background image

Enterasys Matrix

DFE-Platinum Series

Hardware Installation Guide

7H4385-49

P/N 9033987-05

Содержание Matrix 7H4385-49

Страница 1: ...Enterasys Matrix DFE Platinum Series Hardware Installation Guide 7H4385 49 P N 9033987 05...

Страница 2: ......

Страница 3: ...Networks Inc 50 Minuteman Road Andover MA 01810 2007 Enterasys Networks Inc All rights reserved Part Number 9033987 05 July 2007 ENTERASYS NETWORKS ENTERASYS MATRIX LANVIEW MATRIX ENTERASYS NETSIGHT...

Страница 4: ...ss A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruit...

Страница 5: ...WEEE NOTICE In accordance with Directive 2002 96 EC of the European Parliament on waste electrical and electronic equipment WEEE 1 The symbol above indicates that separate collection of electrical an...

Страница 6: ...is above the relevant threshold of the SJ T 11363 2006 standard This table shows where these substances may be found in the supply chain of Enterasys electronic information products as of the date of...

Страница 7: ...ser adjustment Class 1 Laser transceivers comply with the following safety standards 21 CFR 1040 10 and 1040 11 U S Department of Health and Human Services FDA IEC Publication 825 International Electr...

Страница 8: ...xus House Newbury Business Park London Road Newbury Berkshire RG14 2PZ England Conformance to Directive s Product Standards EC Directive 89 336 EEC EN 55022 EN 61000 3 2 EN 61000 3 3 EN 55024 EC Direc...

Страница 9: ...F YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT ENTERASYS IS UNWILLING TO LICENSE THE PROGRAM TO YOU AND YOU AGREE TO RETURN THE UNOPENED PRODUCT T...

Страница 10: ...st or iii if the direct product of the technology is a complete plant or any major component of a plant export to Country Groups D 1 or E 2 the direct product of the plant or a major component thereof...

Страница 11: ...edge and agree that any breach of Sections 2 4 or 9 of this Agreement by You may cause Enterasys irreparable damage for which recovery of money damages would be inadequate and that Enterasys may be en...

Страница 12: ...x...

Страница 13: ...tional Interface Module 2 2 10BASE T Network 2 2 100BASE TX Network 2 3 Chapter 3 Installation Installation Site Requirement 3 2 Unpacking the DFE Module 3 2 Installing Optional Network Expansion Modu...

Страница 14: ...wn Procedure Using OFFLINE RESET Switch 4 10 Appendix A Specifications DFE Module Specifications A 1 COM Port Pinout Assignments A 2 Regulatory Compliance A 3 Appendix B Mode Switch Settings and Optio...

Страница 15: ...ble 3 21 3 10 Connecting a VT Series Terminal 3 22 3 11 Connecting to a Modem 3 23 3 12 Matrix DFE Startup Screen Example N7 Chassis 3 27 4 1 LANVIEW LEDs 4 2 4 2 OFFLINE RESET Switch 4 9 B 1 Mode Swi...

Страница 16: ...xiv...

Страница 17: ...efers to the 7H4385 49 unless otherwise noted Network expansion module NEM refers to an optional uplink card installed on the main logic board and accessible through the option slot of the 7H4385 49 P...

Страница 18: ...ble specifications Unlike the Enterasys Matrix DFE Platinum Series Configuration Guide and the Matrix N Series N POE Power System Installation Guide the Cabling Guide is not listed alphabetically on t...

Страница 19: ...uipment Precauci n Contiene informaci n esencial para prevenir da ar el equipo Achtung Verwei t auf wichtige Informationen zum Schutz gegen Besch digungen Warning Warns against an action that could re...

Страница 20: ...tion of your network environment for example layout and cable type Network load and frame size at the time of trouble if known The device history for example have you returned the device before is thi...

Страница 21: ...sed in the DFE module some features described in this document may not be supported Refer to the Release Notes shipped with the DFE module to determine which features are supported For information abo...

Страница 22: ...gabit Ethernet connectivity Integrated Services Design that reduces the number type of modules required simplifies network design and lowers entry cost Port and User Based Policy and Multilayer Packet...

Страница 23: ...rate in either half duplex or full duplex mode of operation The duplex mode can be determined by either auto negotiation or manual configuration The DFE module ports can be configured to provide a hig...

Страница 24: ...option slot 4 CPU LED 10 48 Vdc 20 A Max Optional Power Input 5 PoE LED connector 6 GROUP SELECT switch 11 Ports 1 48 10 100 Mbps through RJ45s 1X G R O U P 1 G R O U P 2 11X 13X 23X OFFLINE RESET COM...

Страница 25: ...ided through the RJ45 COM Communication port on the front panel using a VT100 terminal or a VT100 terminal emulator Switch Configuration Using WebView Enterasys Networks HTTP based Web management appl...

