Enterasys Wireless Outdoor AP Cables
Enterasys Wireless Outdoor AP Installation Guide
3-3
Enterasys Wireless Outdoor AP Cables
Cable Specification
The
following
table
lists
the
requirements
for
a
cable
depending
on
the
use
case.
Warning: Cat. Nos. EAP-Wx-yy-zx (Canadian installation only):
•
TC cable type and manufacturer shall be specified: Listed (QPOR), Type JZ-604 TC
manufactured by Helukabel GmbH.
•
The TC cable for the power supply must be installed in areas of industrial establishments that
are inaccessible to the public and in a manner that meets the requirements in Rule 12- 2202(2)
of the CEC: Installed in conduit, other suitable raceway, or direct buried, when not in cable tray.
Provided with mechanical protection where subject to damage either during or after
installation.Installed only where qualified persons service the installation.
When operated in potential hazardous areas:
WARNING - Explosion Hazard – Do not disconnect while circuit is live unless area is known to
be non-hazardous
WARNING - Explosion Hazard – Substitution of components may impair suitability for Class I,
Division 2 or Zone 2
Table 3-1
Cable Specification
Application
Specification
Power supply adapter 110-230 V AC
•
Round cable cross-section with 6 to 8 mm diameter.
•
Three-core cable with 0.5-1.5 mm cross-section of the
individual cores.
•
Permitted tensile load at least 100 N.
Ethernet
IE FC TP Standard Cable GP 2 x 2 (type A)
Order no. 6XV1 840-2AH10
IE TP Torsion Cable 2 x 2 (type C)
Order no. 6XV1 870-2F
IE FC TP Trailing Cable 2 x 2 (type C)
Order no. 6XV1 840 3AH10
Warning:
If temperatures in excess of 70 degrees occur on the cable or at the housing socket, or
the temperature at the branching points of the cables exceeds 80 degrees, special measures need
to be taken.
If the device is operated at an ambient temperatures of 55 degrees C – 70 degrees C, make sure
that you use cables with a permitted ambient temperature of at least 90 degrees C.
Содержание AP2650
Страница 1: ...P N 9034543 01 Enterasys Wireless Outdoor Access Points Installation Guide AP2650 AP2660 ...
Страница 2: ......
Страница 10: ...viii ...
Страница 14: ...Safety Information xii About This Guide ...
Страница 46: ...Optional Third party External Antennas 4 6 Technical Specifications ...
Страница 54: ...Index 2 ...
Страница 56: ...7 2 ...
Страница 58: ...1 2 ...