Running H/F 2
1-4 RBT-8110 Wireless Switch Overview
Environmental Specifications
Ensure
that
the
environmental
specifications
are
within
the
ranges
described
in
Table 1
‐
5
.
Table 1-5 Environmental Specifications
Parameter
Description
Operating Temperature
0°C to 50°C (50°F to 95°F) with the maximum rate of change not to
exceed 10°C per hour
Non-Operating Temperature
40°C to +70°C (104°F to 158°F)
Altitude
-60 meters (-197 feet) below sea level to 4000 meters (13,123 feet)
above sea level
Non-Operating humidity
5% to 95%, non-condensing
Acoustic noise
Sound Pressure: 55 dBA (Rackmount) in an idle state at typical office
ambient temperature (23°C +/- 2°C)
Sound Power: 7.0 BA in an idle state at typical office ambient
temperature (23°C +/- 2 °C)
Operating Shock
No errors with a half sine wave shock of 2G (with 11 millisecond
duration)
ESD
+/-15k V per Intel Environmental test specification
System Cooling
Requirement in BTU/Hr.
1826 BTU/hour