Страница 26: ...d by each Switch or Router In general Classification Rules are applied to the networking infrastructure at the network edge ingress point Network Services are logical groups of Classification Rules th...

Страница 27: ...operate on 10 Mbps 100 Mbps or 1000 Mbps Ethernet full duplex ports Thus the network administrator can combine a group of five 100 Mbps ports into a logical link trunk that functions as a single 500...

Страница 28: ...talled and to follow the module placement rules described in Module Placement and Installation Rules on page 3 4 FTM Bridge Function and Optional Interface Module The 7H4385 49 DFE Platinum module doe...

Страница 29: ...for the devices to operate at 100 Mbps The fixed front panel ports also support the 802 3af 2003 standard for Power over Ethernet PoE power sourcing applications over existing cabling For more informa...

Страница 30: ...100BASE TX Network 2 4 Network Requirements...

Страница 31: ...durch ausgebildetes und qualifiziertes Personal vorgenommen werden Important Notice Read the Release Notes shipped with the DFE module to check for any exceptions to the supported features and operati...

Страница 32: ...rasys Networks if there are any signs of damage Refer to Getting Help on page xviii for details Warning Install this module in a Matrix E7 N1 N3 N5 or N7 chassis that has been installed in a Restricte...

Страница 33: ...st 6x1xx second 6x2xx third 6x3xx and fourth 7xxxxx generation modules into the same Matrix E7 chassis FTM1 and FTM2 Connectivity The Matrix E7 6C107 chassis has backplanes referred to as FTM1 and FTM...

Страница 34: ...sis support only DFE Series modules and there are no particular rules for installing modules Matrix E7 Chassis Module Placement Depending on the modules being installed in the Matrix E7 chassis and to...

Страница 35: ...dalone mode Example 4 Figure 3 1 D Shows chassis slots 1 through 5 populated with a mix of 6x1xx 6x2xx and 6x3xx modules and only third generation modules in slots 6 and 7 In this module arrangement t...

Страница 36: ...s will not communicate with any other modules in the chassis Rule In this example there must be at least one 6x3xx series module and a bridging module in any of the slots 1 through 5 to enable communi...

Страница 37: ...rom Electrostatic Discharge ESD Caution Failure to observe static safety precautions could cause damage to the module Follow static safety handling rules and wear the antistatic wrist strap Do not cut...

Страница 38: ...ckplane connectors Ensure that the top lever lines up with the desired slot number located on the front panel of the chassis Refer to Figure 3 2 Precauci n Para evitar que se da en los conectores del...

Страница 39: ...bleshooting details Caution Due to the amount of force needed to properly seat the module connectors into the backplane connectors it is best to apply force to the end of the levers to insert or eject...

Страница 40: ...s 5 Upper lower locking tabs in proper open position 6 Upper lower locking tab in closed position 1 SERIES E7 4 5 6 7 2 3 50 60Hz LINE 100 125V 12A 200 240V 6A 50 60Hz LINE 100 125V 12A 200 240V 6A AC...

Страница 41: ...ca es posible que el m dulo se da e Siga los consejos de seguridad para la manipulaci n del producto y no olvide utilizar la pulsera antiest tica No corte la bolsa antiest tica para sacar el m dulo Te...

Страница 42: ...ls Caution Due to the amount of force needed to properly seat the module connectors into the backplane connectors it is best to apply force to the end of the levers to insert or eject the module Other...

Страница 43: ...locking tab shown in closed position 3 Module card 7 FTM2 and power backplane connectors 4 Metal back panel 7C203 1 REDUNDANCY PWR 100 125V 12 0A 200 240V 6 0A 50 60 Hz 7C203 1 REDUNDANCY PWR 100 125V...

Страница 44: ...N POE Power System Advertencia El modulo DFE es embarcado con una cubierta sobre su conector de poder opcional de 48 Vdc No remover esta cubierta cuando el modulo DFE es instalado en un chassis N5 Est...

Страница 45: ...e regardless if the connection is to another network device or a workstation The RJ45 fixed front panel connectors of the 7H4385 49 also support PoE compliant connections to PDs powered devices that r...

Страница 46: ...gments press the GROUP SELECT button for less than one second see Figure 3 4 to step to the group of interest Groups 1 through 4 Caution To prevent damage to the equipment do not connect the PoE suppo...

Страница 47: ...the twisted pair segment is on and properly connected to the segment e Verify that the RJ45 connectors on the twisted pair segment have the proper pinouts and check the cable for continuity Typically...

Страница 48: ...uts Connections Between Hub Devices 1 RJ45 device port 3 RJ45 to RJ45 straight through cable 2 Other device port 4 RX RX and TX TX connections These connections must share a common color pair 1 RJ45 d...

Страница 49: ...ough 3 above until all connections have been made Verifying PoE Port Status If a PD is connected to the 7H4385 49 RJ45 port ensure that there is power at the RJ45 port as follows 1 Press on the GROUP...

Страница 50: ...nnect products equipped with an RJ45 COM port to an IBM or compatible PC running a VT series emulation software package Using a UTP straight through cable and an RJ45 to DB25 female adapter you can co...

Страница 51: ...ect a VT Series terminal to an Enterasys Networks DFE module COM port Figure 3 10 use a UTP straight through cable with RJ45 connectors and an RJ45 to DB25 female adapter and proceed as follows 1 Conn...

Страница 52: ...rix DFE Platinum Series Configuration Guide for further information Figure 3 10 Connecting a VT Series Terminal Connecting to a Modem To connect a modem to an Enterasys Networks DFE module COM port Fi...

Страница 53: ...he switch remotely To accomplish this you must configure your PC VT emulation package with the following parameters 6 When these parameters are set the Local Management password screen will display Re...

Страница 54: ...Signal Assignments COM Port Adapter Wiring and Signal Diagram RJ45 DB9 Pin Conductor Pin Signal 1 Blue 2 Receive RX 4 Red 3 Transmit TX 5 Green 5 Ground GRD 2 Orange 7 Request to Send RTS 6 Yellow 8 C...

Страница 55: ...en 7 Ground GRD 2 Orange 20 Data Terminal Ready Modem Port Adapter Wiring and Signal Diagram RJ45 DB25 Pin Conductor Pin Signal 1 Blue 2 Transmit TX 2 Orange 8 Data Carrier Detect DCD 4 Red 3 Receive...

Страница 56: ...st Time Log In Using a Console Port Connection Start the Command Line Interface CLI from the module s local console port as follows 1 Connect a terminal to the local console port as described in Conne...

Страница 57: ...he Enterasys Matrix DFE Platinum Series Configuration Guide is available online at http www enterasys com support manuals If you require assistance contact Enterasys Networks using one of the methods...

Страница 58: ...gin prompt enter your administratively assigned user name and press ENTER 2 At the Password prompt enter your password and press ENTER The notice of authorization and the Matrix prompt displays as sho...

Страница 59: ...ement functions for all DFE modules in the chassis The Management Module handles all IP requests to the chassis IP address such as but not limited to PING Telnet SNMP HTTP The Management Module also h...

Страница 60: ...in an N5 chassis or is receiving 48 Vdc from an external N POE Power System to support connections to PDs Powered Devices you can view the power status indications on the RX and TX LEDs However only o...

Страница 61: ...LEDs LED Color State Recommended Action MGMT Off Off This DFE module is NOT the Management Module None Green Solid This module is the designated Management Module None Amber Flashing This is a tempora...

Страница 62: ...Flashing Link present port enabled traffic is being received by the interface None Red Blinking Indicates collisions This indication is only supported on 10 100 ports Contact Enterasys Networks for te...

Страница 63: ...ircuits 3 Contact Enterasys Networks for technical support Red Off Port is off due to PoE power management Port may be turned off due to priority or other administration configuration None Off Off Por...

Страница 64: ...ent Password screen Incorrect terminal setup Refer to the Enterasys Matrix DFE Platinum Series Configuration Guide for proper setup procedures Improper console cable pinouts Refer to Appendix A for pr...

Страница 65: ...o the Enterasys Matrix DFE Platinum Series Configuration Guide for information about Host Port and management VLAN configuration No link to device Verify that all network connections between the netwo...

Страница 66: ...ecommended Last Resort Shutdown Procedure Using OFFLINE RESET Switch on page 4 10 User parameters IP address device and module name etc were lost when the module power was cycled the front panel OFFLI...

Страница 67: ...to restart or remove the DFE module from the chassis When a controlled shutdown is initiated from the OFFLINE RESET switch you have 60 seconds from the time the CPU starts flashing amber off until th...

Страница 68: ...ly safe time to pull a module out of the chassis is after the completion of a shutdown and the management LED is flashing amber off Caution This method of shutting down a DFE module is not recommended...

Страница 69: ...9 DFE module For information about Refer to page DFE Module Specifications A 1 COM Port Pinout Assignments A 2 Regulatory Compliance A 3 Table A 1 7H4385 49 Specifications Item Specification Ports 1 t...

Страница 70: ...ime Between Failures MTBF For the MTBF hours for this product refer to the MTBF web site at URL http www enterasys com support mtbf Environmental Operating Temperature 5 C to 40 C 41 F to 104 F Storag...

