Overview of DFE Module Shutdown Procedure
4-10 Troubleshooting
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch
To
reset
a
DFE
module
without
it
performing
an
orderly
shutdown
routine,
press
and
hold
the
OFFLINE/RESET
switch
for
approximately
6
seconds.
Pulling
any
DFE
module
out
of
the
chassis
before
it
has
been
shut
down
is
not
recommended.
The
only
safe
time
to
pull
a
module
out
of
the
chassis
is
after
the
completion
of
a
shutdown
and
the
management
LED
is
flashing
amber/off.
Caution:
This method of shutting down a DFE module is not recommended except as a
last resort, because all processes currently running on the module will be interrupted
resulting in loss of frames.
Precaución:
No se recomienda utilizar este método para apagar los módulos DFE- Gold.
Recurra a él sólo como último recurso, puesto que interrumpe todos los procesos del
módulo en funcionamiento, lo que podría resultar pérdidas de frames.