to obtain IP parameters Therefore DHCP services must be available on the subnet that the AP is connected to DHCP must provid...

Страница 34: ...Preparing the Network for Distributed Access Points 3 10 Configuration...

Страница 35: ...Input voltage 1 3 Install rack 2 1 Intended audience xi K Kit contents 1 1 N Notices BSMI EMC iv Class A ITE ii EMC iii FCC ii General ii Industry Canada ii Product Safety ii VCCI iv O Output voltage...

Страница 36: ......

Отзывы: