Enterasys Wireless Outdoor AP Installation Guide
3-1
3
Connecting Cables to the Enterasys Wireless
Outdoor AP
Safety Notices
Notes on Lightning Protection
A
suitable
lightning
conductor
is
available
in
the
range
of
accessories
for
the
Enterasys
Wireless
Outdoor
AP
(Lightning
Protector
LP798
‐
1N,
Order#
6GK5798
‐
2LP00
‐
2AA6
from
Siemens
A&D).
Safety Extra Low Voltage
Warning:
Antennas installed outdoors must be within the area covered by a lightning protection
system. Make sure that all conducting systems entering from outdoors can be protected by a
lightning protection potential equalization system.When implementing your lightning protection
concept, make sure you adhere to the VDE 0182 or IEC 62305 standard.
Warning:
Installing
this
lightning
protector
between
an
antenna
and
an
Enterasys
Wireless
Outdoor
AP
is
not
adequate
protection
against
a
lightning
strike.
The
LP798
‐
1N
lightening
protector
only
works
within
the
framework
of
a
comprehensive
lightning
protection
concept.
If
you
have
questions,
consult
a
qualified
specialist
company.
Note:
The requirements of EN61000-4-5, surge immunity tests on power supply lines, are met only
when a Blitzductor is used with 12 V DC and 48 V DC:
• 12 V DC: VT AD 24V type no. 918 402
• 48 V DC: Type no. 919 545 and 919 506 (holder)
Manufacturer: DEHN+SÖHNE GmbH+Co.KG Hans Dehn Str.1 Postfach 1640 D 92306 Neumarkt,
Germany.
Warning:
Enterasys Wireless Outdoor APs are designed for operation with a directly connectable
safety extra-low voltage or with the power supply adapters available as accessories (available only
for Enterasys Wireless Outdoor AP devices). Therefore, only safety extra-low voltage (SELV) with
limited power source (LPS) complying with IEC950/EN60950/VDE0805 may be connected to the
power supply terminals (exception: Power supply adapter for 110 - 230 V AC for the Enterasys
Wireless Outdoor AP).
The power supply unit to supply the Enterasys Wireless Outdoor AP must comply with NEC Class 2
(requirements of class 2 for power supply units of the "National Electrical Code, table 11 (b)") or
SELV with LPS (Limited Power Source) EN 60950-1. If the power supply is designed redundantly
(two separate power supplies), both power supplies must meet these requirements.
Exception:
•
Power supply with PELV (according to VDE 0100-410 or IEC 60364-4-41) is also possible if the
generated rated voltage does not exceed the voltage limits 25 V AC or 60 V DC.
Содержание AP2650
Страница 1: ...P N 9034543 01 Enterasys Wireless Outdoor Access Points Installation Guide AP2650 AP2660 ...
Страница 2: ......
Страница 10: ...viii ...
Страница 14: ...Safety Information xii About This Guide ...
Страница 46: ...Optional Third party External Antennas 4 6 Technical Specifications ...
Страница 54: ...Index 2 ...
Страница 56: ...7 2 ...
Страница 58: ...1 2 ...