Страница 71: ...ompatibility EMC requirements listed in Table A 3 Table A 3 Compliance Standards Regulatory Compliance Standards Safety UL 60950 CSA C22 2 No 60950 73 23 EEC EN 60950 IEC 60950 EN 60825 21 CFR 1040 10...

Страница 72: ...Regulatory Compliance A 4 Specifications...

Страница 73: ...aining Access to Memory Modules B 4 Caution An antistatic wrist strap is required to perform the procedures in this appendix Use the antistatic wrist strap shipped with chassis when performing any of...

Страница 74: ...e the factory default settings or reenter your own parameters Switch 8 Clear Admin Password Changing the position of this switch clears the admin password and restores the factory default password on...

Страница 75: ...es If you have questions concerning the replacement of either memory module refer to Getting Help on page xviii for details on how to contact Enterasys Networks Figure B 2 shows the DIMM and DRAM SIMM...

Страница 76: ...U P 4 37X 47X 38X 48X 1 2 3 4 48V 20A MAX OPTIONAL POWER INPUT G R O U P 1 1X 7H4385 49 FAST ENET DFE Electrical Hazard To prevent exposure to an energy hazard in a 7H4385 49 connected to an external...

Страница 77: ...f you need to replace the DIMM proceed to DIMM Replacement Procedure on page B 10 If you are replacing the DRAM SIMM proceed to DRAM SIMM Replacement Procedure on page B 7 Warning The safety cover pro...

Страница 78: ...rews 7 4 Standoff spacer screwed to standoff under the NEM 1 2 3 4 5 6 1 2 3 4 5 6 7G 6MGBIC A 1X G R O U P 1 G R O U P 2 11X 13X 23X OFFLINE RESET COM CPU MGMT GROUP SELECT GROUP 1 2 3 4 5 6 7 8 9 10...

Страница 79: ...Optional Network Expansion Module Caution Observe all Electrostatic Discharge ESD precautions when handling sensitive electronic equipment Precauci n Al trabajar con equipos electr nicos sensibles to...

Страница 80: ...Now you have access to the DRAM SIMM To replace the DRAM SIMM proceed to Removing the DRAM SIMM Removing the DRAM SIMM To remove the DRAM SIMM refer to Figure B 5 and proceed as follows 1 Refer to Fi...

Страница 81: ...MM alignment notches and the tabs on the two connector arms lock the DRAM SIMM into place 3 Reinstall the network expansion module Refer to Installing the Network Expansion Module NEM on page B 11 for...

Страница 82: ...afety cover to the standoffs on the main PC board 2 Locate the DIMM connector on the main PC board Refer back to Figure B 2 for the DIMM location on the 7H4385 49 3 Push the connector arms away from t...

Страница 83: ...afety Cover on page B 13 for instructions Figure B 8 Installing the DIMM Installing the Network Expansion Module NEM Refer to Figure B 9 and proceed as follows 1 Position the NEM so its front panel is...

Страница 84: ...e main board Screw in the standoff but do not tighten screws at this time 5 Tighten the two coverplate screws first then the standoff 1 NEM 3 NEM connectors 5 Coverplate screws 2 2 Front panel 4 Main...

Страница 85: ...ompletes the safety cover installation Warning The safety cover protects you from exposure to an energy hazard in excess of 240 Volt Amperes Never operate the DFE module without the safety cover insta...

Страница 86: ...cover 2 Screws 7 3 Standoff 7 1 2 3 4 5 6 1 2 3 4 5 6 7G 6MGBIC A 1X G R O U P 1 G R O U P 2 11X 13X 23X OFFLINE RESET COM CPU MGMT GROUP SELECT GROUP 1 2 3 4 5 6 7 8 9 10 11 12 POE 12 X 14X 24X G R...

Страница 87: ...wer supply current and the other pair provides a path for the return current While several proprietary legacy implementations of PoE have been deployed by LAN equipment vendors in 2003 the IEEE publis...

Страница 88: ...atus signals indicate the presence and operating state of each Matrix N POE Power System power supplies This 48 Vdc Optional Power Input interface is not fused as the N PoE Power System has a circuit...

Страница 89: ...ault RX TX Status Mode to the PoE Port Status Mode using the DFE module front panel GROUP SELECT switch The switch operation and a description of how to use the LED indications are described in Using...

Страница 90: ...Overview C 4 About PoE Power over Ethernet...

Страница 91: ...procedures for B 3 E Electromagnetic Compatibility EMC requirements A 3 F FTM bridge function introduction to 2 2 G Getting Help instructions for xviii GROUP SELECT button use of the 4 2 I Installatio...

Страница 92: ...14 PoE port status viewing of 4 2 R Receive LEDs viewing of 4 2 Regulatory Compliance A 3 Related manuals obtaining xvi Required tools B 1 S Safety requirements A 3 Specifications A 1 7H4385 49 A 1 St...

Отзывы: